![Masport RANGITATA ULEB Installation & Operation Manual Download Page 15](http://html.mh-extra.com/html/masport/rangitata-uleb/rangitata-uleb_installation-and-operation-manual_1735359015.webp)
15
4.0 Rangitata ULEB (Zero Clearance) - Technical Specifications
Rangitata fire has been tested and complies to following standards & tests:
Environment Canterbury's Real-life test
- Canterbury test method CM1
NZ National Environmental Test Standards
- AS/NZS 4012:2014 & AS/NZS 4013:2014.
NZ National Environmental Safety Test Standard
- AS/NZS 2918:2001, Appendix B
Built-In Fascia Dimensions
870 mm Wide x 77 mm Deep x 782 mm High
Firebox with ZC Dimensions
770 mm Wide x 607 mm Deep x 680 mm High
Net Weight of Burner
140.0 kg
Test Method
Emissions
mg/MJ
Emissions
g/kg
Efficiency
%
Authorization
Nos
Real-Life Test
Canterbury Method V1.6
38 mg/MJ
-
-
CRC 203666
National Environment Standard
AS/NZS 4012/13:2015
-
0.41 g/kg
68%
CRC 203667
Heating Capacity
Small to Medium Homes
Schematic and Overall Dimensions
`
Fig. 10 - Rangitata Built-In ZC Overall Dimensions
Summary of Contents for RANGITATA ULEB
Page 21: ...21 Fig 14 Contents of the Rangitata Zero Clearance Box Pack ...
Page 34: ...34 ...