background image

 

 

12 YEAR LIMITED WARRANTY

 

As of  November 2022

 

 

 

 

This  Residential    Water  Conditioner  is  warranted  for  a  period  of 

one  year

  from  date  of 

purchase  by  first  user  against  defects  in  materials  and  workmanship.    In  addition,  the  complete 

control valve is warranted for 

five  years.

  The control valve body (excluding internals and electrical 

parts) is warranted for 

six    years.

  The mineral tank, plastic brine tank or cabinet tank (excluding 

mineral) is warranted against rust, corrosion or bursting for a period of 

twelve  years

 from date of 

manufacture.    Except,  as  specifically  set  forth  in  this  paragraph,  Master  Water  Conditioning 

Corporation makes no other warranties, express or implied.

 

 

 

This warranty shall be void if the conditioner is moved from the place of original installation, 

or if damage is caused by misuse, misapplication, accident, freezing, flood, fire or if not installed in 

accordance with instructions furnished by Master Water Conditioning Corporation.

 

 

 

This  warranty  shall  be  void  in  the  event  of  damages  from  external  sources  or  where  the 

conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature 

greater than 100 degrees F. or less than 32 degrees F.   Incidental costs or consequential damages are 

not covered by this warranty.

 

 

 

 All defective parts shall be returned prepaid to Master Water Conditioning Corporation for 

inspection.  

Master shall not be liable for labor charges other than Master factory repairs

.

 

 

 

This warranty gives you specific legal rights, and you may have other rights which vary from 

state to state.  Some states do not allow limitations on duration of implied warranties or exclusion of 

incidental or consequential damages, so the above limitations may not apply to you.

 

 

 

All  claims  must  be  submitted in  writing  to  Master Water  Conditioning  Corporation at  224 

Shoemaker Road, Pottstown, Pennsylvania 19464 within thirty (30) days from the discovery of the 

defect.    Master  Water  Conditioning  Corporation  thereafter  will  correct  defective  parts  and 

workmanship or rusting, corrosion or bursting within sixty (60) days.

 

 

 

 

 

 

 

 

 

 

 

224 Shoemaker Rd. Pottstown, Pa. 19464

 

MASTER

Water Conditioning Corp.

Summary of Contents for Clarifier MCA Series

Page 1: ...MCA Clarifier Series Residential Filters 2022 MASTER Water Conditioning Corp Installation and Operation Manual...

Page 2: ...Loading 2 Clarifier Control Valve 2 4 Service and Drain Piping 4 5 Electrical Supply 6 Filling Filter with Water 6 Control Valve Timer Settings 7 Final Check 7 Default Timer Display and Manual Regene...

Page 3: ...CC 10 N A 1 5 CF Carbon Centaur MCA AC ACC 13 N A 2 0 CF Carbon Centaur MCA AN 10 N A 1 0 CF Calcite 0 5 CF NS Mix MCA AN 13 N A 2 0 CF Calcite MCA FE 10B N A 1 5 CF Birm MCA FE 13B N A 2 0 CF Birm MC...

Page 4: ...media provided with the unit into the top of the tank Model Gravel 1 Sand 0 Sand 45 Sand 0 Sand Philterkol MCA MM 10 N A 20 lbs 12 lbs 37 lbs 25 lbs 19 lbs MCA MM 13 N A 25 lbs 16 lbs 50 lbs 35 lbs 2...

Page 5: ...rection two threaded connections for the tail piece kit and two o ring seal connections with nuts for the control valve Align the insert connection ends with o ring seals and nuts to the inlet and out...

Page 6: ...alve or bypass If Schedule 80 PVC is used make sure to follow the proper primer and solvent instructions 3 The drain line connection is npt or optional 5 8 OD and is located on the top left of the val...

Page 7: ...orp Well Tank NOTE All Master Water Conditioners must be installed after the well tank or water meter if its public water supply Master Water Conditioner Air Gap Drain Untreated TYPICAL PIPING LAYOUT...

Page 8: ...or three seconds until the drive motor starts When the drive motor stops the display will read C1 backwash position 3 Open the inlet ball valve a turn of its full open position to allow water to enter...

Page 9: ...egen and the hour will be blinking 1 Use the UP or DOWN arrows to adjust hour 2 Press the CLOCK button 3 Press the UP or DOWN arrows to adjust the minutes 4 Press the CLOCK button Regeneration Frequen...

Page 10: ...8...

Page 11: ...9...

Page 12: ...Water Quality When Unit is in Service Position Cause Solution The bypass valve is open or defective Insure that the bypass valve is in the service position Excessive water usage Set the timer to rege...

Page 13: ...nlet piping Distributor pipe is plugged Clean or replace the distributor pipe Problem Control Valve Cycles Continuously Cause Solution Defective timer circuit board Replace the circuit board Problem T...

Page 14: ...ap assembly Replace drive gear or drive cap assembly Broken piston retainer Replace piston retainer Broken main or regenerate piston Replace main or regenerate piston Problem Control valve does not re...

Page 15: ...or mechanical stall Defective motor damaged wiring poor wire connection or mechanical component failure E3 Motor running too long or timeout during piston relocating Damaged wiring poor wire connecti...

Page 16: ...14...

Page 17: ...15...

Page 18: ...16...

Page 19: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Page 20: ...P1 8 50 8 4 1 99 P2 8 70 10 6 1 99 P3 12 70 12 8 1 99 P4 10 50 Skipped 8 1 99 P5 4 50 Skipped 4 1 99 P6 12 6 Skipped 12 1 99 P7 6 Skipped Skipped 4 Skipped P8 10 Skipped Skipped 6 Skipped P9 14 Skippe...

Page 21: ...LOCK CLOCK CLOCK REGENERATE NOW PRESS BOTH ARROWS FOR 4 SECONDS MOTOR WILL START REGENERATE TONIGHT PRESS BOTH ARROWS FOR 1 SECOND MANUAL REGENERATION AND SIMULTANEOUSLY ADVANCE THROUGH EACH REGENERAT...

Page 22: ...Regen d1 Do not Regen OR d2 Regen Regen d2 Do not Regen CHOOSE REGEN DAY OF WEEK MONDAY CONTINUE THROUGH d7 OR Display Day of Week D1 Sunday D2 Monday D3 Tuesday D4 Wednesday D5 Thursday D6 Friday D7...

Page 23: ...SECONDS 1 Regen Hour SET HOUR OF DAY FOR REGENERATION 4 Days to Regen SET DAYS BETWEEN REGENERATIONS 1 99 DAY OPTION CLOCK AND OR OR CLOCK 00 Regen Minutes SET MINUTES OF DAY FOR REGENERATION OR CLOC...

Page 24: ...Error Codes...

Reviews: