FR27 Masport Rear Flued Room Sealed Freestanding Gas Heater
6
6)
Inspect the flueing system annually for blockage and any
signs of deterioration.
7)
Flueing terminals shall not be recessed into a wall or
siding.
8)
Any safety glass removed for servicing must be replaced
prior to operating the appliance.
9)
To prevent injury, do not allow anyone who is unfamiliar
with the operation to use the fireplace.
INSTALLATION CHECKLIST
1)
Check Clearances to Combustibles (page 6), location of
unit (page 7) and flueing requirements (pages 7 to 9).
2)
Install flueing: Check all flueing requirements, pages 9 to
10.
3)
Make gas connections, page 12. Test the pilot. Must be as
per diagram, pages 12 and 20.
4)
Install logs and embers and rockwool where indicated on
page 13.
5)
Install Front Door, page 14.
6)
Test Gas Pressure, page 14.
7)
Install optional Wall Switch, Remote Control, or Wall
Thermostat, pages 15 and 16.
8)
Final check, page 16.
Before leaving this unit with the customer, the installer must
ensure that the appliance is firing correctly and operation fully
explained to customer.
This includes:
1)
Clocking the appliance to ensure the correct firing rate
(rate noted on label) after burning appliance for 15
minutes.
2)
If required, adjusting the primary air to ensure that the
flame does not carbon. First allow the unit to burn for 15-
20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting
or carboning that results in damage is not the responsibility of
the manufacturer.
CLEARANCES TO COMBUSTIBLES
The clearances listed are MINIMUM distances. Measure the
clearance to both the appliance and the chimney connector.
The farthest distance is correct if the two clearances do
not coincide. For example, if the appliance is set as indicated
in one of the diagrams but the connector is too close, move the
stove until the correct clearance to the connector is obtained.
This appliance may be installed only with the clearances as
shown in the situations pictured. Do not combine clearances
from one type of installation with another in order to
achieve closer clearances.
This unit can be installed on a solid combustible surface like
a wood floor. This unit can also be installed directly on
carpeting or vinyl when the bottom pedestal cover plate
(provided with unit ) is installed.
Use the minimum clearances shown in the diagrams below:
Minimum ceiling height is 36" /
Minimum ceiling height is 36" /
Minimum ceiling height is 36" /
Minimum ceiling height is 36" /
Minimum ceiling height is 36" /
914 mm from top of unit.
914 mm from top of unit.
914 mm from top of unit.
914 mm from top of unit.
914 mm from top of unit.
INSTALLATION
FR27-NG & FR27-LP Clearances
A Side Wall to Unit
7-1/2" / 190 mm
B Back Wall to Unit
3" / 76 mm
E Side Wall to Unit
4-1/2" / 114 mm
FR27-NG & FR27-LP Reference Dimensions
C Floor to Flue Centerline
23" / 584 mm
D Side Wall to Flue Centerline
20-1/2" / 521 mm