Amate Electroacústica,s.l.
MA206/MAW115.Version 1.3
Nov 08
9
2.5.1.Rear connections
Each unit of
MA-206/D
includes a Rear Panel with the following items:
A)
RJ45 INPUT
: PC Signal Input
B)
RJ45 LINK
: PC Link Signal
C)
INPUT SIGNAL
: Balanced XLR input signal connector
1= Shield 2= Live 3= Return
D)
LINK INPUT SIGNAL
: Balanced XLR connector for paralleling several units, which
will share the same input.
1= Shield
2= Live 3= Return
E)
AC INPUT
: Input PowerCon connector.
F)
AC STACKING OUTPUT
: PowerCon Output connector to feed a secondary
cabinet.
G)
AC MAINS LED INDICATORS
ON:
Lights when AC input is correct.
STAND BY:
Lights during power-up sequence.
OVERVOLTAGE PROTECTION:
Lights if AC input voltage is over 250VAC. The
system protects itself and will not start up until AC level is correct.
H)
SIGNAL OUT
: Signal output to feed 3 passive units of
MA-206/P.
Fig.9.
Connections panel for
MA-206/D
2.6. MA-206/P
P=Passive version of
MA-206
feed by a
MA206/D.
Transducers and waveguides are
those explained in 2.2 and 2.3.
2.6.1. Rear connections
Each unit of
MA-206/P
includes a Rear Panel with the following items: