Masport F27-LP Owners & Installation Manual Download Page 4

FR27 Masport Rear Flued Room Sealed Freestanding Gas Heater

4

This is a copy of the label that accompanies each  Rear Flued

Room Sealed Freestanding Gas Stove. We have printed a

copy of the contents here for your review. The safety label is

located on the inside of the drop down pedestal door.

SAFETY LABEL

NOTE: Masport units are constantly being improved. Check

the label on the unit and if there is a difference, the label on the

unit is the correct one.

Copy of Safety Label for FR27

DOOR SEAL ADJUSTMENT:

Please check that door is properly sealed.

Periodic adjustment of latch may be required.

MADE IN CANADA / FABRIQUE AU CANADA

Fireplace Products International Ltd., Delta, BC, Canada

A 7-1/2" /190 mm

B 3"

/ 7 6 mm

E 4-1/2" / 114 mm

Min. Ceiling Height

from top of unit / Min.

Plafond  Hauteur en

haut de l'appareil:

36" / 914 mm

Minimum Clearances

to Combustibles/

Degagement Minimum

Des Materiaux

Combustibles

WH - U

Serial No./No de serie

VENTING: Use listed Simpson Dura-Vent GS System. Only for direct discharge without duct connection. This

appliance must be installed in accordance with the manufacturer's installation instructions and with local codes,

if any; if not, follow the current ANSI Z223.1 in the USA or the current CAN/CGA-B149 in Canada.

For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the

manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR,

Part 3280,  or  the  current  Standard  for  Fire  Safety  Criteria  for  Manufactured  Home  Installations,  Sites,  and

Communities  ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE  ÉTIQUETTE

Model/Modele:

U27-NG2

Listed:  GRAVITY DIRECT VENT WALL FURNACE

Certified for/Certifiée pour: CANADA AND U.S.A.

Tested to: CGA 2-17-M91, CAN1-2.19-M81, ANSI Z21.44-1995,

                   ANSI Z21.88a-1998/CSA 2.33a-M98

REPORT NO. 

476-1537-00 (Feb. 2000)

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

FACTORY EQUIPPED FOR NATURAL GAS: Model U27-NG2

Minimum supply pressure 5.0"

WC/C.E. (1.24Kpa)

Manifold pressure High

3.8"

WC/C.E. (0.947Kpa)

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Orifice size

#40

DMS

Output - Fan ON

21,060 Btu/h

(6.17Kw/h)

Output - Fan OFF

20,655 Btu/h

(6.05Kw/h)

Altitude

0-4500 ft/pi

(0-1370m)

Maximum Input

27,000 Btu/h

(7.91Kw/h)

Minimum Input

13,500 Btu/h

(3.96Kw/h)

ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:

Pression d’alimentation minimum

Pression à la tubulure d’échappement élevée

Pression à la tubulure d’échappement élevée

Dimensions de l’orifice

Débit calorifique-Ventilateur en Marche Btu/h

Débit calorifique-Ventilateur Éteint Btu/h

L’altitude

Débit calorifique maximum selon

Débit calorifique minimum selon
ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

Pression d’alimentation minimum

Pression à la tubulure d’échappement élevée

Pression à la tubulure d’échappement élevée

Dimensions de l’orifice

Débit calorifique-Ventilateur en Marche Btu/h

Débit calorifique-Ventilateur Éteint Btu/h

L’altitude

Débit calorifique maximum selon

Débit calorifique minimum selon

FACTORY EQUIPPED FOR PROPANE: Model U27-LP2

Minimum supply pressure 12"

WC/C.E. (3.00Kpa)

Manifold pressure High

11"

WC/C.E. (2.74Kpa)

Manifold pressure Low

2.9"

WC/C.E. (0.72Kpa)

Orifice size

#53

DMS

Output - Fan ON

21,330 Btu/h

(6.25Kw/h)

Output - Fan OFF

20,871 Btu/h

(6.11Kw/h)

Altitude

0-4500 ft/pi

(0-1370m)

Maximum Input

27,000 Btu/h

(7.91Kw/h)

Minimum Input

13,500 Btu/h

(3.96Kw/h)

908-044  WD

ver. 07/00

Model/Modele:

U27-LP2

Summary of Contents for F27-LP

Page 1: ...n the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFEREN...

Page 2: ...pliances has been designed to provide you with all the warmth and charm of a woodstove at the flick of a switch The models FR27 NG and FR27 LP of this series has been approved by Warnock Hersey for bo...

Page 3: ...6 Warranty Warranty 31 Specifications diagram 2 Safety Label 4 Installation Before You Start 5 General Safety Information 5 Installation Checklist 6 Clearances to Combustibles 6 Locating Your Gas Stov...

Page 4: ...a Electrical supply 115VAC 1 13 A 60 Hz Not for use with solid fuel DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE TIQUETTE Model Modele U27 NG2 Listed GRAVITY DIRECT VENT WALL FURNACE Certified for Ce...

Page 5: ...e must be installed on a flat solid continu ous surface e g wood metal concrete This may be the floor or it can be raised up on a platform to enhance its visual impact The appliance may be installed o...

Page 6: ...lize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer CLEARANCES TO COMBUSTIBLES The clearances listed are MI...

Page 7: ...ystem Common flue systems are prohibited SAFETY PRECAUTIONS FOR THE INSTALLER 1 Wear gloves and safety glasses for protection 2 Exercise extreme caution when using ladders or on roof tops 3 Be aware o...

Page 8: ...45o Elbow 6 5 8 168mm Black pipe and 4 102mm Aluminum Flue 946 205 Vinyl Siding Shield for Riser Vent Terminal 946 208 P Flue Guard 940 Square Wall Thimble Cover 981 Snorkel Termination 36 914mm 982...

Page 9: ...assembly within 3 90cm horizontally from the centerline of the regulator J Clearance to service regulator flue outlet Canada min 72 1 8m USA min 36 90cm K Clearance to non mechanical air supply inlet...

Page 10: ...could cause high temper atures and may present the possibility of a fire b The location of the horizontal vent termination on an exterior wall must meet all local and national building codes and must...

Page 11: ...wall thimble cover over the vent pipe then slide the Wall Penetration Heat Shield Part 946 202 over the vent pipe Dia 3 d Slide the appliance and vent assembly towards the wall carefully inserting th...

Page 12: ...ur local authorities and the CAN CGA B149 installation codes For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use onl...

Page 13: ...ARNING Dangerousoperatingconditionsmayoccuriftheselogsarenotpositionedintheirapprovedlocations Read the instructions below carefully and refer to the diagrams If logs are broken do not use the unit un...

Page 14: ...mpresses after a few fires and after glass replacement Turn the latch catch inward or outward GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its...

Page 15: ...ontrol is now ready for operation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired Note Preferable if the thermostat is installed on an interior wall Masport offers...

Page 16: ...sure that the flame does not carbon First allow the unit to burn for 15 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior f...

Page 17: ...may causecondensationandfogtheglass Thiscondensa tionisnormalandwilldisappearinafewminutesasthe glassheatsup DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE OPERATING INSTRUCTIONS Before op...

Page 18: ...does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your servic...

Page 19: ...ppliance Fan Masport gas appliances use high tech fans to push heated air farther into the room It is not unusual for the fan to make a whirring sound when ON This sound will increase or de crease in...

Page 20: ...h wall paint Masport uses StoveBright Paint Metallic Black 6309 3 Make a periodic check of burner for proper position and condition Visually check the flame of the burner period ically making sure the...

Page 21: ...ENT Your Masport heater is supplied with high temperature 5mm Neoceram silica coated ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your gla...

Page 22: ...quippedwithathreepronged ground ing plug for your protection against shock hazard and should be plugged directly into a properly grounded three prongreceptacle Donotcutorremovetheground ing prong from...

Page 23: ...You may want to put a soft cloth on the base of the unit so that when the pedestal door is open it doesn t scratch the paint See diagram below 2 Undo the six screws holding the control panel in place...

Page 24: ...l panel is off or you can access it through the rear pedestal cover plate 6 Carefully remove the logs embers and rockwool 7 Remove burner See diagram below Note Use a magnetic type screwdriver if poss...

Page 25: ...Note For service technicians only See the Masport Troubleshooting Guide for more detailed information Troubleshooting Masport Gas Products Part 908 439 TROUBLESHOOTING GUIDE Check pilot flame must im...

Page 26: ...d actioned by an approved Masport Service Agent This Express Warranty Does Not Cover 1 Defects malfunctions or failures caused by incorrect installation normal wear and tear misuse neglect accidental...