RUSH® MH 11 Beam
User Manual
43
Optics
Beam angle .............................................................................................. 2.6
°
Interchangeable Gobos
Acceptable materials............................................ Stainless steel or aluminum
Diameter.......................................14 mm, +0/-0.2 mm (0.55 in., +0/-0.008 in.)
Max. image diameter, metal.................................................. 9.5 mm (0.37 in.)
Thickness, metal .....................................................0.2mm (0.008 in.) nominal
Control and Programming
Control systems.............................................................................. DMX, RDM
DMX channels ...............................................................................................18
Integrated user interface ...................... Control panel with backlit LCD display
DMX compliance ............................................................ USITT DMX512/1990
RDM compliance................................................................. ANSI/ESTA E.120
Construction
Color.........................................................................................................Black
Housing ..........................................High impact flame retardant thermoplastic
IP rating .................................................................................................... IP 20
Installation
Mounting points ..........................Two quarter-turn brackets for rigging clamps
Location................Dry location only, must be fastened to surface or structure
Orientation...................................................................................................Any
Minimum distance to illuminated surfaces .................................... 10 m (33 ft.)
Minimum distance to combustible materials .................................20 cm (8 in.)
Minimum clearance around fans and vents ................................50 cm (20 in.)
Connections
AC power input/output............................................ Neutrik PowerCon TRUE1
DMX & RDM data in/out...........................................3-pin & 5-pin locking XLR
Electrical
AC power............................................................100-240 V nominal, 50/60 Hz
Typical half-cycle RMS inrush current ....................................................... 16A
Power supply unit................................... Auto-ranging electronic switch mode
Fuse ..........................................................................................5T 250 V 8.0 A
Typical power and current
90 V, 60 Hz.................................................................... 350 W, 3.9 A, PF 0.99
120 V, 60 Hz.................................................................. 345 W, 2.9 A, PF 0.98
230 V, 50 Hz.................................................................. 342 W, 1.5 A, PF 0.97
264 V, 50 Hz.................................................................. 340 W, 1.3 A, PF 0.97
Measurements made at nominal voltage. Figures are typical, not
maximum, allow for a deviation of +/- 10%.