FAULT FINDING

This fault finding guide assumes that the system has already been
successfully installed and operational. If you have problems at the
installation stage, consult your local Martin agent for advice

No fog output when
using the remote control
to fire the heads

Heads are not ready
Fluid is below min level
Standby button is OFF

No fog output when
using DMX to fire the
heads

Incorrect DMX address
Heads are not ready
No DMX termination

Fluid level is below min

Add more fluid

Fluid out LED is lit on
the service module

Check settings
Allow time with DMX on
Fit 120 ohm resistor

Allow time to reheat
Add fluid
Set standby to ON

SYMPTOM

CAUSE

CURE

One or both heads is
not ready after 15
minutes heating time

Fog disperses too
quickly

Faulty control cable
Blown fuse in head

Check cable
Return to dealer to
repair fault

Wrong grade of fluid
used for the application

Choose a longer lasting
fluid (see front cover)

MAGNUM CLUB SMOKE SYSTEM

USER
GUIDE

8

SYSTEM LAYOUT GUIDELINES

Before beginning the installation, turn to page 4 of the user guide to see the
components that make up the complete system. This is the standard system,
expansions will be dealt with later in the guide.

For detailed instructions on installing each part of the system, refer to the
sections covering each module.

Start the installation by making a sketch of the site in order that cable and
fluid line runs can be optimized. Remember that you must allow for the
height of the heads as well as the distance across the floor space.

The maximum distances and heights can be found in the system
specification at the end of this guide.

When locating the heads, take account of any movement that may occur
when parts of the lighting rig move. This will require a loop of free cable and
pipe to be added into the installation. Avoid this type of installation if
possible.

Avoid locating the heads over public areas

Allow for maintenance access to all parts of the system to make fault finding
and system expansion easier.

Attempt to evaluate the way the effect will disperse in the venue before
permanently fixing the heads into position.

Route the fluid lines from the service module to the heads using smooth
bends to reduce the possibility of the pipe collapsing when forced into a tight
bend.

MAGNUM CLUB SMOKE SYSTEM

INSTALLATION
INSTRUCTIONS

9

Summary of Contents for Magnum Club Smoke System

Page 1: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin dk Magnum Club Smoke System USER GUIDE AND INSTALLATION INSTRUCTIONS VERSION 1 0...

Page 2: ...CLUB SMOKE SYSTEM CONNECTIONS MAGNUM CLUB SMOKE SERVICE MODULE REMOTE IN DMX IN DMX OUT CH 2 CH 1 FLUID CH 2 FLUID CH 1 MAINS IN ON OFF PIN ALLOCATIONS CHANNEL 1 2 1 1 1 2 2 2 3 3 3 READY 0 10 V 0 10...

Page 3: ...ntroller REMOTE CONTROL 16v power supply from service module Standard 0 10V output signal Output level control from 0 to 100 Power On LED Timer cycle LED Timer range Delay time 2sec 18 sec x1 16 sec 2...

Page 4: ...all mountable Service Module Remote control included 0 10 V analogue control is possible DMX decoder as standard 10m fluid lines and control cables Service module can be located up to 50m from Heads 1...

Page 5: ...use with the machine the voltage setting is printed on the serial label Always read the user guide before operating the machine smoke machines need to be operated carefully to avoid risk Do not remov...

Page 6: ...y require 15 minutes to reach operating temperature The LEDs on the rear panels of the heads show the status of the heating cycle When the green LED is on the head is ready to make smoke If the remote...

Page 7: ...he timer functions Switching the heaters in the Heads to standby no power used OUTPUT DELAY TIME RUN TIME FOG STAND BY TIMER VALUE TIMER ON OFF FOG BUTTON STAND BY BUTTON TIMER VALUE BUTTON TIMER ENGA...

Page 8: ...output is automatically reduced The output will remain at this level until the DMX signal is reduced or the fluid is exhausted There is no possibility of damage since the electronic fluid level senso...

Page 9: ...into the push in fitting on the back panel HEAD INSTALLATION CONTROL CABLE FROM SERVICE MODULE POWER CABLE FLUID LINE MAGNUM CLUB SMOKE SYSTEM INSTALLATION INSTRUCTIONS 10 SYSTEM EXPANSION OPTIONS Alt...

Page 10: ...ee the components that make up the complete system This is the standard system expansions will be dealt with later in the guide For detailed instructions on installing each part of the system refer to...