INSTALLATION INSTRUCTIONS
LP Gas
If your grill is for
LP gas,
the regulator supplied is set for 11 in. water column (WC) and is for
use with LP gas only. The factory-supplied regulator and hose must be used with a 20 lb. LP
gas tank.
Convert to Natural Gas
Your grill is natural gas convertible. NG kit sold separately (Item #0050772).
Please refer to
page 37
to convert your grill to natural gas.
After the grill is converted to natural gas, the working pressure for natural gas is 7 in. water
column (WC). Gas pressure is affected by gas line size and the length of gas line run from
house. Follow the recommendations in the chart below.
3/4 in. DIA
More than 101 ft.
2/3 in. of run 3/4 in.
1/3 in. of run 1/2 in.
51-100 ft.
1/2 in. DIA
26-50 ft.
3/8 in. DIA
Up to 25 ft.
Tubing Size
Distance
From House to Grill
LP GAS System
Contact your gas supplier for a special regulator for bulk gas that fuels other
appliances
Gas Consumption
19
13,500 x 1
Side Burner
12,000 x 4
Main Burners
BTU/HR
Burner Type
Total gas consumption of this grill with the burner(s) on “HIGH”:
Locating the Grill
This gas appliance is designed and certified for outdoor use only. Do not operate the grill
inside a building, garage, recreation vehicle, screened porch or any enclosed area. Keep the
grill away from windy areas but keep the grill in a well-ventilated area. Do not obstruct the
flow of combustion and ventilation air around the grill.
▲
Warning: Do not place the grill under overhead, unprotected combustible surfaces.
Clearance to Combustible Construction
A minimum clearance of 24 in. from the sides of the grill and a minimum clearance of 48 in.
from the back of the grill to adjacent vertical combustible constructions must be maintained.
!
Reminder: The default hose size is 1/2 in. in DIA, 10 ft. long. Refer to the form below.
!