already set it up properly.
3) Turn the voltage knobs down (knob 12 & 13).
4) With no load connected, turn the power supply on. The power supply is reset and ready to be used.
4-3 Recovery from Over-temperature Protection
If the internal temperature is too high, the power supply is disabled due to over-heating, and the OT indicator turns red.
When this happens, disconnect the load; correct the cause of the over-heating, and the power supply will recover
automatically. Typical cause of over-heating includes:
1) Not enough ventilation due to space limit.
2) Ambient temperature is too high.
3) The cooling fan stops working.
4) Output exceeds the rated range.
Caution:
the power supply can be operated at the maximum outputs (both current and voltage) for less than 15
minutes. For continuous operation, either the voltage or the current should be below 80% of the maximum rated value.