8
MAC 101 user manual
AC power
Warning! Read “Safety Information” starting on page 3 before connecting the MAC 101 to AC mains
power.
Warning! For protection from electric shock, the MAC 101 must be grounded (earthed). The power
distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault)
protection.
Warning! The MAC 101 does not have a power on/off switch. Socket outlets or external power
switches used to supply the MAC 101 with power must be located near the fixture and easily
accessible so that the fixtures can easily be disconnected from power.
Warning! Do not insert or remove live Neutrik PowerCon connectors to apply or cut power, as this
may cause arcing at the terminals that will damage the connectors.
Important! Do not use an external dimming system to supply power to the MAC 101, as this may
cause damage to the fixture that is not covered by the product warranty.
The MAC 101 can be hard-wired to a building electrical installation if you want to install it permanently, or a
power plug that is suitable for the local power outlets can be installed on the power cable.
Power voltage
Warning! Check that the voltage range specified on the fixture’s serial number label
matches the local AC mains power voltage before applying power to the fixture.
MAC 101 fixtures accept AC mains power at 100-240 V nominal, 50/60 Hz. Do not apply AC mains power to
the fixture at any other voltage than that specified on the fixture’s serial number label.
Power cables and power plug
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG)
minimum and a total cable diameter of 5 - 15 mm (0.2 - 0.6 in.). Cables must be extra hard usage type (ST
or equivalent) and heat-resistant to 90° C (194° F) minimum.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A
minimum. Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes
and some possible pin identification schemes; if pins are not clearly identified, or if you have any doubts
about proper installation, consult a qualified electrician.
Wire Color
(EU models)
Wire Color
(US models)
Conductor
Symbol
Screw (US)
brown
black
live
L
yellow or brass
blue
white
neutral
N
silver
yellow/green
green
ground (earth)
or
green
Table 1: Wire color-coding and power connections