MAS DAF ENDURO 100 Lite Operating Manual Download Page 14

                                                                                                                                                                           

 

Mas Grup

 

12 

 

INDEX 

 

 

 

 

 

         

Page No

 

Introduction 

 

 

 

 

12 

1. 

Areas Of Usage 

 

 

 

12 

2. 

Transportation   

 

 

 

12 

3. 

The Issues To Be Cared During Commissioning 
Of The Pump   

 

 

 

12 

4. 

The Size Measures Of Submersible Pumps   

13 

5. 

Necessary Precautions For Pump Performance 
And Energy Conservation  

 

 

13 

6. 

Assembly Drawing 

 

 

 

13 

7. 

Starting The Pump 

 

 

 

14 

8. 

Operating Of Float Switch  

 

 

14 

9. 

Maintenance   

 

 

 

14 

9.1. 

Monthly Maintenance 

 

 

14 

9.2. 

Yearly Maintenance 

 

 

14 

9.3. 

Thermal Protectional 

 

 

14 

9.4. 

Periodic Maintenance 

 

 

15 

10. 

Failures, Causes And Precautions   

 

15 

11. 

Failures, Causes And Precautions (Table) 

 

16 

12. 

List Of Components 

 

 

 

17 

12.1. 

ENDURO Lite 50 Disassembly Photo   

17 

12.2. 

ENDURO Lite 100-150 Disassembly Photo 

18 

12.3. 

ENDURO Lite 150F Disassembly Photo  

19 

12.4. 

ENDURO Lite 150S Disassembly Photo 

20 

12.5. 

ENDURO Lite 200S Disassembly Photo 

21 

13. 

Power Cable Selection Chart 

 

 

22 

14. 

ENDURO Lite Series Bearing And  
Mechanical Seal Table   

 

 

22 

 

INTRODUCTION 

 

 

Dear Customer, 
Firstly we thank you to prefer MAS DAF brand. 
Make  sure  to  use  the  guide  points  to  ensure  more  effciently  and 
longer work of your pump. 
If you do not take into consideration the issues in the user’s guide, your 
pump will be outside the scope of guarantee. 
Rightly  selected  and  properly  used  pump  works  for  a  long  time 
without any break- downs and problems. 
Read and perform the rules and instructions in this manual carefully for 
the pump in order to work without breakdowns and problems. 
Keep the operating manual as long as you usage the pump. 
Do not work the pump out of the informati- on is given. 
Pay attention to the label values while usage the pump. 
 

The Signs Used in This Operation Manual 

  

  Read the instructions carefully in this operating manual 

and keep it for your future reference. 

  Warning sign against the electrical risks 

 

  Sign for the operator’s safety. 

 
 

1.  AREAS OF USAGE

 

 
ENDURO Lite 50, ENDURO Lite 100, ENDURO Lite 150, ENDURO Lite 
150S,  ENDURO  Lite  200S,  ENDURO  Lite  150F  series  of  submersible 
pumps  can  be  used  in  dirty  water  supply,  in  pools  and  backwater 
evacuations in buildings. 
 

LIFETIME IS 5 YEARS 

 
 
 

2.  TRANSPORTATION

 

 
The  pumps  are  dispatched  form  our  factory  as  ready  for  working. 
Place the pumps during transportation in a  way in  which they are 
not  harmed  while  they  are  loaded  and  unloaded  from  the 
transportation  vehicle.  Do  not  drop  the  pump  on  ground  while 
carrying it with or without packing, do not place any weights on it, 
be careful not to harm energy cable. 
 

CAUTION 

 

During carryings do not lift the pump from its energy cable. 

 

3.  THE ISSUES TO BE CARED DURING 

COMMISSIONING OF THE PUMP

 

 

1. 

Make the electrictiy connection of the pump to an electricity technician 
or a qualified electrician. 

2. 

Pump must be grounded while electric connection is making (for life 
security) Pump should work with leakage current fuse max 30 mA. 

3. 

Assemble the pump according to Figure 1. 

4. 

If  the  pump  installation  will  be  done  with  water  piper  or  sleeve,  be 
careful  not  to  excess  clamp,  otherwise  it  will  cause  cracking  in  the 
output of the pump. 

5. 

Do  not  certainly  hang  down  the  pump  from  its  energy  cable,  use 
suspension cable. 

6. 

If the distance between the pump working area is away from energy 
network or additional coupling to power cable is needed, for the cable 
selection  (section)  you  can  utilize  the  electrial  cable  selection  table 
which is on page 22. 

7. 

All  pumps  should  be  used  in  appropriate  water  level  and  suitable to 
their protection system. 

8. 

Pump has to be fastened with a rope or chan which can be the weight 
of pump and installment connection of pump is made and lifted down 
to weller sewage. 

9. 

Use  the  pump  after  reclaim  the  borehole  if  there  is  massive 
particulars and extremely sludges in the borehole that can be bung up 
temped the pump. 

10. 

Check  whether  there  is  ripped,  hole  or  disintegration  on  the  energy 
cable before starting the pump. 

11. 

Do not start single phase pumps by inserting to the three phase plug. 

12. 

Do  not  use  the  pump  in  the  liquid  types  of  acid,  olive  oil  and 
petroleum. 

13. 

Install the energy cable to the network, mounted as close as the wall. 

14. 

Do not use the pump at water temperature higher than 30°C. 

15. 

Do not start the pump in low voltages.  

16. 

Pay attention to water hose not to break in 90° while pump is working. 

17. 

Do not touch the pump or water while pumpis working. 

18. 

Do  not  connect  the  float  switch  of  the  pump,  which  used  for 
evacuation  of  backwater,  to  the  cable  in  the  aim  of  finishing  water. 
Otherwise  pump  motor may  be  burned.  Pump should  be completely 
underwater. 

19. 

Do not start the pump when it freezes in water months. 

20. 

Do not certainly start the pump without water. 

21. 

Wait few sencods for the pump to come to surface level, after putting 
down the pump in the well and starting. 

 

CAUTION 

 

Pump assembly 

operatıon range ıs 210

-

230 v ın monophase models 

and 380 v ın

 threephase models. 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for DAF ENDURO 100 Lite

Page 1: ...Revizyon No 02 Haziran 2018 Revision No 02 June 2018 Dalg Pompalar Submersible Pumps ENDURO Lite Serisi ENDURO Lite SERIES KULLANIM BAKIM K TAP I I OPERATING MANUAL...

Page 2: ...s Y netmelikler 2006 42 EC Machinery Directive 2006 42 AT Makine Emniyeti Y netmeli i 2014 35 EU Low Voltage Directive 2014 35 AB Al ak Gerilim Y netmeli i 2014 30 EU Electromagnetic Compatibility Dir...

Page 3: ...rmeyiniz zerine a rl k koymay n z enerji kablosunun hasar g rmemesine dikkat ediniz D KKAT Ta ma esnas nda pompay enerji kablosundan kald rmay n z 3 POMPAYI LETMEYE ALMADA D KKAT ED LMES GEREKL HUSUS...

Page 4: ...u tesisat n verimi 50 olacakt r 2 Tesisatta kullan lan dirsek ve vana say s ne kadar az olursa s rt nme kayb i in boru se imi do ru yap ld takdirde d k KW l pompa ideal olacakt r 3 Pompalar da her mak...

Page 5: ...c ortamlarda ve s v larda kesinlikle kullanmay n z Boruda dirsek olmamas na dikkat edilmelidir aksi halde pompan n verimi d er Emin olmad n z durumlarda mutlaka yetkili servisi veya firmam z aray n z...

Page 6: ...etli elektrik i veya servis taraf ndan kontrol edilmelidir 3 Mekanik Donan m Kontrol Motor uzun s re kullan lmayacaksa en az ayda bir kez motor k sa s reli al t r lmal d r 4 Pompan n periyodik bak m y...

Page 7: ...arsa giderilmelidir Termik e basarak pompa tekrar devreye al nmal d r Kapasite d k veya pompa su basm yorsa Basma borusu t kal d r Basma borusu geri y kama yap larak temizlenmelidir Manometrik y ksekl...

Page 8: ...ulpu 4 Kablo Lasti i 5 Flat r 6 Pompa G vdesi 7 Kondansat r 8 Kondansat r Tutucu 9 st Rulman Kapa 10 Stator 11 Rulman 12 Rotor Drenaj 13 Mil 14 Rulman Bask Yay 15 Ya Ke esi 16 Alt Rulman Kapa 17 O Rin...

Page 9: ...astik Pulu 4 Ta ma Kulpu 5 Kablo Lasti i 6 Pompa G vdesi 7 Flat r 8 Kondansat r 9 Kondansat r Tutucu 10 Rulman Kapa 11 Rulman Bask Yay 12 Rulman 13 Mil 14 Rotor 15 Rulman 16 Stator 17 Motor O Ringi 18...

Page 10: ...ik Rekoru 4 Ta ma Kulpu 5 Kablo Lasti i 6 Pompa G vdesi 7 Flat r 8 Kondansat r 9 Kondansat r Tutucu 10 YSB M4x6 11 Rulman Kapa 12 Rulman Bask Yay 13 Rulman 14 Rotor 15 Rulman 16 Mil 17 Stator 18 O Rin...

Page 11: ...praklama Vidas 17 Motor O Ringi 18 st Rulman Kapa 19 Motor G vdesi 20 Stator 21 st Rulman 22 Mil 23 Rotor 24 Alt Rulman 25 Motor O Ringi 26 Ya Ke esi 27 Motor Saplamas 28 Alt Rulman Kapa 29 Alt Kapak...

Page 12: ...mpa Saplamas 9 Di i Soket 10 Kablo Soket Vidas 11 Kablo Soketi 12 Flat r 13 Kondansat r Kutu O Ringi 14 Soket O Ringi 15 st Rulman Kapa 16 K r Tapa 17 K r Tapa Contas 18 Motor G vdesi 19 Stator 20 Rul...

Page 13: ...5 360 3 3 65 90 165 255 390 2 2 4 45 65 110 180 255 4 5 5 35 45 85 135 195 330 5 5 7 5 35 70 110 165 270 7 5 10 40 65 100 160 11 15 25 45 65 110 14 ENDURO L TE SER S RULMAN KE E MEKAN K SALMASTRA TABL...

Page 14: ...on ground while carrying it with or without packing do not place any weights on it be careful not to harm energy cable CAUTION During carryings do not lift the pump from its energy cable 3 THE ISSUES...

Page 15: ...selection will made correct for fricition loss 3 As the machines pump may be wear waray as the time passses pump flow and delivery head decreasses 4 Energy conversation will increase with our attenti...

Page 16: ...cact tips which engaged with each other will open the circuit as an electical in Figure 4 and stop operating of the pump Float switch will prevent the burning of the motor by blocking theworking witho...

Page 17: ...it is not hanged out to the sides Look at Figure 1 2 Check out the water level If pump water level is normal there may be muddy or wooden components wedged into the pump impeller Before interfering co...

Page 18: ...ump should be rerun by pushing thermic If there is low capacity or the pump does not flow water Delivery pipe is restricted Clean the delivery pipe with return cleaning Manometric Hm head is very high...

Page 19: ...4 Cable Seal 5 Float Switch 6 Pump Body 7 Capasitor 8 Capasitor Holder 9 Top Bearing Cover 10 Stator 11 Bearing 12 Rotor Drainage 13 Shaft 14 Bearing Pressure Spring 15 Oil Seal 16 Bottom Bearing Cove...

Page 20: ...lake 4 Carrying Handle 5 Cable Seal 6 Pump Body 7 Float Switch 8 Capasitor 9 Capasitor Holder 10 Bearing Cover 11 Bearing Pressure Spring 12 Bearing 13 Shaft 14 Rotor 15 Bearing 16 Stator 17 Motor O R...

Page 21: ...4 Carrying Handle 5 Cable Seal 6 Pump Body 7 Float Switch 8 Capasitor 9 Capasitor Holder 10 YSB M4x6 11 Bearing Cover 12 Bearing Pressure Spring 13 Bearing 14 Rotor 15 Bearing 16 Shaft 17 Stator 18 O...

Page 22: ...Grounding Screw 17 Motor O Ring 18 Top Bearing Cover 19 Motor Body 20 Stator 21 Top Bearing 22 Shaft 23 Rotor 24 Bottom Bearing 25 Motor O Ring 26 Oil Seal 27 Motor Stud 28 Bottom Bearing Cover 29 Bot...

Page 23: ...d 9 Female Socket 10 Cable Socket Screw 11 Cable Socket 12 Float Switch 13 Capacitor Box O Ring 14 Socket O Ring 15 Top Bearing Cover 16 Blind Plug 17 Bling Plug Gasket 18 Motor Body 19 Stator 20 Bear...

Page 24: ...60 3 3 65 90 165 255 390 2 2 4 45 65 110 180 255 4 5 5 35 45 85 135 195 330 5 5 7 5 35 70 110 165 270 7 5 10 40 65 100 160 11 15 25 45 65 110 14 ENDURO LITE SERIES BEARING AND MECHANICAL SEAL TABLE Pu...