background image

      DMX Protocol                                                                             

22      

                                                                                   

a p p e n d i x   a  

D M X   P R O T O C O L

DMX1

DMX2

DMX3

DMX4

Value

Percent

Function

Start code = 0

1

Note: To override (DMX) Reset or Lamp 
Off = OFF, set all 3 CMY channels to a 
value from 230 to 232.

0 - 19

20 - 49
50 - 72
73 - 79
80 - 99

100 - 119
120 - 127
128 - 147
148 - 167
168 - 187
188 - 190
191 - 193
194 - 196
197 - 199
200 - 202
203 - 207
208 - 217
218 - 227
228 - 237
238 - 247
248 - 255

0 - 7

8 - 19

20 - 28
29 - 31
31 - 39
39 - 47
47 - 50
50 - 58
58 - 65
66 - 73
74 - 75
75 - 76
76 - 77
77 - 78
78 - 79
80 - 81
82 - 85
85 - 89
89 - 93
93 - 97

97 - 100

Shutter, Strobe, Reset, Lamp On/Off

Shutter closed
Open
Strobe, fast to slow
Open
Opening pulse, fast to slow
Closing pulse, fast to slow
Open
Random strobe, fast
Random strobe, medium
Random strobe, slow
Open
Random opening pulse, fast
Random opening pulse, slow
Random closing pulse, fast
Random closing pulse, slow
Open
Reset, see note
Open
Lamp on 
Open
Lamp off: time > 5 seconds, see note

2

0 - 255

0 - 100

Dimmer
Closed to open

3

0 - 255

0 - 100

Cyan
White to full cyan

4

0 - 255

0 - 100

Magenta
White to full magenta

5

0 - 255

0 - 100

Yellow
White to full yellow

6

0 - 179

0

26
52
78

104
130
156

180 - 183
184 - 187
188 - 191
192 - 195
196 - 199
200 - 203
204 - 207

208 - 226
227 - 245

246 - 248
249 - 251
252 - 255

0 - 70

0

10
20
31
41
51
61

71 - 72
72 - 73
74 - 75
75 - 76
77 - 78
78 - 80
80 - 81

82 - 88
89 - 96

96 - 97
98 - 98

99 - 100 

Color 
Continuous scroll
White
CTC 5500-2900K
Pink 312
UV
Red 308
Green 206
Blue 108

Stepped scroll
Blue 108
Green 206
Red 308
UV
Pink 312
CTC 5500-2900K
White

Continuous rotation
CW, fast to slow
CCW, slow to fast

Random CMY color
Fast
Medium
Slow

Summary of Contents for MAC 300

Page 1: ...MAC 300 user manual...

Page 2: ...Service 17 Troubleshooting 21 DMX Protocol 22 Error Messages 24 PCB Layout 25 Accessories 26 Specifications 27 1999 2000 Martin Professional A S Denmark All rights reserved No part of this manual may...

Page 3: ...ified technician To pro te ct yo urs e l f a nd ot he rs f rom UV rad ia t io n a nd l a mp ex pl os i on Never operate the fixture with missing or damaged lenses and or covers When replacing the lamp...

Page 4: ...ing bracket 1 5 meter 3 pin shielded XLR control cable 1 3 meter 3 wire IEC power cable 1 user manual The packing material is carefully designed to protect the fixture during shipment always use it or...

Page 5: ...by its ceramic base do not touch the glass align the small pin with the small hole and insert the lamp squarely into the socket Make sure that the 4 small projec tions on the base contact the face of...

Page 6: ...ge setting For example use the 120 V setting if your voltage is 110 V 3 Replace the cover W ir i n g t h e m ai n s l e ad 1 Install a grounding type cord cap on the mains lead Connect the yellow gree...

Page 7: ...ontroller s data output then connect a regular data cable to the swapper cable Alternatively reconfig ure the XLR pin out as described on page 19 2 If convenient you may split the link into branches u...

Page 8: ...fasten a safety cable to the reinforced attachment point in the base The 1 4 turn fasteners are locked only when turned fully clockwise 1 Verify that the clamps are in good condition and can bear at...

Page 9: ...e and any error messages are displayed after the MAC 300 resets To enter the menu press MENU Use the and keys to move within the menu To select a function or submenu press Enter To escape press MENU S...

Page 10: ...rol Pan inverse PATI PINV ON Reverse DMX pan control right left OFF Normal pan control left right Tilt inverse PATI TINV ON Reverse DMX tilt control down up OFF Normal tilt control up down Pan tilt sp...

Page 11: ...option selected above The default setting is OFF To turn it on navigate to the PSET sub menu select AUTO press Enter select ON and press Enter 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8...

Page 12: ...tin address at the top of the menu depends on the protocol selected To s e t a D M X a ddr e s s To s e t a M a r ti n a ddr e s s The MAC 300 uses 2 Martin RS 485 channels Press To Menu As required D...

Page 13: ...the CPU software CPU feedback cir cuit software FEBA and display module software dISP U t il i t i e s Up lo a d mo de The software upload mode is engaged automatically by the MPBB1 Uploader Engage up...

Page 14: ...s PATI Calibrate effects CAL He a d e ffe c ts ad ju s tme n t The head submenu AdJ HEAd provides manual control when making mechanical adjustments which must be performed by a qualified technician It...

Page 15: ...so provides a special blackout speed and overrides of the shortcut and pan tilt speed personality set tings 8 bi t ve rsu s 1 6 b it p an t il t r e so lu ti on With 8 bit pan tilt resolution pan and...

Page 16: ...ease see Changing color filters on page 18 and additional colors are available from Martin please see Accessories on page 26 The wheel can be scrolled continuously allowing for split color effects or...

Page 17: ...Disconnect the fixture from AC power and allow it to cool before removing any cover Clean ing O pt ic a l c om po ne nt s Use care when cleaning optical components The surface on dichroic filters is...

Page 18: ...rd LEDs does not light one of these fuses may be blown 1 Disconnect the fixture from AC power Remove the 2 Philips screws from the plastic cover on the arm opposite the side with the visible motor and...

Page 19: ...uted 4 If the light is brighter around the edge than it is in the center or if light output is low the lamp is too far back in the reflector Pull the reflector in by turning the screws clockwise 1 4 t...

Page 20: ...ngle diffusion lens is available for the MAC 300 The diffuser gives the MAC 300 a 59 beam angle If the frost filter is fully applied the beam angle is 67 Photometric data for this option is available...

Page 21: ...t addressing of the fix tures Check address and protocol settings One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is reg...

Page 22: ...om strobe medium Random strobe slow Open Random opening pulse fast Random opening pulse slow Random closing pulse fast Random closing pulse slow Open Reset see note Open Lamp on Open Lamp off time 5 s...

Page 23: ...king PTSP FAST override SLOW Blackout while moving 11 13 0 2 3 245 246 248 249 251 252 255 0 2 3 245 246 248 249 251 252 255 0 2 3 251 252 255 0 1 1 96 96 97 98 98 99 100 0 1 1 96 96 97 98 98 99 100 0...

Page 24: ...an occur if the lamp relay is stuck The fixture may be operated but remote lamp on off may be effected Contact service technician Hot Hot lamp you attempt to strike the lamp within 8 minutes after hav...

Page 25: ...Layout a p p e n d i x c P CB L AYOU T Hard boot jumper XLR jumper Fan Switch Color wheel Cyan Magenta Yellow Dimmer Frost Pan Tilt Hall sensor Link Light sensor AC input Fan Opto1 Opto2 Display Brow...

Page 26: ...3 Red 308 46404316 Blue 107 46404325 Red 309 46404341 Blue 108 46404320 Yellow 601 46404317 Blue 111 46404304 Yellow 602 46404342 Cyan 401 46404305 Yellow 603 46404318 CTC 5500 2900K 46404306 Yellow 6...

Page 27: ...a m mi ng Data pin out pin 1 shield pin 2 cold pin 3 hot Receiver Opto isolated RS 485 Protocols USITT DMX 512 1990 Martin RS 485 DMX Channels 9 13 Co nne c ti on s AC input 3 prong IEC male socket Da...

Page 28: ...ff 246 248 F fast PTSP or shortcuts on 249 251 blackout speed 252 255 variable speed points to fast 25 50 75 100 125 150 175 200 225 250 L I G H T P T S P E E D TS TF TS TF TS TF OPEN OPEN OPEN OPEN M...

Page 29: ......

Page 30: ...Unit C6 Hastingwood Trading Estate 35 Harbet Road London N18 3HU Phone 020 8803 7400 email office gradav co uk FAX 020 8803 5060 Web www gradav co uk...

Reviews: