8
Exterior PixLine™ User Manual
Each time you reach (a) the maximum total length of fixtures in one chain, or (b) 50 m (164 ft.) total length of
the chain, or (c) the PSU output’s maximum power rating
– whichever you reach first –
you must create a
new chain of fixtures that is connected to a new 48 VDC power output.
PROTECTION FROM BURNS AND FIRE
• The Exterior PixLine is cooled by convection. Ensure sufficient ventilation by providing free airflow and
keep a minimum distance of 10 mm (0.4 in.) between the fixture and any surfaces or objects around it.
• Do not operate the Exterior PixLine if the ambient temperature (Ta) around the fixture exceeds 55° C
(131° F).
• Do not modify the Exterior PixLine in any way not described in this manual or install other than genuine
Martin™ parts. Use only accessories approved by Martin™.
PROTECTION FROM INJURY
• Read carefully the chapter “Physical installation” on page 12 and respect the limits and instructions given
in that chapter.
• Ensure that the installation hardware and supporting surface or structure can hold at least 10 times the
weight of all the devices they support.
• Block access below the work area and work from a stable platform whenever installing, servicing or
moving the Exterior PixLine.
• Make sure that all items are securely installed, taking into consideration all possible environmental
conditions including temperature variation and wind. Make sure that it is impossible for items to fall,
causing injury or damage.
• Use grade 8.8 strength fasteners that are suitable for their purpose and the installation environment.
• Fasten 310 mm and 320 mm fixtures to the supporting surface or structure with a minimum of two
fasteners (screws, bolts, etc.) per fixture. Fasten 1270 mm and 1280 mm fixtures to the supporting
surface or structure with a minimum of five fasteners (screws, bolts, etc.) per fixture.
• Either use self-locking nuts or use lockwashers with standard nuts on all bolts.
• Use a torque driver when tightening bolts on mounting profile locks and tighten to a torque of 1 Nm
(0.75 ft.-lbs.).
Type of fixture in
chain
Wattage per fixture
Maximum total length
of fixtures in chain
Maximum total length
of chain (fixtures and
cable)
Exterior PixLine 10,
1280 mm
44 W
10 m
50 m
Exterior PixLine 10,
320 mm
11 W
Exterior PixLine 10,
custom lengths
Allow 36 W per meter
Exterior PixLine 20,
1280 mm
22 W
20 m
50 m
Exterior PixLine 20,
320 mm
5.5 W
Exterior PixLine 20,
custom lengths
Allow 18 W per meter
Exterior PixLine 40,
1280 mm
11 W
40 m
50 m
Exterior PixLine 40,
320 mm
3 W
Exterior PixLine 40,
custom lengths
Allow 9 W per meter
Table 4: Maximum number of Exterior PixLine fixtures per 48 VDC external PSU (provided that PSU
rating in watts is not exceeded).