4. Working from a stable platform, fasten
the fixture to the structure or surface. If
mounting on a surface, use a grade
8.8 (minimum) M12 bolt or screwbolt,
passing it through the hole in the
fixture’s mounting bracket (see
illustration).
5. Install a safety cable that can
hold at least 10 times the
weight of the fixture, passing it
through the fixture’s handle
(see illustration) and around
the mounting structure or
through the eyebolt in the
mounting surface.
Warning!
Do not simply pass the
safety cable through the
fixture’s mounting bracket,
as this will leave the fixture
unsecured.
6. Loosen the swivel locks, tilt the fixture to the desired angle, and
retighten.
7. Check that the fixture is held securely.
8. Check that the fixture is at least 0.3 meters (12 in.) from the surface to
be illuminated and at least 0.1 meters (4 in.) from any combustible
materials.
9. Check that the clearance around the air vents is at least 0.1 meters (4
in.), and that airflow around the vents is free and unobstructed.
D A T A C O N N E C T I O N
You need to create a serial data link to:
• Control fixtures via a DMX control device.
• Operate two or more Ego X Series fixtures of the same type in
master/slave stand-alone mode, where all fixtures run a synchronized
light show without a separate DMX control device.