background image

www.masterbattery.es

02

Polígono industrial La Dehesa
C/ Dehesa Vieja,nº2 Nave 16
28052 Madrid (Spain)
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

NO.

Items

Description 

Length: 520±3mm

Width:   268±3mm

Height:  222±3mm

Dimension

Self-discharge rate

Operating Temperature 

Approx: 37.3±0.5Kg

Charging

0~45°C

Residual capacity

≤5%/month; ≤50%/years

14

15

16

Weight

Discharging

-20~60°C

Recommended operating temperature

15°C~35°C

Storage Temperature & Humidity Range

Less than 1 month

-20°C~45°C

45% RH~75

% 

RH 

17

Less than 3 months

-10°C~35°C

45% RH~75

% 

RH 

Recommended storage environment

:

15°C~35°C

45% RH~75

% 

RH

13

Long time storage: 
If the battery need be stored for a long time, the voltage should be 39.6V (50% SOC), and stored in the 
condition as storage proposal. It need at least one charge & discharge cycle every six months

3. Test Conditions

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,                   
         Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.

3.2 Standard Charge Mode

"Standard Charge" means at 25±2°C charge to limit voltage with 1C constant current, then charge with 
constant voltage until current less than 0.02C. 

3.3 Quick Charge Mode

"Quick Charge" means at 25±2°C charge to limit voltage with 1C constant current, then charge with constant 
voltage until current less than 0.02C. 

3.4 Standard Discharge Mode

"Standard Discharge" means at 25±2°C discharge to the cut-off voltage with 1.25C current.

3.5 Quick Discharge Mode

"Quick Discharge" means discharge to the cut-off voltage with 1.25C current.

UE-36Li100BL

Summary of Contents for UPOWER Ecoline UE-36Li100BL

Page 1: ...12 1 Remarks 0 33C Issued Date 2018 02 07 Issued Version V00 Multi application LiFePO4 Power UE 36Li100BL 1 General Information This specification defines the performance of rechargeable LiFePO4 batt...

Page 2: ...ion as storage proposal It need at least one charge discharge cycle every six months 3 Test Conditions 3 1 Standard Test Conditions 3 1 1 Unless otherwise specified all performance tests is required c...

Page 3: ...lowing CC 1C CV 43 8V mode to full capacity and then rest it for 1h Repeat above process until full charged capacity is no more than 80 of normal value Accumulated times is defined as cycle life 4 Cyc...

Page 4: ...after cutoff the load Over discharge protection for each cell 2 80 0 04V Over discharge Over discharge release for each cell 3 00 0 04V Over discharge release method Charging recovery 5 Protective Ci...

Page 5: ...of cell proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery Battery should be stayed in the warehouse 15 C 35 C where it s dry clean shade and well...

Page 6: ...ed or suggested charger for this battery If battery emit peculiar smell heating distortion or appear any abnormity during working or storage please stop using and take it out from device If the batter...

Page 7: ...for a long period of time without being used In addition if the various usage conditions such as charge discharge ambient temperature etc are not maintained within the specified ranges the life expec...