34
GAS HOOK-UP
6
Open the cylinder valve fully (counterclockwise).
Use a soapy water solution to check all connections
for leaks before attempting to light the grill. See
below. If a leak is found, turn the cylinder valve off
and do not use the grill until a local LP gas dealer
can make repairs.
To disconnect LP gas cylinder:
1.
Turn the burner valves off.
2.
Turn the cylinder valve off fully (turn clockwise to
stop). Detach the regulator assembly from the
cylinder valve by turning the quick coupling nut
counterclockwise.
A cylinder of approximately 12 inches in diameter by
18-1/2 inches high is the maximum size LP gas cylinder
to use.
You must use an OPD gas cylinder which offers an
Overfill Prevention Device.
This safety feature prevents the cylinder from being
overfilled which can cause malfunction of the LP gas
cylinder, regulator and/or grill. In Canada, the LP gas
cylinder must meet the National Standard of Canada,
Can CSA –B339, Cylinders, spheres and Tubes for
Transportation of Dangerous Goods and Commission.
1. The LP gas cylinder must have a shutoff valve,
terminating in an LP gas supply cylinder valve outlet
that is compatible with a Type 1 cylinder connection
device. The LP gas cylinder must also have a safety
relief device that has a direct connection with the
vapor space of the cylinder.
2. The cylinder supply system must be arranged for
vapor withdraws.
3. The LP gas cylinder used must have a collar to protect
the cylinder valve.
PROPER PLACEMENT AND CLEARANCE OF GRILL
Never
use your gas grill in a garage, porch, shed,
breezeway or any other enclosed area. Your gas grill is
to be used
outdoors only,
at least 3 feet from the back
and 2 feet from side of any combustible surface. Your
gas grill should not be used under overhead combustible
construction. Do not obstruct the flow of ventilation air
around the gas grill housing. This outdoor gas grill is not
intended to be installed in or on recreational vehicles
and/or boats.
Never
connect an unregulated LP gas cylinder to your
gas grill. The gas regulator assembly supplied with
your gas grill is adjusted to have an outlet pressure of
11” water column (W.C.)2.74KPA for connection to an
LP gas cylinder.
Replacement regulators and hose assemblies must be
those specified in this manual.
Have your LP gas cylinder filled by a reputable
propane gas dealer and visually inspected and
re-qualified at each filling.
a ) Do not store a spare LP gas cylinder under or near
this appliance.
b) Never fill the cylinder beyond 80 percent full.
c) If the information in a) and b) is not followed
exactly a fire causing death or serious injury may
occur.
Always keep LP gas cylinders in an upright position.
Do not store (or) or use gasoline or other flammable
vapors and liquids in the vicinity of this gas grill.
Do not subject the LP gas cylinder to excessive heat.
Never store an LP gas cylinder indoors. If you store
your gas grill in the garage or other indoor location,
always disconnect the LP gas cylinder first and store it
safely outside.
Place dust cap on cylinder valve outlet whenever the
cylinder is not in use. Only install the type of dust cap
on the cylinder valve outlet that is provided with the
cylinder valve. Other types of caps or plugs may result
in leakage of propane.
LP gas cylinders must be stored outdoors out of reach
of children.
Disconnected LP gas cylinder must not be stored in a
building, garage or any other enclosed area.