16
Changing the oil
Every day before using your pump, check the oil viewing glass at
B
in the bearing housing for damage
and to confirm that there is enough oil in the end shield. The oil should reach the middle of the glass.
l
Check that the drain plug
C
is in place and fully tightened.
l
Open oil vent valve
A
and fill the end shield with suitable oil (see Note below) until it is nearly full.
l
Close oil vent valve
A
.
l
Check the oil level in viewing glass at
B
. Do not allow the level to fall below the viewing glass centre
line.
Note
: When a new pump is supplied, it is filled as standard with Klüberoil 4 UH 1-220 N lubrication oil for
the food and pharmaceutical industries, which is suitable for process temperatures between -30C (-22F)
and 120C (248F).
Filling volumes
Volumes are shown in litres.
C100:
Approx. 0.10
C200:
Approx. 0.10
C250:
Approx. 0.18
C300:
Approx. 0.35
C400:
Approx. 0.45
C500:
Approx. 0.55
C600:
Approx. 1.30
Note:
Dispose of used oil according to local regulations.
Note:
Oil needs to be changed at least once a year.
24