Masport Fatso Installing And Operating Instructions Download Page 12

STOVE DIMENSIONS

Pittsburgh

Klondike

Fatso

Yukon

Oregon

Front

View

Side

View

850

510

545

580

650

380

420

460

675

510

560

545

580

545

380

420

490

380

580

420

500

470

Belly

Ring  Dia.

445mm

365mm

365mm

Flue I.Dia.

114mm

114mm

114mm

114mm

114mm

Shipping

Weight

71kg

44kg

69kg

37kg

48kg

Shipping

Dimensions

W 535mm

D 485mm
H 805mm

Vol. 0.21m

3

W 480mm

D 380mm
H 650mm

Vol. 0.119m

3

W 570mm

D 515mm
H 615mm

Vol. 0.18m

3

W 435mm

D 380mm
H 500mm

Vol. 0.083m

3

W 475mm

D 475mm
H 540mm

Vol. 0.122m

3

SUPPLIED BY:-.........................................................................

......................................................................

INSTALLED BY:-.......................................................................

......................................................................

HEAD OFFICE - NEW ZEALAND

HEAD OFFICE - AUSTRALIA

1-37 Mt Wellington Highway

P.O. Box 533, Braeside

Panmure, Auckland 6

Postcode: 3195

Phone: (9) 571 1200

Phone:  1300 366 225

Fax:  (9) 571 5864

Fax:  1800 035 594

11

Summary of Contents for Fatso

Page 1: ...PITTSBURGH FATSO OREGON KLONDIKE YUKON POT BELLY STOVES INSTALLING AND OPERATING INSTRUCTIONS 585845...

Page 2: ...LING THE FIRE 9 REFUELLING 10 SAFETY 10 MAINTENANCE 10 STOVE DIMENSIONS 11 INTRODUCTION Congratulations on purchasing a Masport pot belly stove If correctly installed and operated according to these i...

Page 3: ...the curved edge down and the word FRONT facing inward Slide the plate around on the ridge in the top chamber until the top edge of the plate engages behind the post hanging down inside the top chambe...

Page 4: ...hether the elbow or straight flue socket is used INSTALLING THE STOVE This section covers all models with or without water heating coils except for the special case of a YUKON installed in a fireplace...

Page 5: ...on slots must be provided at the top and bottom of each shield each slot having a cross sectional area not less than half the width of the shield multiplied by the spacing depth The slots should as fa...

Page 6: ...ting hearth to protect the floor from heat damage If the rearward extension of the hearth is not limited by a wall heat screen it must extend back from the stove feet by 300mm for the PITTSBURGH and F...

Page 7: ...ial including material above the stove must be strictly maintained A flue pipe must be fitted right up the chimney and the space between the flue pipe and chimney must be ventilated at the top The are...

Page 8: ...ater Piping instructions are included with the water heating tube kit Two safety requirements must be stressed WARNING DO NOT ATTEMPT TO LIGHT A STOVE FITTED WITH A WATER HEATING COIL UNLESS THE COIL...

Page 9: ...n instructions LIGHTING THE FIRE CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS Check that the ash door is closed and is sealing properly E...

Page 10: ...ly by rotating the round air supply control plate on the front door Open the vents to increase heat output and close them to reduce heat output Further reduction of the heat output can be had by parti...

Page 11: ...not modify the stove or flue in any way without obtaining written approval from the Manufacturer CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED IF ANY PARTS ARE BROKEN OR MISSING MAINTENANCE Cleaning...

Page 12: ...ight 71kg 44kg 69kg 37kg 48kg Shipping Dimensions W 535mm D 485mm H 805mm Vol 0 21m3 W 480mm D 380mm H 650mm Vol 0 119m3 W 570mm D 515mm H 615mm Vol 0 18m3 W 435mm D 380mm H 500mm Vol 0 083m3 W 475mm...

Reviews: