Installation
9
I
NSTALLATION
4
The FiberSource QFX 150 can be fastened directly through the 4 rubber washers in
the mounting flanges, or hung with 2 rigging clamps (not included) fastened
through the 13 mm holes.
I N S T A L L A T I O N R E Q U I R E M E N T S
For optimum performance and ease of service, install the fixture such that
• The long axis is horizontal as
shown in A to right. This
positions the lamp electrodes
for maximum lamp life. Do not
install as shown in B.
• The minimum clearance around
the fans and air vents at both
ends is 10 cm (4 in.) and
circulation is adequate keep the
air around the fixture at 40° C
(104° F) or below.
• The DIP-switch is accessible and there is room to insert cables.
• The lamp access panel can be removed.
• All safety requirements are met.
To i ns ta l l t h e F i b e r So ur ce QFX 15 0
Warning!
Always use a secure means of secondary attachment when
hanging the fixture with clamps.
1 Verify that the fasteners or clamps can bear 10 times the fixture’s weight. Verify
that the structure can support 10 times the weight of all installed fixtures,
clamps, cables, auxiliary equipment, etc.
2 Block access below the work area.
3 If fastening directly, place a metal washer over each rubber washer. The metal
washer must be as wide as the rubber washer, or wider, to insure a secure hold.
Fasten with 4 suitable fasteners 4 - 5 mm (5/32 - 3/16 in.) in diameter.
35000079B.fm Page 9 Thursday, December 9, 1999 11:47 AM