FR27 Masport Rear Flued Room Sealed Freestanding Gas Heater
8
INSTALLATION
PLANNING YOUR FLUEING INSTALLATION
RESIDENTIAL INSTALLATIONS
You will require the following components with your new Masport Rear Flued Room Sealed Freestanding Gas Stove. Please
review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer.
Decorative brass or chrome trim kits are available from Simpson Dura-Vent for their wall thimbles, as well as a square wall
thimble cover.
Note:
These are the minimum pieces required. Other parts may be required for your particular installation.
Minimum components for a Horizontal Installation:
640-944
Horizontal Termination Kit which includes:
1
946-201
6-5/8"(168mm) Dia. x 18"(457mm) Black Pipe
1
946-207
4"(102mm) Dia. x 18"(457mm) Aluminum Flue
1
640-530
Riser Vent Terminal
1
946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1
640-545
Decorative Wall Trim (Black)
1
948-128
Tube Mill-Pac
Screws
Optional Components:
946-204
45
o
Elbow - 6-5/8"(168mm) Black pipe and 4"(102mm) Aluminum Flue
946-205
Vinyl Siding Shield for Riser Vent Terminal
946-208/P
Flue Guard
940
Square Wall Thimble Cover*
981
Snorkel Termination (36"(914mm))*
982
Snorkel Termination (14"(356mm))*
942
Wall Penetration
Heat Shield*
* Simpson Dura-Vent
components
See page 9 for Exterior Flue Termination requirements. The
FR27 is only approved for a horizontal termination. See the
diagram for minimum and maximum pipe lengths.
When planning your installation, it will be necessary to select the
proper length of flue pipe for your particular requirements. Deter-
mine the minimum clearance to combustibles from the rear of the
unit to the wall. It is also important to note the wall thickness.
Before cutting the flue hole through the wall ensure that ALL flue
and termination clearances (see page 9) will be met.
The flueing arrangements shown on the diagram, have a minimum
of 75% (flue loss) efficiency with Fan Off, as required for manufac-
tured homes. (Actual efficiency may be as high as 85%.)
*If this is an outside corner, the minimum distance
between the flue and the outside corner is 12" (30cm).
See "F" on the diagram on page 9.
Alternate Snorkel
Termination Cap
Part #982 (14")
Part #981 (36")