IS 9
- 29
GB
GB
RETE
MAINS
RESEAU
CARICO
LOAD
CHARGE
2
3
1
Feedback to utility. Feedback voltage may cause
serious injury or death.
Connect the generator to the electrical systemof the
structure/boat only through an approved electrical
system and after opening the main switch of the
structure/boat.
The feedback circuit may cause serious injury or death
of the personnel working on the power lines and/or
personnel near the working area.
- Make sure that the sum of the generator loads doesn't
overcome the nominal power of the generator group.
- Despite the group is provided with a thermal switch
(
rif.1
), it's recommend to interpose magnetothermal
protections or similar between generator and electric
users, according to the following table.
3.7.4 G
ENERATOR
-
NETWORK
SWITCHING
A switch must be interposed on the utility line to allow
switching the utilities from the generator to an external
power supply line.
The switch must be dimensioned on the basis of the
entity of the loads involved;a broad diagram is shown
in
ref.2
.
Do not connect the generator to a public electrical
system (e.g. wharfs, ports, houses, other boats,
etc.).
The feedback circuit may cause serious injury or
death of the personnel working on the power lines
and/or the personnel near the working area.
The generator may only be installed by qualified
technicians. Malfunctioning due to improper
installation may cause injury or death.
Do not modify the default electrical connections
for other applications. If necessary, contact our
distributors.
3.7.5 E
MERGENCY
S
TOP
The generator can be stopped by setting the switch
(
ref.3
) to the
“OFF”
position.
Summary of Contents for IS 9
Page 2: ...IS 9 2 I I ...
Page 46: ...IS 9 2 GB GB ...