Martin Engineering M4082-01/22
19
CleanScrape
®
Small Cleaner
Figure 13. Measure Cleaner Angle
Tensioning
cleaner
1. Measure angle of cleaner.
2. Determine tension required according to tensioning chart.
3. Tighten tensioners. Install and tighten jam nut against tensioning nut on
each tensioner.
4. Make sure outer two elements on each side are away from belt.
Table II. CleanScrape
®
Small Cleaner Tensioning Chart
*Lower rope should have 10% to 15% less force than upper rope.
Conveyor Center Line
X°
CSP Size
Belt Width
Upper Rope
Force Required
Lower Rope
Force Required*
mm
(in.)
Small
500
18
1.00 kN
0.85 kN
501–650
24
1.20 kN
1.00 kN
651–800
30
1.40 kN
1.20 kN
801–900
36
1.50 kN
1.30 kN
901–1000
42
1.60 kN
1.40 kN
Installation