background image

 

8

CAM FASTENERS

 

 

 
NOTE:   When facing the interior of the wall panel, all vertical latch access holes should be on the left 
side of the panels. 
 

Before attempting to erect the walk-in, you should know how Master-Bilt cam-lock on some panels, it may be 
difficult to position the hex wrench as showing 

Figure #3, #4, 

and

 #5

.  However, the locking procedure for all 

cam-locks will be as shown. 

Cam 
Wrench

Hook in Open 
Position

  

                Figure #3 
 
NOTE:  All cam-lock locking arms must be in the “open” position before attempting to lack panels 
together. 

 
Push panels together and turn cam-wretch ¼” turn clockwise. This will engage locking arm over locking pin.  
Continue to turn cam-wretch for ½” turn or until panels are fastened together securely. 
 

 

  

                    Figure # 4 
 
CAUTION:  Do not over-tighten cam fasteners. When the cam fastener tool stops, due to normal 
tightening, the fastener has done as much as it can. The panel will be tight and secure to the adjoining 
panel. 
 
 
 

Summary of Contents for CL-156

Page 1: ...Installation Operations Manual Master Bilt Products 908 Highway 15 North New Albany MS 38652 Phone 800 684 8988 PN 090 90000 Rev 05 20 03 LocN...

Page 2: ...2...

Page 3: ...ns 6 Notice to store owners managers 6 Electrical 7 Panel Storage 7 Cam Fasteners 8 Level Floor 9 Caulking 9 Floor Assembly 10 Celing and Wall Penal Assembly 10 Door and Frame installation 10 Refriger...

Page 4: ...ys of sun or near a direct source of radiant heat or airflow This will adversely affect the case and will result in poor performance NOTICE Read this manual before installing your cabinet Keep the man...

Page 5: ...ing signal words are used in the warnings and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUT...

Page 6: ...the equipment clean and sanitary so it will meet your local sanitation codes 3 Rotate your stock so that older stock does not accumulate A First In First Out rotation practice will keep the products...

Page 7: ...spacer Groove edge of panel down 2 X 4 wood frame Figure 2 Whenever possible panels should be stored indoors panels stored indoors may be stored in their original factory crates If it is necessary to...

Page 8: ...will be as shown Cam Wrench Hook in Open Position Figure 3 NOTE All cam lock locking arms must be in the open position before attempting to lack panels together Push panels together and turn cam wret...

Page 9: ...er in both length and width so as to property support the floor panels when the walk in is assembled and the product load is in place Shimming just the outer edges of just the corners of the floor pan...

Page 10: ...should be completely aligned and cam fasteners completely tightened If wall panels appear to have a stair step effect on the top horizontal egde as thy are being assembled the foor is not level At thi...

Page 11: ...drain pan of evaporator coil seal around drain line with silicone or butyl caulking to prevent moist air entering box from outside Start compressor and allow running at least 24 hours before committin...

Page 12: ...ply to door frame TEMPERATURE CONTROLS On the CM models the Temperature Control is on the end penel of the blower housing These controls have an off position at full counter clockwise position and sho...

Page 13: ...oting Guide 1 High head pressure and high back pressure A Condenser coil clogged or restricted B Condenser fan motor defective 2 Low back pressure and low head pressure A Restriction in system B Refri...

Page 14: ...E 070UU 1 SK 3 3A R35XZ070UU 1 SK 1 C12X 070UU 4 SK 1 W46X 070UU 3 28X63 RH NSF 1092 DGT SK 2 2P D28RX070UU 1 F35E 07 UU 1 F35S 070UU 1 TOTALS 12 Vapor Proof Light Globe for door panel 23 00594 1 1 Di...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Reviews: