3. Electrical Characteristics & Test Condition
@Ambient Temperature: 25±5ºC & Huminity: 45%~75%.
UE-12Li25
NO.
Items
Nominal Capacity
2
3
4
-20°C
Condition
Internal Impedance
1
≤40mΩ
Test the internal resistance of 50% SOC battery pack
with 1 kHz AC internal resistance test instrument.
Criterion
Rest for 1 hour after fully charged, then discharge
with 0.33C current until the battery reaches the
discharge cutoff voltage. Repeat above process for
three times, if the discharge time is not less than 180
minutes, you can stop and define the Discharging
current*time value (Ah) as battery capacity.
≥24.5Ah
Discharge
Temperature
Characteristics
At 25±5°C discharge the battery with the current of
0.33C to the cut-off voltage and record charge
capacity. Store the battery at various temperatures
for 2h and discharge the battery with 0.33C to the
cut-off voltage.
0°C
25°C
55°C
70%
80%
100%
95%
Charge the battery to full capacity and store it for 28
days, and then discharge it with 0.33C to the cut-off
voltage.
Charge Retention
ability
Remain capacity
≥90%
Short circuit protection
Yes
With short circuit protection, disconnect after charging
recovery.
Charging with this current for more than 0.5h and the
added temperature of battery pack less than 20°C.
MAX charge Current
25A
5
Discharging with this current for more than 0.5h and
the added temperature of battery pack less than
35°C.
MAX discharge Current
25A
Discharge with the current of 0.5C until it can’t
discharge, and then rest it for 1h. Charge the battery
following CC (0.33C)/CV (14.6V) mode to full capacity,
and then rest it for 1h. Repeat above process until full
charged capacity is no more than 80% of normal
value. Accumulated times is defined as cycle life.
6
Cycle life (DOD%100)
≥1875 cycles
7
8
Polígono industrial La Dehesa
C/ Dehesa Vieja,nº2 Nave 16
28052 Madrid (Spain)
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]
www.masterbattery.es
03