background image

 14

MAC Quantum Profile Safety and Installation Manual

4. Remove each air filter from the head and dispose of it. Do not try to clean or re-use a dirty air filter.

5. Place new air filters in their positions in the head, making sure that there is no gap for air to pass through 

around the edges of the filters.

6. Hook the front end of each filter cover into the head and push the cover into the head until the clip in the 

rear of the cover engages fully. Check that the covers are held securely. 

7. Release the tilt lock before applying power or packing the MAC Quantum Profile in its flightcase.

Servicing optical components

Warning! Disconnect from power and allow to cool for 30 minutes before servicing the components 
in the head.

Optical components have fragile coatings and are exposed to very high temperatures. Use only genuine 
Martin™ parts. Handle and store components with care. Wear cotton gloves while handling them and keep 
them perfectly clean to reduce the risk of heat damage.

Opening the head for service access

To open the head for access to the optical components:

1. Disconnect the fixture from power and allow to cool for 30 minutes.

2. Place the product on a suitable work surface.

3. See Figure 9. Position the head so that the Martin logo on the back of the head is facing the right way up 

and apply the tilt lock (see Figure 1 on page 6).

4. The user may remove the top head cover only. When the Martin™ logo on the back of the head is facing 

the right way up, this cover is on the top of the head. Do not try to remove the other head cover. Loosen 
the cover’s two Torx 25 retaining screws (arrowed) and lift the cover up from the head.

5. If required for easier access, release the head cover’s safety wire from its slot in the head chassis and 

remove the head cover completely.

To close the head, follow the above steps in reverse order. Remember to release the tilt lock before 
applying power or packing the MAC Quantum Profile in its flightcase.

Figure 9: Access to the head for service

Martin logo the right 

way up

Summary of Contents for MAC Quantum Profile

Page 1: ...MAC Quantum Profile SAFETY AND INSTALLATION MANUAL ...

Page 2: ...ect or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document The Martin logo the Martin name the Harman name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Prof...

Page 3: ...sical installation 7 AC power 9 Power input 9 DMX data link 11 Service and maintenance 12 Tilt lock 12 Cleaning 12 Replacing the head air filters 13 Servicing optical components 14 Lubrication 20 Using the fixture 21 Applying power 21 Troubleshooting 22 Specifications 23 ...

Page 4: ... Guide are available for download from the MAC Quantum Profile Product Support page on the Martin website at www martin com Before you install operate or service the MAC Quantum Profile check the Martin website and make sure that you have the latest user documentation for the fixture Document revisions are indicated at the bottom of page 2 Respect all locally applicable laws codes and regulations ...

Page 5: ...R O T E C T I O N F R O M E Y E I N J U R Y Do not look at LEDs with magnifiers telescopes binoculars or similar optical instruments that may concentrate the light output Ensure that persons are not looking at the LEDs when the product lights up suddenly This can happen when power is applied when the product receives a DMX signal or when certain control menu items are selected To minimize the risk...

Page 6: ...0 Aarhus N Denmark Unpacking The MAC Quantum Profile is packaged in either a cardboard box or a flightcase that is designed to protect the product during shipment This Safety and Installation Manual is included with the product The MAC Quantum Profile User Guide containing full details of setting up controlling and monitoring the fixture is available for download from the MAC Quantum Profile Produ...

Page 7: ...type Do not use any type of clamp that does not completely encircle the structure when fastened Warning Position or shade the head so that the front lens will not be exposed to sunlight or any other strong light source from any angle even for a few seconds See Figure 2 The MAC Quantum Profile s lens can focus the sun s rays creating a potential fire hazard and causing damage Important Do not point...

Page 8: ...the truss with the arrow marked FRONT facing towards the area to be illuminated Tighten the rigging clamps 5 See Figure 6 Install a safety cable that is approved as a safety attachment for the weight of the fixture by looping it through the safety attachment point arrowed in the bottom of the base and around a secure anchoring point so that the safety cable will catch the fixture if a primary atta...

Page 9: ...put connector without a cable see Accessories on page 24 Installing a power input connector on a power cable To install a Neutrik PowerCon NAC3FCA input connector on a power cable see illustrations above and right 1 Slide the bushing over the cable 2 Slide the white chuck over cables with a diameter Da of 5 10 mm 0 2 0 4 in or the black chuck over cables with a diameter of 10 15 mm 0 4 0 6 in 3 Pr...

Page 10: ...at the tilt lock is released that the base is held securely and that personal safety will not be put at risk when the fixture lights up and moves then set the power on off switch B to I On Check that the mains power on off switch B is set to O Off before inserting or removing the power input connector at the input socket A otherwise you may cause arcing at connector terminals that can damage them ...

Page 11: ...able and or an amplifier is recommended for longer runs To split the data link into branches use one of the splitter amplifiers available from Martin see under Accessories in the product specifications given at the end of this document Do not overload the link Up to 32 devices may be connected on a serial link Install a DMX termination plug on the last fixture on the link Connecting the data link ...

Page 12: ...trictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lifetimes However optical components are subject to wear and tear over the life of the product resulting in gradual changes in color over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions and environm...

Page 13: ...d press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water 5 Check that the fixture is dry and correctly assembled before reapplying power Replacing the head air filters Free airflow through air filters is important for effective cooling and maximized performance and pro...

Page 14: ...ndling them and keep them perfectly clean to reduce the risk of heat damage Opening the head for service access To open the head for access to the optical components 1 Disconnect the fixture from power and allow to cool for 30 minutes 2 Place the product on a suitable work surface 3 See Figure 9 Position the head so that the Martin logo on the back of the head is facing the right way up and apply ...

Page 15: ...os The MAC Quantum Profile uses specially designed borosilicate gobos with a heavy matted aluminum coating that require particularly careful handling and storage The use of metal gobos in the MAC Quantum Profile is not recommended Do not use gobos with dark coatings on any side as these will absorb heat either directly from the lamp or reflected back from other optical components and will not be d...

Page 16: ...il the gobo you want to replace is easily accessible Avoid disturbing the gobo wheel for the rest of the procedure 3 Rotate the gobo you want to replace until the magnet arrowed points towards a reference position such as the centre of the gobo wheel The magnets in all the goboholders will now point in this direction 4 Holding the edge of the goboholder firmly slide the goboholder out of its clip ...

Page 17: ...Figure 15 You do not need to disconnect the iris unit wireset Lift the iris unit off the multi module and place it beside the module You now have access to the static gobo wheel 4 The static gobo wheel is delicate Do not apply any pressure that might bend it See Figure 16 Holding the wheel with a finger through the open slot to prevent it rotating remove the Torx 30 screw from the Figure 14 Releas...

Page 18: ...ee alignment pins in the alloy retaining disk A The pins must line up with three holes in the gobo wheel B and three holes in the gobo wheel mount C The alignment pins ensure that the gobo wheel can only be mounted in the correct position and facing in the correct direction 6 When service work is finished reinstall the multi module and top head cover as described above Figure 16 Releasing the stat...

Page 19: ...tretch the drivebelt any more than necessary 3 See Figure 19 Push the end of the prism retaining clip down towards the prism until you can release it from its locking slot Lift the clip up and away from the prism 4 Holding the prism by the edge slide it out of the rotating prism unit Figure 18 Removing the prism drivebelt Figure 19 Removing the rotating prism ...

Page 20: ... is finished reinstall the top head cover as described above Color wheel service Color wheel replacement must be carried out by an authorized Martin Service agent with Martin service documentation Lubrication The MAC Quantum Profile does not require lubrication under normal circumstances Moving parts can be checked and a long lasting teflon based grease reapplied by a Martin Service agent if neces...

Page 21: ...ontrol options available using the onboard control and display panel RDM Remote Device Management compatibility Software service functions Applying power Warning Before applying power to the fixture Carefully review the safety information starting on page 4 Check that the installation is safe and secure Check that the base is fastened securely so that the torque reaction when the head is panned wi...

Page 22: ...lace damaged cables Data link not terminated Insert DMX termination plug in data output socket of the last MAC Quantum Profile on the data link Incorrect addressing of fixtures Check fixture address and protocol settings One of the fixtures is defective and is disturbing data transmission on the link Unplug the XLR in and out connectors and connect them directly together to bypass one fixture at a...

Page 23: ...el and DMX Control and Programming Control system DMX RDM Implemented Control resolution 8 bit with 16 bit control of dimming gobo indexing zoom focus pan and tilt DMX channels 19 27 Setting and addressing Control panel with backlit graphic display DMX compliance USITT DMX512 A RDM compliance ANSI ESTA E1 20 Transceiver RS 485 Fixture software update Direct with USB memory stick or over DMX link w...

Page 24: ... EN 55103 2 EN 61000 3 2 EN 61000 3 3 EN 61547 US safety pending UL 1573 US EMC FCC Part 15 Class A Canadian safety pending CSA C22 2 No E598 2 17 CSA E60598 1 Canadian EMC ICES 003 Class A Australia NZ C TICK N4241 Included Items Safety and Installation Manual Two omega brackets with quarter turn fasteners Accessories 3 m power cable 12 AWG SJT with PowerCon NAC3FCA power input connector P N 1154...

Page 25: ...A201370746 DKPA201470172 DKPA201470409 EP13763923 3 JP2013 505332 JP2013 505333 JP2013 505334 RU2012144005 RU2012144006 RU2012144007 US13 991 435 US14 342 105 US14 362 457 and or one or more of these designs CN201430042777 5 CN201430200783 9 CNZL201430042909 4 CNZL201430043080 X EU002418756 EU002422204 EU002489856 US29 484171 US29 484173 US29 484179 US29 494964 and or one or more other intellectua...

Page 26: ......

Page 27: ......

Page 28: ...www martin com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...

Reviews: