5.6 Installer Mode
SECTION 5. Control Display and Operation
Index Numbers
Parameters
Description
1: EH
History entry
History fault code (E0~E9)
2: cE
Clear Error History
Clearing of error History buffer
3: In
System initialize
System initialize to default
4: Fu
Flow unit
L/m or GPM
5: FH
Max fan
Maximum fan parameter calibration
6: FL
Min fan
Minimum fan parameter calibration
7: dr
Reset Number of Ignition
Reset Number of Ignition
8: dl
Maximum fan
Adjust to maximum fan value(default: 0)
9: HA
High Altitude Settings
Choose from 0-2, 2-5, 5-8, and 8-10 (thousands) ft
of altitude.
These changes are to be made only by a qualified technician.
To c hange any of the Installer Parameters,
Start by turning
OFF
the Power
to the
Display Control.
Then, with the power OFF, Press and HOLD (5 seconds) the Button B
to get into the Installer Mode.
Rotate Dial E until you find the Installer Parameter that you wish to change. Tap Dial E to enter that Parameter.
Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.
Finish by pressing button B