MFP-33 Fireplace Parts Diagrams ....................................................................................................................... Pg. 2, 3
MFP-39/44/49 Fireplace Parts Diagrams ............................................................................................................. Pg. 4, 5
MFP-63 Fireplace Parts Diagrams ....................................................................................................................... Pg. 6, 7
Fireplace Overall Dimensions: MFP-33 and MFP-63 .......................................................................................... Pg. 8
Fireplace Overall Dimensions: MFP-39/44/49 ..................................................................................................... Pg. 9
Fireplace Framing Dimensions ............................................................................................................................ Pg. 10 ~ 12
Safety Information ................................................................................................................................................ Pg. 13
Product Overview ................................................................................................................................................. Pg. 14
Clearances to Combustibles ................................................................................................................................ Pg. 15
Combustible Floor Clearances ............................................................................................................................. Pg. 15
Mason-Lite Fireplace & Chimney System ............................................................................................................ Pg. 15
Chimney System Heights ..................................................................................................................................... P.g 15
Supporting Floor Systems .................................................................................................................................... Pg. 16, 17
Combustible Floor Installations ............................................................................................................................ Pg. 18
What You Will Need ............................................................................................................................................. Pg. 19
Fireplace Assemblies ........................................................................................................................................... Pg. 20~25
Installing Damper and Chimney System .............................................................................................................. Pg. 26
Firestop Radiation Shield ..................................................................................................................................... Pg. 27
Mason-Lite Firebrick Liners .................................................................................................................................. Pg. 27, 28
Fireplace Finishes and Combustible Trim Clearances ......................................................................................... Pg. 28
Installing Outside Air ............................................................................................................................................ Pg. 28, 29
Chimney Pipe ....................................................................................................................................................... Pg. 29
Adding a Gas Pipe ............................................................................................................................................... Pg. 30
Adding Electrical Connection ............................................................................................................................... Pg. 30
Fireplace Grates and Screens ............................................................................................................................. Pg. 30
Mason-Lite Owner’s Operation & Precautions ..................................................................................................... Pg. 30
Starting A Fire and Basic Operation ..................................................................................................................... Pg. 31
Annual Fireplace Maintenance ............................................................................................................................ Pg. 31
Customer Service & Parts Replacement ............................................................................................................. Pg. 31
Appendix I ............................................................................................................................................................ Pg. 32
Appendix II ........................................................................................................................................................... Pg. 33
Limited Warranty .................................................................................................................................................. Pg. 34
CONTENTS
Below is a sample picture of the rating plate that is located inside the lower dome side of your fireplace. Model Number, Date Of
Manufacture and Serial Number should be stamped on the plate where indicated.
DATE
OF MFG.
LARR No. 25924
SERIAL
No.
LISTED MASONRY FIREPLACE SYSTEM COMPLIES WITH APPLICABLE REQUIREMENTS OF UL127 AND ULC610.
Fireplace is designed for installation per the National Fire Protection Association Standard
for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances (NFPA 211).
MODEL
No.:
MFP39
MFP33
MFP44
MFP49
DO NOT REMOVE THIS LABEL
WARNING:
Use only approved,
listed Chimney Pipe as follows:
MFP33/39/44:
UL103-12”-Class A
(DM12-12”, FMI 12” chimneys).
MFP49:
UL103-14”-Class A
Please refer to pipe manufacturer’s
installation instructions.
Chimney Height:
Max.: 40 ft.
Min.: 14 ft.
(17 ft. with 1 or 2 offset
sections maximum)
!
WARNING:
THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET.
TO REDUCE THE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE.
!
MFP350_rev C_JUN2015
THIS APPLIANCE NEEDS FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED
SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
MANTEL CLEARANCES
0” - 3” : 1-1/2” MAX. PROJ.
3“ - 12” : 1-1/2“ - 8” MAX. PROJ.
MANTEL ABOVE OPENING:
MIN. - 3” SHEATHING OR
TRIM TO OPENING SIDES 8”
!
WARNING
:
THIS FIREPLACE
HAS BEEN TESTED FOR USE ONLY
WITH APPROVED GLASS DOORS.
TO REDUCE THE RISK OF FIRE OR
INJURY, CONSULT OWNER’S MANUAL.
THIS FIREPLACE IS
DESIGNED FOR USE ONLY
WITH SOLID WOOD LOGS,
PLUMBED LPG OR NG LOG
LIGHTERS OR PLUMBED ANSI
Z21.60 DECORATIVE GAS LOGS.
Consult instructions included with
this firebox for further information.
6. HOLES: 4x Ø0.14 THRU
5. BOXES TO BE STAMPED DURING MANUFACTURE.
4. LARGE TEXT TO BE BOLD UPPERCASE ARIAL, 10 PT. MIN. (WHERE SHOWN).
3. SMALLEST TEXT TO BE ARIAL, 8 PT. MIN (AS SHOWN).
2. ALL TEXT AND GRAPHICS TO BE CLEAR ALUMINUM ON A CONTRASTING, BLACK BACKGROUND.
1. MATERIAL: CLASS IIIA , .020 THICK ALUMINUM RATED AT 302°F (150°C).
NOTES
: UNLESS OTHERWISE SPECIFIED
DESCRIPTION: PLATE, RATING, STANDARD
P/N: MFP350
REVISION: C
REV. DATE: 6/3/2015
LAST MODIFIED BY: CB
FILENAME: MFP350_PLATE, RATING, STD_rev C
Report
No. 08-154
ICC Evaluation
Services Report
No. 2401
MFP63
MFP63:
UL103-16”-Class A
FIREPLACE CLEARANCES TO COMBUSTIBLES:
UNIT FRONT, SIDES, REAR..............................................
2” (51 mm)
COMBUSTIBLE FLOOR
(MFP33/39/44/49)
................
6” (203 mm)
COMBUSTIBLE FLOOR
(MFP63)...............
................
8” (203 mm)
COMBUSTIBLE SHEATHING ABOVE OPENING TOP...1
8” (457 mm)
SHEATHING OR TRIM TO OPENING SIDES...................
8” (203 mm)
MANTLE ABOVE OPENING...........................................
12” (305 mm)
OPENING TO SIDE WALL..............................................
24” (610 mm)
HEARTH EXTENSION BEYOND FRONT.......................
20” (508 mm)
HEARTH EXTENSION BEYOND SIDES........................
12” (305 mm)
INSULATION FROM FIREBOX.........................................
2” (51 mm)
MFI
Masonry
Fireplace
Industries, LLC
6391 Jurupa Ave.
Riverside, CA 92514
See MFI’s installation and operating instructions for
this model. Contact local building officials about
restrictions and installation specifications in your area.
Tested &
Listed By
PFS
®
US
C
6.5”
6.25”
.12”
4.25”
4.00”