Masport P36-3 Gas Inbuilt
6
INSTALLATION
Clearances for Bay or Flush Front
NOTE: The minimum floor clearance must
be maintained from the top surface of the
carpeting, tile, etc.
Minimum Clearance from Top of Unit to:
Mantel* Minimum
7"
(177mm)
Ceiling from top of unit.
32"
(1016mm)
Side Wall Clearance
Bay or Flush Front
6"
(152mm)
Barcelona Trim
8"
(203mm)
Horizontal Flue Clearances
Top
2"
(51mm)
Side
1-1/2" (38mm)
Bottom
1-1/2" (38mm)
Vertical Flue Clearances 1-1/4" (32mm)
Alcove Clearances**:
Max. Depth
36"
(914mm)
Min. Width
48"
1219mm)
Min. Height
72"
1829mm)
* see mantle clearance instructions
(pages 7 & 8).
CLEARANCES
The clearances listed below are Minimum dis-
tances unless otherwise stated:
A major cause of chimney related fires is
failure to maintain required clearances
(air space) to combustible materials. It is
of the greatest importance that this fire-
place and flue system be installed only in
accordance with these instructions.
Clearance to Combustibles from:
Back
0"
(0mm)
Side
0"
(0mm)
Floor
0"
(0mm)
Diagram 1
LOCATING YOUR
GAS FIRE
1) When selecting a location for your fire,
ensure that the clearances outlined on this
page are met.
2) Provide adequate clearances for servic-
ing.
3) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or
raised up on a platform to enhance its visual
impact. If the appliance is going to be in-
stalled on carpeting, combustible linoleum
tile or other combustible material other than
wood flooring, the appliance must be in-
stalled on a metal or wood panel extending
the full width and depth of the appliance.
4) The P36 Co Axial Flue Gas Fireplace can be
installed in a recessed position or framed
out into the room as in A, B, C, D. See
Diagram 1.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. See page 27.
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
5) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P36 Co Axial Flue Gas Fireplace is
approved for alcove installations, which
meet the clearances listed on this page.
7) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance. Have an
authorized inspector, dealer, or installer
review your plans before installation.
Note: For flue terminations see page 10.
WARNING
Fire hazard is an
extreme risk
if these clearances
are not adhered to.