Contact Inputs
•
The two contact inputs are not activated yet. E.g. a shuttle service
will be utilized in the near future.
Analog Operation
•
The operation in analog mode may be prohibited by setting CV29 – Bit2 accordingly.
•
The eMOTION XL Decoder is programmed with an internal motor characteristic curve which
enables a soft start in analog mode by measuring the track voltage. An analog back EMF may
be switched on with CV49-Bit2.
•
All three light outputs are on in analog operation regardless of the driving direction.
All six function outputs may be activated. Features like dimming and blinking are available in
analog operation. The pulse generator (F6) cannot be used in analog.
Reset Mode + Software (Firmware) Update
•
CV7 provides a feature to reset the basic functions (Value 55), motor data (value 66) and Light
and Function Output (Value 77) to the original values. This works only with the function “write
CV”.
•
See attachment 7 for CV assignment.
•
By means of a PC Program the internal software (Firmware) of the eMOTION XL Decoder can
be updated.
Programming of Binary Values
•
Some of the CVs consist of binary values. This means that several values are combined in one
value. Each function has a position and a value. A deactivated function generally has the value
“0”, an active function the respective value according to the list. For programming all values of
the functions have to be summed up and then stored as the final CV value.
37