Caution 

  To avoid damage to the Meter or to the equipment under test, 

disconnect power and discharge all high-voltage capacitors 
before measurement capacitance. 

  5-4 Diode Check 

You can selecting the Scanning Mode or the Diode Mode by 

The ‘FUNC’ push button. 

 

Use the diode test mode to check diodes, transistors and other 

semiconductor device. In the diode test mode sends

 

a current through 

the

 

semiconductor junction, and the measure the voltage drop across 

the junction. A good silicon junction drop between 0.5V 

  0.8V. 

 

For forward voltage drop reading on any semiconductor component, 

the test pin(connected to the ‘INPUT’ terminal) is    in touch with the 

component anode and    the another test pin is in touch with on the 

component cathode. The measured value show on the LCD. 

 

Reverse the test pin and measure the voltage across the diode again. 

 

If diode is good, the display shows “OL”. 

 

If diode is shorted, the display shows 0 (zero) in both direction. 

 

If display shows “OL” in both direction, the diode is open. 

5-5. Continuity Check 

      May selecting Scanning Mode or Continuity Mode by ’FUNC’ push 

button. 

      When the resistance reading is less than 30

Ω

, the buzzer   

      generates 2KHz beep to indicate continuity. 

 

6. Maintenance 

6-1. Replacing The Battery 

When meter display 

, the battery must be replace to maintain 

normal operation. 

 

Open the battery cover on the bottom case by 

screwdriver. 

 

Remove old battery and snap new one into battery 

holder 

Note: 

Lithium Battery type: 3V    CR2032   

 

6-2. Cleaning 

The meter can be cleaned with soft clean cloth to remove any oil, grease or 

grim.   

Do not use    liquid solvent or detergent.   

 

 
 
 
                                            - END - 
 
 
 
                                     

Summary of Contents for MS8910

Page 1: ...nd Indicators 3 1 Product Illustration 3 2 Push Buttons 3 3 LCD display 4 Specification 4 1 General Feature 4 2 Electrical Specification 5 Testing Operation 5 1 Scanning Mode 5 2 Resistance Measurement 5 3 Capacitance Measurement 5 4 Diode Check 5 5 Continuity Check 6 Maintenance 6 1 Replacing The Battery 6 2 Cleaning ...

Page 2: ... thermo plastic elastomer and the two testing pins has been gold plated so that it is reduce pin contact resistance and prevent to get rusty This operating instruction covers information on safety and caution so please read relevant information carefully and observe all the warming and note strictly 2 Safety Note The following safety notes should be observed prior to using This Tester and any asso...

Page 3: ...rm the Scanning Mode and then the SCAN and sign is displayed on the LCD This is indicate the Tester is inter to the auto scanning mode and will be automatically identify the resistor capacitor diode and continuity measurement mode The FUNC Button is used to selecting some one measurement mode manually 2 HOLD Press HOLD Button to enter or exit the hold mode In any measurement mode This key is act w...

Page 4: ...ion by one FUNC Push Button Data Hold function Continuity Checking function Over Load Indication OL Low Battery Indication Power Supply 3V Lithium Battery CR2032 1pc Test Pins is Gold Plated Auto Power OFF If the Tester is idle for more than 10 minutes The Tester automatically turns the power off Operating temperature Humidity 0 40 32 104 80 RH Storage temperature Humidity 10 50 14 122 70 RH Safet...

Page 5: ...canning mode and automatically identified the resistor capacitor diode and continuity and then enter to the corresponding measurement mode In the Scanning Mode when two pins are in touch with the object being measured the measured value will be displayed on the LCD Caution When measuring SMD device on the PCB You must be Disconnect power and discharge all high voltage Capacitors 5 2 Resistance Mea...

Page 6: ...n touch with on the component cathode The measured value show on the LCD Reverse the test pin and measure the voltage across the diode again If diode is good the display shows OL If diode is shorted the display shows 0 zero in both direction If display shows OL in both direction the diode is open 5 5 Continuity Check May selecting Scanning Mode or Continuity Mode by FUNC push button When the resis...

Reviews: