background image

DMX OPERATION

The system may be operated using the industry standard DMX 512 digital
control protocol. This allows the control of the fog system to be easily
integrated with the lighting system in most installations.

DMX may be used without disconnecting the remote control, although the
timer should be switched off to prevent the remote from overriding the DMX
level setting.

The system implements true proportional control of the fog output rather than
the simple switching functions found on other equipment.
See the system specifications for the DMX protocol, and the installation
instructions for the DMX channel settings.

The heaters in the Heads will switch on when the DMX receiver detects valid
data on the link; a channel other than 0 must be set on the address DIP
switches.
To switch off the heaters, simply switch off the DMX transmitter.

When operating from a traditional desk with faders, a 10% dead-band is
implemented at the low end of the output range. Within this range, the output
from the heads is zero.

The system uses a ‘pump ramping’ technique to allow continuous operation.
This means that transmitting DMX 100% will cause the machine to run at full
output until the temperature falls and the output is automatically reduced.
The output will remain at this level until the DMX signal is reduced, or the
fluid is exhausted. There is no possibility of damage, since the electronic
fluid level sensor will shut the system down.

MAGNUM CLUB SMOKE SYSTEM

USER
GUIDE

6

SERVICE MODULE INSTALLATION

The service module is wall mountable via the mounting bracket provided,
although the unit can equally be used floor standing.
To fix the unit to the wall, remove the bracket from the unit and fix to the wall
using 2 x M6 Rawl bolts (or equivalent). Remember to allow enough
clearance above the unit for the cable connections.
If you want to be able to remove the side panels for service purposes, allow
15cm clear space to either side.
Once the bracket is fitted securely to the wall, the unit can be hooked on and
the retaining bolts (2 x M6) fitted.

The functions of the service module connectors are shown on the top panel,
and also in the specifications at the end of this guide.
Connect the control cables to the two heads into the female XLR3
connectors marked Ch1 and Ch2.
The remote control (if required) is connected into the male socket marked
REMOTE. The fluid lines are connected to the two ‘push-in’ connectors
marked Ch1 and Ch2.
DMX connections are made via the two XLR3 connectors marked DMX IN
and DMX OUT.

REMOTE

FLUID 2

FLUID 1

HEAD 1

HEAD 2

POWER

ON/OFF

MAGNUM CLUB SMOKE SYSTEM

INSTALLATION
INSTRUCTIONS

11

Summary of Contents for Magnum Club Smoke System

Page 1: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin dk Magnum Club Smoke System USER GUIDE AND INSTALLATION INSTRUCTIONS VERSION 1 0...

Page 2: ...CLUB SMOKE SYSTEM CONNECTIONS MAGNUM CLUB SMOKE SERVICE MODULE REMOTE IN DMX IN DMX OUT CH 2 CH 1 FLUID CH 2 FLUID CH 1 MAINS IN ON OFF PIN ALLOCATIONS CHANNEL 1 2 1 1 1 2 2 2 3 3 3 READY 0 10 V 0 10...

Page 3: ...ntroller REMOTE CONTROL 16v power supply from service module Standard 0 10V output signal Output level control from 0 to 100 Power On LED Timer cycle LED Timer range Delay time 2sec 18 sec x1 16 sec 2...

Page 4: ...all mountable Service Module Remote control included 0 10 V analogue control is possible DMX decoder as standard 10m fluid lines and control cables Service module can be located up to 50m from Heads 1...

Page 5: ...use with the machine the voltage setting is printed on the serial label Always read the user guide before operating the machine smoke machines need to be operated carefully to avoid risk Do not remov...

Page 6: ...y require 15 minutes to reach operating temperature The LEDs on the rear panels of the heads show the status of the heating cycle When the green LED is on the head is ready to make smoke If the remote...

Page 7: ...he timer functions Switching the heaters in the Heads to standby no power used OUTPUT DELAY TIME RUN TIME FOG STAND BY TIMER VALUE TIMER ON OFF FOG BUTTON STAND BY BUTTON TIMER VALUE BUTTON TIMER ENGA...

Page 8: ...output is automatically reduced The output will remain at this level until the DMX signal is reduced or the fluid is exhausted There is no possibility of damage since the electronic fluid level senso...

Page 9: ...into the push in fitting on the back panel HEAD INSTALLATION CONTROL CABLE FROM SERVICE MODULE POWER CABLE FLUID LINE MAGNUM CLUB SMOKE SYSTEM INSTALLATION INSTRUCTIONS 10 SYSTEM EXPANSION OPTIONS Alt...

Page 10: ...ee the components that make up the complete system This is the standard system expansions will be dealt with later in the guide For detailed instructions on installing each part of the system refer to...