MAC 700 Wash Spill Limiter Kit Installation Guide – Page 3 of 13
• Drill with 3.2 mm (1/8 inch) and 3.8 mm HSS drill bits.
To help you avoid dropping screws into the fixture, we recommend that you magnetize tools. Use of a
powered screwdriver with correctly set torque will also save you time.
Installation procedure
To install the MAC 700 Wash Spill Limiter Kit components in a standard MAC 700 Wash fixture:
1.
Disconnect the fixture from power, allow to cool, and place on a workbench. Take precautions
against ESD (electro-static discharge).
2.
See Figure 1. Release the head cover retaining screws (arrowed) and remove the head covers.
3.
Apply the tilt lock. See Figure 2. Release the module locks on both sides of the effects module and
lift the module out of the head.
Figure 1
A
B
C
Figure 2