Discharge over current protection 1 

110±5A, delay 4~6min

Over current

Discharge over current protection 2

300±20A, delay 5~6s 

Over current release method

8s after cutoff the load

Battery 
temperature

Charge over temperature 

Protection @55±5°C

Discharge over temperature

Release @55±5°C

Protection @65±5°C

Release @45±5°C

Short

Do not short-circuit the electrodes

5s after cutoff the load

Over-discharge protection for each cell

2.80±0.04V

Over discharge

Over-discharge release for each cell

3.00±0.04V

Over-discharge release method

Charging recovery

5. Protective Circuit Specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized 
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, 
short circuit. Overall, the BMS helps to ensure safe and accurate running.

Items

Over-charge protection for each cell

Specification

Content

3.75±0.03V

Over charge

Over-charge release for each cell

3.60±0.05V

Over-charge release method

Under the release voltage

Static power

≤200uA

UE-36Li100BL

Summary of Contents for UPOWER Ecoline UE-36Li100BL

Page 1: ...12 1 Remarks 0 33C Issued Date 2018 02 07 Issued Version V00 Multi application LiFePO4 Power UE 36Li100BL 1 General Information This specification defines the performance of rechargeable LiFePO4 batt...

Page 2: ...ion as storage proposal It need at least one charge discharge cycle every six months 3 Test Conditions 3 1 Standard Test Conditions 3 1 1 Unless otherwise specified all performance tests is required c...

Page 3: ...lowing CC 1C CV 43 8V mode to full capacity and then rest it for 1h Repeat above process until full charged capacity is no more than 80 of normal value Accumulated times is defined as cycle life 4 Cyc...

Page 4: ...after cutoff the load Over discharge protection for each cell 2 80 0 04V Over discharge Over discharge release for each cell 3 00 0 04V Over discharge release method Charging recovery 5 Protective Ci...

Page 5: ...of cell proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery Battery should be stayed in the warehouse 15 C 35 C where it s dry clean shade and well...

Page 6: ...ed or suggested charger for this battery If battery emit peculiar smell heating distortion or appear any abnormity during working or storage please stop using and take it out from device If the batter...

Page 7: ...for a long period of time without being used In addition if the various usage conditions such as charge discharge ambient temperature etc are not maintained within the specified ranges the life expec...

Reviews: