Masibust VT7S12E User Manual Download Page 24

                                                                                                              VIBRATION TRANSMITTER-VT7S12E

 

                                                                                                                                              Ref No: mVTD/om/201

                                                                                                                                         Issue No: 02          

User’s Manual 

- 24 - 

 

63 

SKIP-Channel CH - 2 

40063 

INT 

R/W 

64 

SKIP-Channel CH - 3 

40064 

INT 

R/W 

65 

SKIP-Channel CH - 4 

40065 

INT 

R/W 

66 

RLY Latch 

40066 

INT 

R/W 

Table 33 

67 

RLY Group 

40067 

INT 

R/W 

Table 27 

68 

Scan Rate 

40068 

INT 

250 

R/W 

69 

Auto CJC 

40069 

INT 

R/W 

70 

Fix CJC 

40070 

INT 

60.0 

R/W 

71 

Machine ID 

40071 

INT 

247 

R/W 

72 

Baud Rate 

40072 

INT 

R/W 

Table 34 

73 

Parity/Stop Bit 

40073 

INT 

R/W 

Table 35 

74 

Timeout 

40074 

INT 

10 

60 

R/W 

85 

Retransmission Open Sensor AO Card-1 

40085 

INT 

R/W 

Table 36 

86 

Retransmission Open Sensor AO Card-2 

40086 

INT 

R/W 

87 

Retransmission Type AO Card-1 

40087 

INT 

R/W 

Table 37 

88 

Retransmission Type AO Card-2 

40088 

INT 

R/W 

89 

Retransmission Direction AO Card-1 

40089 

INT 

R/W 

Table 38 

90 

Retransmission Direction AO Card-2 

40090 

INT 

R/W 

91 

Retransmission Mapping CH-1 

40091 

INT 

R/W 

92 

Retransmission Mapping CH-2 

40092 

INT 

R/W 

93 

Retransmission Mapping CH-3 

40093 

INT 

R/W 

94 

Retransmission Mapping CH-4 

40094 

INT 

R/W 

95 

Retransmission Value AO Card-1 

40095 

INT 

R/W 

Table 39 

96 

Retransmission Value AO Card-2 

40096 

INT 

R/W 

98 

Password 

40098 

INT 

9999 

R/W 

99 

Over Limit 

40099 

INT 

10 

R/W 

100 

Under Limit 

40100 

INT 

10 

R/W 

101 

 Digital Filter 

40101 

INT 

R/W 

102 

Slot 

40102 

INT 

60 

R/W 

 

Table 19 Modbus Parameter Details for Input Register 

 

Sr. 

No. 

Parameter 

Absolute 

Address 

Parameter 

Type 

Min 

Value 

Max Value 

Access 

Type 

NOTE 

Calibration Password 

49001 

INT 

65000 

 

Zero Calibration Channel-1 

49003 

INT 

 

Zero Calibration Channel-2 

49004 

INT 

 

Zero Calibration Channel-3 

49005 

INT 

 

Zero Calibration Channel-4 

49006 

INT 

 

11 

Span Calibration Channel-1 

49011 

INT 

 

12 

Span Calibration Channel-2 

49012 

INT 

 

13 

Span Calibration Channel-3 

49013 

INT 

 

14 

Span Calibration Channel-4 

49014 

INT 

 

19 

Zero Calibration AO Card-1 

49019 

INT 

 

20 

Zero Calibration AO Card-2 

49020 

INT 

 

21 

Span Calibration AO Card-1 

49021 

INT 

 

22 

Span Calibration AO Card-1 

49022 

INT 

 

 

Table 20 Modbus Parameter Details for Calibration Register 

 

 

Modbus Parameter Details for Read Output Status Register: 

 

Sr.
No 

Parameter 

Absolute 

Address 

Parameter 

Type 

Access 

Type 

Alarm.1 Channel-1 

BIT 

Alarm.1 Channel-2 

BIT 

Alarm.1 Channel-3 

BIT 

Alarm.1 Channel-4 

BIT 

Alarm.2 Channel-1 

BIT 

Alarm.2 Channel-2 

BIT 

Summary of Contents for VT7S12E

Page 1: ...02 User s Manual 1 USER MANUAL VT7S12E VIBRATION TRANSMITTER Masibus Automation Instrumentation Pvt Ltd B 30 GIDC Electronics Estate Sector 25 Gandhinagar 382044 Gujarat India 91 79 23287275 79 91 79...

Page 2: ...vironmental specification 7 3 6 Output relay specification 7 3 7 Analog output specification 7 3 8 Rs 485 communication specification optional 7 3 9 Buffer output specification 7 3 10 Signal isolation...

Page 3: ...Register 24 Table 20 Modbus Parameter Details for Calibration Register 24 Table 21 Modbus Parameter Details for Read Output Status Register 25 Table 22 Input Type Selection Table 25 Table 23 Relay Log...

Page 4: ...hould any errors or omissions come to your attention however please inform Masibus Sales office or sales representative Under no circumstances may the contents of this manual in part or in whole be tr...

Page 5: ...ent and temperature rating of the system o Provide power from a single phase instrument power supply If there is a lot of noise in the power line insert an insulating transformer into the primary side...

Page 6: ...1KHz 2 5KHz 10KHz Filter Accuracy 10 of Cut off Frequency Measuring parameter Acceleration Velocity Displacement Measuring Range 1 Acceleration 0 50 g RMS peak derived 2 Velocity 0 100 mm s RMS peak...

Page 7: ...CRC Check 3 9 Buffer output specification No of output Two Output Impedance 100 Ohms Frequency Range 0 5 Hz to 10KHz Accuracy 0 25 of Full Range 3 10 Signal isolations and insulation specification Iso...

Page 8: ...DESCRIPTION MENU ENTER KEY It is used to enter in the sub menu various levels and save the parameters to nonvolatile memory when user setting a proper data by Increment and shift key for parameter con...

Page 9: ...VIBRATION TRANSMITTER VT7S12E Ref No mVTD om 201 Issue No 02 User s Manual 9 6 CONNETION DIAGRAM Figure 2 Connection Diagram of VT7S12E...

Page 10: ...D om 201 Issue No 02 User s Manual 10 7 MENU LAYOUT 7 1 Flow Diagram Vibration Transmitter VT7S12E has a number of software parameters which may or may not be required depending on your particular app...

Page 11: ...LH rLGP SCAn Srno bAud PrSt tout rtos rttP rtdr rtmp CAL pwd 0000 0000 CALZ CALS rtrZ rtrS Procedure for changing setting different values to different channels in all levels is shown in the level 1 H...

Page 12: ...key DATA window shows LVL1 LvL1 message Press MENU key again DATA window shows pwd PWD message press increment key twice to select password and then press MENU key to enter into Level 1 DATA window s...

Page 13: ...et to Al Rldl rLdL Relay Delay Applicable for All Relay 1 to 99 seconds 1 second for All Relay Rlos rLoS Relay Open sensor Applicable for All Relay up Dn UP Down 0 DOW N 1 UP Up Scale for All Relay Rl...

Page 14: ...ll be assigned channel wise and all assignments are remain fixed And Relay type Example Table 10 Relay as Control Output Configuration Detail For Relay functionality Refer Relay outputs Chapter 8 3 LE...

Page 15: ...rd Rtdr rtdr Retransmission direction Dir rev 1 dir 0 rev 1 For Both Output Card Rtmp rt mp Retransmission mapping See Table 8 Rtrd rtrd Retransmission Channel Value Max Min 1 Max 0 Min 1 For Both Out...

Page 16: ...nsor type selected Rtr Z rtr Z Retransmission voltage and current Zero calibration Depending on Retransmission type selected Rtr S rtr S Retransmission voltage and current Span calibration Depending o...

Page 17: ...crosses the set point For heating control the output is on when the temperature is below the set point and off above set point Since the temperature crosses the set point to change the output stage t...

Page 18: ...tch No Lamp Off Steady Off Steady Off Off Relay Off On Off On Off Off Trip Lamp Off Steady Off Off Steady Off Relay Off On Off Off On Off Alarm al2 Momemtary alarm when in abnormal condition ack not p...

Page 19: ...dy Off Steady Steady Off Off Relay Off On Off On Off Off Off Trip Lamp Off Steady Off Off Steady Steady Off Relay Off On Off Off On On Off Alarm al2 Maintained alarm when in abnormal condition ack is...

Page 20: ...condition after abnormal has already occurred means it remains in the previous state If previous state is ON then it will remain ON and the same case for OFF condition Pressing Shift Decrement key fo...

Page 21: ...he DATA window to indicate that it is doing the necessary calculations Depending on the situation this process may take few seconds to calibrate Zero and Span calibration is over In case the controlle...

Page 22: ...us Parameter Details for Process Value Modbus values for OPEN OVER UNDER and SKIP Conditions Table 18 Details of abnormal Conditions of Process Value CODE NAME Function 01 Illegal function The functio...

Page 23: ...0029 INT R W 30 Range Low CH 2 40030 INT R W 31 Range Low CH 3 40031 INT R W 32 Range Low CH 4 40032 INT R W 33 Decimal Point CH 1 40033 INT 0 3 R W 34 Decimal Point CH 2 40034 INT 0 3 R W 35 Decimal...

Page 24: ...AO Card 1 40095 INT 0 1 R W Table 39 96 Retransmission Value AO Card 2 40096 INT 0 1 R W 98 Password 40098 INT 0 9999 R W 99 Over Limit 40099 INT 0 10 R W 100 Under Limit 40100 INT 0 10 R W 101 Digit...

Page 25: ...nput Type I P no Type Display Zero Span Resolution Acceleration RMS 1 A rm 0 50 0 0 1 Acceleration PEAK 2 A pk 0 50 0 0 1 Acceleration PEAK PEAK 3 A pp 0 50 0 0 1 Velocity RMS 4 V rm 0 100 0 0 1 Veloc...

Page 26: ...tch selection Modbus Index Parameter Value Modbus Index Parameter Value Modbus Index Parameter Value 0 Low ON 0 High Very High 0 OFF 1 High ON 1 Low Very Low 1 ON 2 High LOW Table 34 Baud Rate for Com...

Page 27: ...l display readings above 5 of display range then after it will show OVER UNDR message until value crosses maximum value of Sensor range OVER UNDER condition is applicable for RTD input types only Proc...

Page 28: ...CTION OPEN OVER ERROR 4 20 mA PV UP DIR 21 6 20 8 PV DOWN REV 20 8 3 2 PV UP REV 2 4 3 2 PV DOWN DIR 2 4 20 8 Table 41 Retransmission Output during Open Over Condition NOTE For Retransmission output t...

Page 29: ...ransmitter power follow the measures in the procedure below If a problem appears complicated contact our sales representative Masibus Automation Instrumentation Pvt Ltd Customer Support Division B 30...

Reviews: