Installation and setting up
11
Installation and setting up
DANGER! DO NOT operate the haze machine until you have read and observed
all the precautions listed under “Safety information” on page 5.
Locatio n
The Jem Hazer Pro™ is designed to be located on the floor or may be
suspended using the optional flying kit. If suspending the machine, the handles
are removed and four eyebolts provided in the flying kit are fitted in their place.
The machine can operate in any orientation from 30 degrees upwards to 30
degrees downwards. Steeper tilting may cause fluid leakage.
If the machine is to be suspended, ensure the mounting surface can support the
weight of the machine. Do not suspend the machine over areas where people
will be underneath. Use only the correct Martin flying kit to suspend the machine.
Ensure that there is at least 100mm clearance all round the machine and at least
60cm in front of the haze output.
AC power
Before using the machine, ensure that a grounding-type (earthed) power plug
that fits the local power outlets is installed on the Neutrik Powercon cable
provided.
DANGER! Make sure the power plug is correctly rated:
• For EU (230V) use fit a plug rated 6 amp minimum
• For US (120V) use fit a plug rated 10 amp minimum
When installing the plug, follow the plug manufacturer’s instructions and connect
pins as follows:
Yellow and green wire to ground (earth), blue wire to neutral and brown wire to
live.
The table below shows some common pin identification schemes.
wire function
marking
screw
colour
brown live
“L”
yellow
or
brass
blue neutral
“N” silver
green/yellow earth
green