Mas Grup
12
INDEX
Page No
Introduction
12
1.
Areas Of Usage
12
2.
Transportation
12
3.
The Issues To Be Cared During Commissioning
Of The Pump
12
4.
The Size Measures Of Submersible Pumps
13
5.
Necessary Precautions For Pump Performance
And Energy Conservation
13
6.
Assembly Drawing
13
7.
Starting The Pump
14
8.
Operating Of Float Switch
14
9.
Maintenance
14
9.1.
Monthly Maintenance
14
9.2.
Yearly Maintenance
14
9.3.
Thermal Protectional
14
9.4.
Periodic Maintenance
15
10.
Failures, Causes And Precautions
15
11.
Failures, Causes And Precautions (Table)
16
12.
List Of Components
17
12.1.
ENDURO Lite 50 Disassembly Photo
17
12.2.
ENDURO Lite 100-150 Disassembly Photo
18
12.3.
ENDURO Lite 150F Disassembly Photo
19
12.4.
ENDURO Lite 150S Disassembly Photo
20
12.5.
ENDURO Lite 200S Disassembly Photo
21
13.
Power Cable Selection Chart
22
14.
ENDURO Lite Series Bearing And
Mechanical Seal Table
22
INTRODUCTION
Dear Customer,
Firstly we thank you to prefer MAS DAF brand.
Make sure to use the guide points to ensure more effciently and
longer work of your pump.
If you do not take into consideration the issues in the user’s guide, your
pump will be outside the scope of guarantee.
Rightly selected and properly used pump works for a long time
without any break- downs and problems.
Read and perform the rules and instructions in this manual carefully for
the pump in order to work without breakdowns and problems.
Keep the operating manual as long as you usage the pump.
Do not work the pump out of the informati- on is given.
Pay attention to the label values while usage the pump.
The Signs Used in This Operation Manual
Read the instructions carefully in this operating manual
and keep it for your future reference.
Warning sign against the electrical risks
Sign for the operator’s safety.
1. AREAS OF USAGE
ENDURO Lite 50, ENDURO Lite 100, ENDURO Lite 150, ENDURO Lite
150S, ENDURO Lite 200S, ENDURO Lite 150F series of submersible
pumps can be used in dirty water supply, in pools and backwater
evacuations in buildings.
LIFETIME IS 5 YEARS
2. TRANSPORTATION
The pumps are dispatched form our factory as ready for working.
Place the pumps during transportation in a way in which they are
not harmed while they are loaded and unloaded from the
transportation vehicle. Do not drop the pump on ground while
carrying it with or without packing, do not place any weights on it,
be careful not to harm energy cable.
CAUTION
During carryings do not lift the pump from its energy cable.
3. THE ISSUES TO BE CARED DURING
COMMISSIONING OF THE PUMP
1.
Make the electrictiy connection of the pump to an electricity technician
or a qualified electrician.
2.
Pump must be grounded while electric connection is making (for life
security) Pump should work with leakage current fuse max 30 mA.
3.
Assemble the pump according to Figure 1.
4.
If the pump installation will be done with water piper or sleeve, be
careful not to excess clamp, otherwise it will cause cracking in the
output of the pump.
5.
Do not certainly hang down the pump from its energy cable, use
suspension cable.
6.
If the distance between the pump working area is away from energy
network or additional coupling to power cable is needed, for the cable
selection (section) you can utilize the electrial cable selection table
which is on page 22.
7.
All pumps should be used in appropriate water level and suitable to
their protection system.
8.
Pump has to be fastened with a rope or chan which can be the weight
of pump and installment connection of pump is made and lifted down
to weller sewage.
9.
Use the pump after reclaim the borehole if there is massive
particulars and extremely sludges in the borehole that can be bung up
temped the pump.
10.
Check whether there is ripped, hole or disintegration on the energy
cable before starting the pump.
11.
Do not start single phase pumps by inserting to the three phase plug.
12.
Do not use the pump in the liquid types of acid, olive oil and
petroleum.
13.
Install the energy cable to the network, mounted as close as the wall.
14.
Do not use the pump at water temperature higher than 30°C.
15.
Do not start the pump in low voltages.
16.
Pay attention to water hose not to break in 90° while pump is working.
17.
Do not touch the pump or water while pumpis working.
18.
Do not connect the float switch of the pump, which used for
evacuation of backwater, to the cable in the aim of finishing water.
Otherwise pump motor may be burned. Pump should be completely
underwater.
19.
Do not start the pump when it freezes in water months.
20.
Do not certainly start the pump without water.
21.
Wait few sencods for the pump to come to surface level, after putting
down the pump in the well and starting.
CAUTION
Pump assembly
operatıon range ıs 210
-
230 v ın monophase models
and 380 v ın
threephase models.