MAS DAF ENDURO 100 Lite Operating Manual Download Page 10

                                                                                                                                                                           

 

Mas Grup

 

 

 

12.3.  ENDURO Lite 150F Demontaj Resmi 

 
 

Parça No

 

Parça Adı

 

Enerji Kablosu 

Difüzör ve Taşıma Kulpu Vidası 

Kablo Lastik Rekoru 

Taşıma Kulpu 

Kablo Lastiği 

Pompa Gövdesi 

Flatör 

Kondansatör 

Kondansatör Tutucu 

10 

YSB M4x6 

11 

Rulman Kapağı 

12 

Rulman Baskı Yayı 

13 

Rulman 

14 

Rotor 

15 

Rulman 

16 

Mil 

17 

Stator 

18 

O-Ring 

19 

Motor Gövdesi 

20 

Yağ Keçesi 

21 

Mekanik Salmastra 

22 

Çark 

23 

Difüzör O-Ringi 

24 

Verici Gövde 

25 

Alıcı Ayak 

26 

Alıcı Ayak Vidası 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Summary of Contents for DAF ENDURO 100 Lite

Page 1: ...Revizyon No 02 Haziran 2018 Revision No 02 June 2018 Dalg Pompalar Submersible Pumps ENDURO Lite Serisi ENDURO Lite SERIES KULLANIM BAKIM K TAP I I OPERATING MANUAL...

Page 2: ...s Y netmelikler 2006 42 EC Machinery Directive 2006 42 AT Makine Emniyeti Y netmeli i 2014 35 EU Low Voltage Directive 2014 35 AB Al ak Gerilim Y netmeli i 2014 30 EU Electromagnetic Compatibility Dir...

Page 3: ...rmeyiniz zerine a rl k koymay n z enerji kablosunun hasar g rmemesine dikkat ediniz D KKAT Ta ma esnas nda pompay enerji kablosundan kald rmay n z 3 POMPAYI LETMEYE ALMADA D KKAT ED LMES GEREKL HUSUS...

Page 4: ...u tesisat n verimi 50 olacakt r 2 Tesisatta kullan lan dirsek ve vana say s ne kadar az olursa s rt nme kayb i in boru se imi do ru yap ld takdirde d k KW l pompa ideal olacakt r 3 Pompalar da her mak...

Page 5: ...c ortamlarda ve s v larda kesinlikle kullanmay n z Boruda dirsek olmamas na dikkat edilmelidir aksi halde pompan n verimi d er Emin olmad n z durumlarda mutlaka yetkili servisi veya firmam z aray n z...

Page 6: ...etli elektrik i veya servis taraf ndan kontrol edilmelidir 3 Mekanik Donan m Kontrol Motor uzun s re kullan lmayacaksa en az ayda bir kez motor k sa s reli al t r lmal d r 4 Pompan n periyodik bak m y...

Page 7: ...arsa giderilmelidir Termik e basarak pompa tekrar devreye al nmal d r Kapasite d k veya pompa su basm yorsa Basma borusu t kal d r Basma borusu geri y kama yap larak temizlenmelidir Manometrik y ksekl...

Page 8: ...ulpu 4 Kablo Lasti i 5 Flat r 6 Pompa G vdesi 7 Kondansat r 8 Kondansat r Tutucu 9 st Rulman Kapa 10 Stator 11 Rulman 12 Rotor Drenaj 13 Mil 14 Rulman Bask Yay 15 Ya Ke esi 16 Alt Rulman Kapa 17 O Rin...

Page 9: ...astik Pulu 4 Ta ma Kulpu 5 Kablo Lasti i 6 Pompa G vdesi 7 Flat r 8 Kondansat r 9 Kondansat r Tutucu 10 Rulman Kapa 11 Rulman Bask Yay 12 Rulman 13 Mil 14 Rotor 15 Rulman 16 Stator 17 Motor O Ringi 18...

Page 10: ...ik Rekoru 4 Ta ma Kulpu 5 Kablo Lasti i 6 Pompa G vdesi 7 Flat r 8 Kondansat r 9 Kondansat r Tutucu 10 YSB M4x6 11 Rulman Kapa 12 Rulman Bask Yay 13 Rulman 14 Rotor 15 Rulman 16 Mil 17 Stator 18 O Rin...

Page 11: ...praklama Vidas 17 Motor O Ringi 18 st Rulman Kapa 19 Motor G vdesi 20 Stator 21 st Rulman 22 Mil 23 Rotor 24 Alt Rulman 25 Motor O Ringi 26 Ya Ke esi 27 Motor Saplamas 28 Alt Rulman Kapa 29 Alt Kapak...

Page 12: ...mpa Saplamas 9 Di i Soket 10 Kablo Soket Vidas 11 Kablo Soketi 12 Flat r 13 Kondansat r Kutu O Ringi 14 Soket O Ringi 15 st Rulman Kapa 16 K r Tapa 17 K r Tapa Contas 18 Motor G vdesi 19 Stator 20 Rul...

Page 13: ...5 360 3 3 65 90 165 255 390 2 2 4 45 65 110 180 255 4 5 5 35 45 85 135 195 330 5 5 7 5 35 70 110 165 270 7 5 10 40 65 100 160 11 15 25 45 65 110 14 ENDURO L TE SER S RULMAN KE E MEKAN K SALMASTRA TABL...

Page 14: ...on ground while carrying it with or without packing do not place any weights on it be careful not to harm energy cable CAUTION During carryings do not lift the pump from its energy cable 3 THE ISSUES...

Page 15: ...selection will made correct for fricition loss 3 As the machines pump may be wear waray as the time passses pump flow and delivery head decreasses 4 Energy conversation will increase with our attenti...

Page 16: ...cact tips which engaged with each other will open the circuit as an electical in Figure 4 and stop operating of the pump Float switch will prevent the burning of the motor by blocking theworking witho...

Page 17: ...it is not hanged out to the sides Look at Figure 1 2 Check out the water level If pump water level is normal there may be muddy or wooden components wedged into the pump impeller Before interfering co...

Page 18: ...ump should be rerun by pushing thermic If there is low capacity or the pump does not flow water Delivery pipe is restricted Clean the delivery pipe with return cleaning Manometric Hm head is very high...

Page 19: ...4 Cable Seal 5 Float Switch 6 Pump Body 7 Capasitor 8 Capasitor Holder 9 Top Bearing Cover 10 Stator 11 Bearing 12 Rotor Drainage 13 Shaft 14 Bearing Pressure Spring 15 Oil Seal 16 Bottom Bearing Cove...

Page 20: ...lake 4 Carrying Handle 5 Cable Seal 6 Pump Body 7 Float Switch 8 Capasitor 9 Capasitor Holder 10 Bearing Cover 11 Bearing Pressure Spring 12 Bearing 13 Shaft 14 Rotor 15 Bearing 16 Stator 17 Motor O R...

Page 21: ...4 Carrying Handle 5 Cable Seal 6 Pump Body 7 Float Switch 8 Capasitor 9 Capasitor Holder 10 YSB M4x6 11 Bearing Cover 12 Bearing Pressure Spring 13 Bearing 14 Rotor 15 Bearing 16 Shaft 17 Stator 18 O...

Page 22: ...Grounding Screw 17 Motor O Ring 18 Top Bearing Cover 19 Motor Body 20 Stator 21 Top Bearing 22 Shaft 23 Rotor 24 Bottom Bearing 25 Motor O Ring 26 Oil Seal 27 Motor Stud 28 Bottom Bearing Cover 29 Bot...

Page 23: ...d 9 Female Socket 10 Cable Socket Screw 11 Cable Socket 12 Float Switch 13 Capacitor Box O Ring 14 Socket O Ring 15 Top Bearing Cover 16 Blind Plug 17 Bling Plug Gasket 18 Motor Body 19 Stator 20 Bear...

Page 24: ...60 3 3 65 90 165 255 390 2 2 4 45 65 110 180 255 4 5 5 35 45 85 135 195 330 5 5 7 5 35 70 110 165 270 7 5 10 40 65 100 160 11 15 25 45 65 110 14 ENDURO LITE SERIES BEARING AND MECHANICAL SEAL TABLE Pu...

Page 25: ...BUL T RK YE TURKEY Tel 90 216 456 47 00 pbx Fax 90 216 455 14 24 Ankara B lge M d rl Ankara Regional Directorate A a ve ler Mah 1329 Sok No 6 9 ve ler ANKARA T RK YE TURKEY Tel 90 312 472 81 60 67 Fax...

Reviews: