www.masterbattery.es
03
NO.
Items
-20°C
Testing method
Internal resistance
3
≤25mΩ
50% battery SOC state frequency of 1 KHZ ac
resistance tester.
Criterion
Discharge
Temperature
Characteristics
At 25±5°C discharge the battery with the current of
0.33C to the cut-off voltage and record charge
capacity. Store the battery at various temperatures
for 2h and discharge the battery with 0.33C to the
cut-off voltage.
0°C
25°C
55°C
≥70%
≥80%
≥100%
≥95%
Charge the battery to full capacity and store it for 28
days, and then discharge it with 0.33C to the cut-off
voltage.
Charge Retention
ability
Residual
capacity ≥80%
Discharge with the current of 0.33C until it can’t
discharge, and then rest it for 1h. Charge the battery
following CC (1C)/CV (43.8V) mode to full capacity,
and then rest it for 1h. Repeat above process until full
charged capacity is no more than 80% of normal
value. Accumulated times is defined as cycle life.
4
Cycle life (DOD%100)
≥2500 cycles
5
Polígono industrial La Dehesa
C/ Dehesa Vieja,nº2 Nave 16
28052 Madrid (Spain)
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]
4. Product Performance
6
Recovery
capacity ≥90%
Rest for 1 hour after fully charged, then discharge with
0.33C current until the battery reaches the discharge
cutoff voltage. Repeat above process for three times,
if the discharge time is not less than 180 minutes, you
can stop and define the Discharging current*time
value (Ah) as battery capacity.
Rated Capacity
1
100Ah
Minimum Capacity
2
98Ah
Though
,
user can read the battery system information
such as voltage, current, SOC, temperature…
and so on.
Communication
Function
Bluetooth
7
UE-36Li100BL