11
Recommended Panel Configuration
Specifications
Solar panel
Nominal Max. Power (Pmax) (W)
430
455
520
535
Opt. Operating Voltage (Vmp) (V)
40.3
41.3
41.6
41.9
Opt. Operating Current (Imp) (A)
10.68
11.02
12.5
12.77
Open Circuit Voltage (Voc) (V)
48.3
49.3
49.14
49.44
Short Circuit Current (Isc) (A)
11.37
11.66
13.23
13.5
For 7.5KW input recommendation
Numbers in series of MPPT1
12
11
11
10
Numbers of strings in MPPT1
1
1
1
1
Maximum input voltage of MPPT1 (V)
579.6
542.3
540.54
494.4
Input power of MPPT1 (W)
5160
5005
5720
5350
Numbers in series of MPPT2
6
6
4
5
Numbers of strings in MPPT2
1
1
1
1
Maximum input voltage of MPPT1 (V)
289.8
295.8
196.56
247.2
Input power of MPPT2 (W)
2580
2730
2080
2675
Total input power (W)
7740
7735
7800
8025
Minimum input recommendation
Numbers in series of MPPT1
5
5
5
5
Numbers of strings in MPPT1
1
1
1
1
Maximum input voltage of MPPT1 (V)
241.5
246.5
245.7
247.2
Input power of MPPT1 (W)
2150
2275
2600
2675
Numbers in series of MPPT2
5
5
5
5
Numbers of strings in MPPT2
1
1
1
1
Maximum input voltage of MPPT1 (V)
241.5
246.5
245.7
247.2
Input power of MPPT2 (W)
2150
2275
2600
2675
Total input power (W)
4300
4550
5200
5350