Masport Fatso Installing And Operating Instructions Download Page 7

FLUE INSTALLATION

The stove must be installed using a Masport approved flue kit (including a ceiling plate).
Approved flue kits are supplied with detailed fitting instructions which, if followed, will
ensure that the  installation  will meet the required  safety standards for  performance  and
durability.

FIREPLACE INSTALLATION

The  model  most convenient  for this type of  installation  is  the  YUKON  as  it  has  a  rear
flue  outlet  enabling  the  flue  to  be  routed  up  the  chimney.  A  straight  flue  socket  will
usually  be  needed  to  replace  the  standard  elbow  normally  fitted  to  the  YUKON.  The
baffle inside the firebox must be refitted as usual. When the straight socket is fitted, the
damper is fully open when its handle is in line with the flue, not when it is vertical as is
the case for the standard elbow.

A fireplace installation must meet the following requirements:-

• The fireplace and chimney must be thoroughly cleaned and checked for soundness.

• The chimney must not connect to a second fireplace.

•  The  joint  between  the  chimney  face  and  the  fireplace  surround  must  be  checked  and
sealed to prevent leakage if necessary.

• Where the fireplace is in a heat sensitive wall it must have a non-metallic heat resistant
surround extending at least 600mm each side of the  recess centreline and  up to  at least
1400mm above the base of the fireplace recess.

•  All  safety  clearances  between  the  stove  and  any  nearby  heat-sensitive  material
(including material above the stove), must be strictly maintained.

• A  flue  pipe  must  be  fitted  right  up  the  chimney,  and  the  space  between  the  flue  pipe
and  chimney  must be ventilated at the  top.  The  area  of  this  vent  must  be  not  less  than
13,000mm

2

. The vent must be fitted with  means  to  prevent significant ingress  of water

and debris.

•  We  recommend  fitting  a  horizontal  register  plate  at  the  lower  end  of  the  chimney  to
minimise room heat loss. The  register  plate  should provide the  same  area  of  ventilation
as at the top of the chimney.

•  Provision  must  be  made  to  support  the  weight  of  the  flue  and  to  permit  the  free
expansion of the flue pipe when it heats up.

• The flue must be secured to the flue collar to prevent accidental separation.

•  The  hearth  (floor  protector)  must  extend  at  least  325mm  beyond  the  feet  in  all
directions. If the hearth has to be  extended  to attain this dimension, the  extension  must
be as per one of our recommended constructions, and it must be fixed and sealed to the
existing hearth to prevent any possibility of a cinder falling through the joint to the floor
below.

MANTEL-SHELF SHIELDING

When the heater is installed in front of a fireplace, any heat sensitive material (such as a
mantel-piece)  which  protrudes  from  the  face  of  the  fireplace  surround  will  need  to  be
completely  shielded.  This  shielding  is  best  provided  by  a  sheet  metal  panel  fastened
12mm  from  the  face  to  be  protected  on  heat  resistant  spacers.  The  inner  edge  of  the
shield  must  abut  the  face  of  the  fireplace  surround  and  the  outer  edge  and  ends  must
have an unobstructed 10mm gap to allow cooling air circulation.

6

Summary of Contents for Fatso

Page 1: ...PITTSBURGH FATSO OREGON KLONDIKE YUKON POT BELLY STOVES INSTALLING AND OPERATING INSTRUCTIONS 585845...

Page 2: ...LING THE FIRE 9 REFUELLING 10 SAFETY 10 MAINTENANCE 10 STOVE DIMENSIONS 11 INTRODUCTION Congratulations on purchasing a Masport pot belly stove If correctly installed and operated according to these i...

Page 3: ...the curved edge down and the word FRONT facing inward Slide the plate around on the ridge in the top chamber until the top edge of the plate engages behind the post hanging down inside the top chambe...

Page 4: ...hether the elbow or straight flue socket is used INSTALLING THE STOVE This section covers all models with or without water heating coils except for the special case of a YUKON installed in a fireplace...

Page 5: ...on slots must be provided at the top and bottom of each shield each slot having a cross sectional area not less than half the width of the shield multiplied by the spacing depth The slots should as fa...

Page 6: ...ting hearth to protect the floor from heat damage If the rearward extension of the hearth is not limited by a wall heat screen it must extend back from the stove feet by 300mm for the PITTSBURGH and F...

Page 7: ...ial including material above the stove must be strictly maintained A flue pipe must be fitted right up the chimney and the space between the flue pipe and chimney must be ventilated at the top The are...

Page 8: ...ater Piping instructions are included with the water heating tube kit Two safety requirements must be stressed WARNING DO NOT ATTEMPT TO LIGHT A STOVE FITTED WITH A WATER HEATING COIL UNLESS THE COIL...

Page 9: ...n instructions LIGHTING THE FIRE CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS Check that the ash door is closed and is sealing properly E...

Page 10: ...ly by rotating the round air supply control plate on the front door Open the vents to increase heat output and close them to reduce heat output Further reduction of the heat output can be had by parti...

Page 11: ...not modify the stove or flue in any way without obtaining written approval from the Manufacturer CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED IF ANY PARTS ARE BROKEN OR MISSING MAINTENANCE Cleaning...

Page 12: ...ight 71kg 44kg 69kg 37kg 48kg Shipping Dimensions W 535mm D 485mm H 805mm Vol 0 21m3 W 480mm D 380mm H 650mm Vol 0 119m3 W 570mm D 515mm H 615mm Vol 0 18m3 W 435mm D 380mm H 500mm Vol 0 083m3 W 475mm...

Reviews: