background image

Commander

 Universal Control Panel 

5000/5100 Series

Operating Guide P/N 501041-000 Rev B

Marway Power Solutions
1721 S. Grand Ave., Santa Ana, CA 92705
800-462-7929 

 [email protected]

© 2020, Marway Power Systems, Inc. All rights reserved.

Commander™ and Optima™ are trademarks of Marway Power Systems, Inc.

All other trademarks are the property of their respective owners.

Global Support Contacts

Web: 

www.marway.com

Email:  [email protected]

 

[email protected]

Phone:  800-462-7929 (7am–5pm PST)

There may be updates to this documentation and the software it describes at:

http://www.marway.com/commander-epo-panels

Summary of Contents for Commander UCP 5000 Series

Page 1: ...Commander Universal Control Panel 5000 5100 Series Operating Guide and Reference Sep 2020 P N 501041 000 Rev B ...

Page 2: ...Startup 6 3 2 Control Modes and Connector Pins 6 3 2 1 Power On Off Modes 7 3 2 2 EPO Mode 7 3 2 3 Clearing EPO Mode 8 3 3 Control Modes and PDU Behaviors 8 3 3 1 Optima 5 Series PDUs 8 3 3 2 Optima 8 Series PDUs 8 3 3 3 Custom PDUs 9 3 4 Using Aux1 Aux2 Outlets 9 4 Connections 10 4 1 Connecting to PDUs 10 4 2 Remote Status Indication 11 4 3 Connecting Additional EPO Buttons 11 5 Reference 12 6 Sp...

Page 3: ...al cabling Do not open this product as it contains no user serviceable parts inside All service concerns should be directed to Marway Power Solutions If this product is used in a manner which does not comply with this instruction manual the protection provided by the equipment may be impaired All work on connections must be carried out under zero voltage output disconnect and may only be performed...

Page 4: ...power outlets one at the front one at the back All models are constructed of a steel chassis and are designed for fixed mounting within a 1 U rack space in an EIA 310 compliant rack enclosure 1 4 Product Models The products are separated into two families The 5000 series is designed to NEMA conventions and the 5100 series designed to IEC conventions Each of these two families includes models for n...

Page 5: ...k cabinet using an appropriate fastener 3 This product includes a power cord with a plug which is used to disconnect power to the product The facility socket outlet must be installed near the equipment and must be easily accessible 4 Connect the appropriate remote control cables between the product and one or more PDUs 5 Ensure the Control Breaker is in the reset depressed position 6 Connect the p...

Page 6: ...Control Modes and Connector Pins The system has three modes or states of control named On Off and EPO These modes change the state of the Outlet Control Bus pins at the rear of the unit which are then interpreted by the remote EPO controller in a Marway PDU or other equipment with compatible signals The following table summarizes the pin connections during the operating modes UCP State 000 Normall...

Page 7: ...NO models during both On mode and Off mode the Disable signal is normally open There is no connection with Return pins 2 and 3 this is where the model version gets its normally open description For 001 NC models during both On mode and Off mode the Disable signal is normally closed There is a maintained connection with Return pins 2 and 3 this is where the model version gets its normally closed de...

Page 8: ...s varies by model are not subject to the EPO system They will remain powered as long as the PDU is powered even if the EPO button is pressed With the addition of the remote control software the Optima 8 series has an additional facet to consider when the EPO state is activated By default when an EPO event occurs the Optima responds in two ways First the standard EPO control system in the PDU shuts...

Page 9: ...ptima 8 Series PDUs will apply Please read that section for details If the custom PDU does not have RCM networking software with switched outlets then any outlet designed to not react to the EPO system will simply remain on as long as the PDU is powered even when the EPO button is pressed or the EPO Mode switch on the PDU is the Off middle position 3 4 Using Aux1 Aux2 Outlets These two outlets are...

Page 10: ... directly to the UCP is possible using the on board connectors Connectors J1 and J2 are intended to be used to connect to downstream PDUs Shown below are common daisy chain scenarios The left show the Commander s J1 and J2 being used to directly connect to separate PDUs The J2 connection is then used to daisy chain to another PDU using a Y cable The right side shows a classic daisy chain when ther...

Page 11: ...rns the 24 Vdc signal and creates an EPO active state N C Models J3 requires a shorting jumper when no external switches are used Adding switches in series to break Pin1 from Pin 2 creates an EPO active state The voltage rating of connector J3 is a significant change from the legacy UCP 3500 UCP 5000 5100 models use 24 Vdc whereas UCP 3500 models use 20 Vac Internal Power On Pin 3 Return Pin 1 Ena...

Page 12: ...s have them forced on The EPO Reset lamp will be illuminated and the audible alarm will be activated if switch 7 is on 6 EPO status lamp EPO Reset button The lamp will be illuminated whenever the UCP is in an EPO state Pressing the button will turn off the EPO state and put the PDU into a disabled state EPO lamp will not be lit and the audible alarm will be silenced The PDU Power Off lamp will be ...

Page 13: ...trol Bus Aux 2 8 00 1 34 1 44 1 72 0 86 max protrusion without optional shroud 19 00 17 16 9 ft cable 5 15P plug 5000 Dimensions 5000 Electrical 5000 Environment 1U Rack mount chassis Weight approx 9 lbs Front Width 19 00 Chassis Width 17 16 Chassis Height 1 72 Chassis Depth 8 00 Input power rating 120 Vac 50 60 Hz Current Load 12 A continuous 15 A maximum Power consumption without Aux 1 2 1 amp J...

Page 14: ...r Systems Inc All rights reserved Commander and Optima are trademarks of Marway Power Systems Inc All other trademarks are the property of their respective owners Global Support Contacts Web www marway com Email support marway com sales marway com Phone 800 462 7929 7am 5pm PST There may be updates to this documentation and the software it describes at http www marway com commander epo panels ...

Reviews: