Service manual
9 of 18
Exterior Inground 400 LED - Revision B, 08-18-2017
Replacing the housing
1.
Follow the procedure in “Uninstalling the fixture”
on page 7 and “Removing the insert module”
on page 7.
2. Store the insert module in a suitable and safe
place while you remove the old fixture housing
and mount the new housing inside the sleeve.
3.
Remove the old housing from the sleeve and
uninstall the cable from the connection box which
is placed below the housing.
4.
Remove the mains power and DMX cables when
you remove the old housing.
NOTE! The old cables are molded to the housing
and must not be reused. New cables are included
in the new housing.
5.
Reinstall the insert module.
6.
Connect the cables from the new housing into
the connection box in the sleeve and fasten the
housing to the sleeve.
7. Before you close the fixture, follow the instructions
in “Closing the fixture” on page 15.