Masport Inbuilt Gas Fireplace
- 6 -
MATERIALS REQUIRED
No mains voltage electric power supply is required for the gas control to operate. A 240 Volt AC power cord is hooked
up to the fan switch and blower. Plug 3-wire cord into a suitable receptacle. Do not cut the ground terminal off under any
circumstances.
When connected with 240 volts, the appliance must be electrically grounded in accordance with local codes.
INSTALLATION SEQUENCE
The Masport Gas Insert is installed in the steps as listed below. Detailed instructions follow.
1) Check the clearances to ensure that the fire will fit the fireplace recess and clearances to combustibles will be
maintained. See page 7.
2) Prepare the fireplace recess. See page 7.
3) Install the flue or flexi-liner in accordance with AG 601 or NZS 5261, refer to instructions provided with the flue kit.
4) Install the gasfire into the fireplace recess and connect to the flue system. See page 8.
5) Make the gas connections and electrical connection for fan. See page 8.
6) Assemble and install the fascia and fan switch etc. See pages 9 & 10.
7) Remove the glass/window and install the embers etc. See page 10 &11.
8) Re-install the glass front (Flush or Bay). See pages 10 & 11.
9) Install louvres (Flush or Bay).
10) Final check: Before leaving this unit with the customer, the installer must ensure that the appliance is firing
correctly. This includes:
a) Checking the manifold pressure. See page 11.
b) Clocking the appliance to ensure the correct firing rate.
c) Adjusting the primary air, if required, to ensure that the flame does not carbon on the components.
d) Ensuring that the flue is drawing correctly.
(Copy of Lighting Instruction plate)