![Masibust VT7S12E User Manual Download Page 12](http://html1.mh-extra.com/html/masibust/vt7s12e/vt7s12e_user-manual_1735161012.webp)
VIBRATION TRANSMITTER-VT7S12E
Ref No: mVTD/om/201
Issue No: 02
User’s Manual
- 12 -
7.2 Menu Parameters
Run Mode:
Following parameters can view or change during run time.
Immediately after powering, unit will run in Auto Mode. In auto mode channel will scan automatically according to scan
time selection (1-250 second).
By pressing
INCREMENT Key
in run mode, Channel number scanning on display is stopped. By pressing increment key
again, we can change channel number manually.
By pressing
SHIFT/DECREMENT Key
in run mode, relay acknowledgement can be done.
By pressing
ESCAPE Key
after going into the Manual Mode unit comes back to run mode.
Other Modes:
For entering in Menu press Enter key in RUN mode. There are total Five modes in menu. By pressing increment or decrement
key mode can be changed. To enter into any mode press enter key again.
1. Level
– 1
2. Level
– 2
3. Level
– 3
4. Calibration Mode
5. Factory Reset Parameter
The table below show the description and menu detail of the all the modes. In general to enter into any menu or to edit sub
menu, press enter key, to change the submenu parameter press increment or decrement key. To come out from any menu
press esc key.
1. Level
– 1 :
Pressing MENU key DATA window shows
LVL1
(LvL1) message. Press MENU key again DATA window shows
pwd
(PWD)
message, press increment key twice to select password and then press MENU key to enter into Level-1. DATA window shows
SP.1
(SP.1) message and by pressing increment key, DATA window shows Set Point-1 Value. Use INC and SHIFT key to
modify value. OR press MENU key again to change Set-point 1 for Channel 2. ESCAPE KEY is used to come out SP.1
L E V E L 1
Parameter
(DATA window)
S e t t i n g n a m e a n d d e s c r i p t i o n
D e f a u l t v a l u e
S h o w s o n l y
i f
Symbol
Name
Pwd
(PWD)
L e v e l - 1 P a s s w o r d
0 t o 9 9 9 9
0 0 0 0
-
Sp
.1
(SP.1)
T a r g e t S e t p o i n t - 1
S e t P o i n t - 1 f o r A l l C h a n n e l
5 0 . 0
-
SP
.2
(SP.2)
T a r g e t S e t p o i n t - 2
S e t P o i n t - 2 f o r A l l C h a n n e l
5 0 . 0
R e l a y g r o u p
2 i s
s e l e c t e d
SP
.3
(SP.3)
T a r g e t S e t p o i n t - 3
S e t P o i n t - 3 f o r A l l C h a n n e l
5 0 . 0
R e l a y g r o u p
1 i s
s e l e c t e d
SP
.4
(SP.4)
T a r g e t S e t p o i n t - 4
S e t P o i n t - 4 f o r A l l C h a n n e l
5 0 . 0
R e l a y g r o u p
1 i s
s e l e c t e d
Hys
(HYS)
H y s t e r e s i s
H y s t e r e s i s f o r A l l C h a n n e l
1 . 0
-
Table 5 Level
– 1 Parameter description
2. LEVEL
– 2 :
Pressing MENU key DATA window shows
LvL2
(LvL2) message. Press MENU key again DATA window shows
pwd
(PWD)
message, press increment key twice to select password and then press MENU key to enter into Level-2. Following parameters
can be configured in LEVEL
– 2.
L E V E L 2 :
P a r a m e t e r
( D A T A W i n d o w )
S e t t i n g n a m e a n d d e s c r i p t i o n
D e f a u l t v a l u e
S h o w s o n l y
i f
Symbol
Name
pwd
(PWD)
L e v e l - 2
P a s s w o r d
0 t o 9 9 9 9
0 0 0 0
-