SAFETY INSTRUCTIONS
8
IMPORTANT SAFETY
INSTRUCTIONS (CONT.)
15. A green coloured terminal or a terminal marked G, GR, Ground, Grounding or the
symbol shown in Figure 14.1 of UL1563 is located inside the supply terminal box or
compartment. To reduce the risk of electric shock, this terminal must be connected to
the grounding means provided in the electric supply service panel with a continuous
copper wire equivalent in size to the circuit conductors supplying this equipment.
16. At least two lugs marked “Bonding Lugs” are provided on the external surface or
on the inside of the supply terminal box or compartment. To reduce the risk of electric
shock, connect the local common bonding grid in the area of the spa to these terminals
with an insulated or bare copper conductor not smaller than No. 6 AWG.
17. All field-installed metal components such as rails, ladders, drains, or other similar
hardware within 3m of the spa shall be bonded to the equipment grounding bus
with copper conductors not smaller than No. 6 AWG.
SAVE THESE INSTRUCTIONS.