background image

Compact 

Scarecrow 

-

 technical help

 

Trouble Shooting

 

 

If, after following the set

-

up instructions, you are having difficulty getting your Compact to operate 

follow the step by step trouble

-

shooting guide below:

 

No LED’s illuminated on unit?

 

Ensure the power supply is wired correctly or, if using battery power, that the battery has sufficient 

charge and is connected correctly as per the instructions on page 7.

 

 

No Sound, but LEDs illuminated?

 

Ensure Switch 9 in the 

Mode Switch Block 

is set to ON

 

Check the Volume Control (D) is not fully anti

-

clockwise.

 

Check that a slight buzzing sound can be heard from the speakers.

 

 

 

Red and Yellow LED Blinking.

 

This indicates the unit has gone into night mode. To resolve this:

 

With the power connected, turn the Ambient Light Sensor Control (C) fully clockwise. The yellow 

LED should now be on constantly.

 

Disconnect the power from the unit for 20

-

30 seconds

 

Re

-

connect the power and the red LED should now be off.

 

 

Red, Yellow and Green LED Blinking once every 3 seconds.

 

This indicates that the battery level is below 10v. To protect the battery, the unit will not operate 

below 10v. Normal operation will resume when the battery voltage exceeds 11v. 

 

 

Technical Assistance and Service Requirements

 

For technical assistance with installing or operating your Compact  unit,  contact  Martin Lishman 

Ltd as follows:

 

Tel: 01778 426600; E

-

mail: [email protected]

 

We should be able to answer most questions or put you in touch with an experienced user. If we 

cannot help we will refer you to the manufacturers Scarecrow Bio

-

Acoustics Ltd.

 

 

 

 

 

Warranty:

 

Compact Scarecrow products are guaranteed for 12 months from the date of purchase against any defect or malfunction caused by 

faulty parts or workmanship. To claim under warranty, the complete unit or part should be returned, at the claimant’s expense, to Martin Lishman 

Ltd or to Scarecrow Bio

-

Acoustics Ltd (as advised) with a written explanation of the problem. Should there prove to be a defect  or malfunction 

caused by faulty parts or workmanship, it will be repaired or replaced and returned to the claimant without charge. If a warranty claim is rejected, 

the cost of replacement or repair will be notified to the claimant before any work is carried out.

 

Any warranty claim will automatically be invalidated if the unit has been modified or internally tampered with in any way. The manufacturers will not 

cover under warranty damage or faults occurring to the unit which have been caused by inappropriate use or by use not in accordance with the 

installation and operating instructions for the unit.

 

Under no circumstances will Martin Lishman Ltd re

-

imburse any costs associated with a warranty claim if these costs have been incurred without 

agreement in advance.  Under the terms of warranty for the unit under no circumstances will liability exceed the cost of replacement or repair.

 

Whilst the unique efficiency of Scarecrow bio

-

acoustic products is long established, Scarecrow Bio

-

Acoustic Systems Ltd stress that they can only 

work effectively as part of an overall and planned programme of bird control. Without limitation, the manufacturers Scarecrow Bio

-

Acoustics Ltd and 

Martin Lishman Ltd will not be liable for any consequential or indirect loss suffered by purchasers or users of the unit, whether this loss arises from 

correct or incorrect use, defect or malfunction caused by faulty parts or workmanship, poor equipment maintenance, failure of due diligence, lack of 

prior consultation or in any other way. Non

-

exhaustive illustrations of consequential or indirect loss are loss of profits, loss of contracts and damage 

to property.

 

 

All rights reserved: no part of this publication may be quoted or reproduced, stored in a retrieval system or transmitted in any form including Internet or 

by  any  other  means  electronic,  mechanical,  by  photocopying  or  recording  in  any  way  but without  limitation  unless  the  prior  written  consent  of  the 

copyright holders is obtained and which shall not be unreasonably withheld.

 

 

© 

Scarecrow Bio

-

Acoustic Systems Ltd and Martin Lishman Ltd June 2013

 

13

 

Summary of Contents for Scarecrow COMPACT 200

Page 1: ...ted by Martin Lishman Tel 01778 426600 www martinlishman com Compact 200 Master Unit Compact 360 Master Slave Unit Compact Solar Unit COMPACT Scarecrow Instruction Manual for Agricultural and Horticultural use ...

Page 2: ...Scarecrow Typical Uses Jackdaws in peas Starlings on silage Gulls on rubbish Cormorants on fishing lakes Rooks in fruit orchards Pigeons in cereals brassicas fruit Crows in cereals on golf greens Grazing geese ...

Page 3: ...d mounting the Compact 360 Master and Slave Units 6 Assembling and mounting the Compact Solar Unit 6 Power Supply and Electrical Connections Master Unit Battery power connection 7 Mains power connection 7 Connecting the Master to the Slave 7 Connecting the Solar Unit 8 Control Panel Settings Test mode 9 Setting the volume level 9 Setting the ambient light sensor 10 Setting the bird distress calls ...

Page 4: ...ors can affect coverage Assess each situation and make allowances Hills and Valleys Wind speed and direction Trees and hedges Walls and buildings Re positioning Keep it Weekly Give Compact a chance to do its job don t move it too frequently 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Please read the instructions for the unit carefully to ensure you are creat...

Page 5: ... arable farm use 1 Herring Gull OFF 2 Black Headed Gull OFF 3 Starling OFF 4 Rook ON 5 Crow ON 6 Pigeon Jackdaw ON 7 Normal playback sequence OFF 8 Light sensor over ride OFF 9 Auto timer ON 10 Test mode OFF Normal LED lights Red ON Auto timer on FLASHING At night ambient light sensor activated Green ON Bird call playing FLASHING 60 second pause between calls Yellow ON Daylight FLASHING 60 minute ...

Page 6: ...e Power On aperture are fitted with removable plastic covers Also included Master Unit see Compact 200 above Instruction Manual and Unit Test Certificate Cover from Solar Input socket F Compact Master and Slave Accessories some of the following items may also have been supplied U Clamps mates with rear brackets to provide pole fixing for Master Unit Power Supply Unit 240v ac 15v dc mains power sup...

Page 7: ...nit Underside view Solar Panel plus H Bracket with connecting lead and plug attached Also included Instruction Manual and Unit Test Certificate Booster Cable 2 pin plug do not use if 4 pin plug 4 Solar Pole Base Kit 2m pole and mountings with 1m square base to position Compact in free standing location requires 4x450mm square paving slabs or similar for installation stability supplied with 2x M10 ...

Page 8: ...species react with varied urgency However and wherever it is located the Compact must be properly secured so that wind and animals cannot dislodge it Fitting accessories are available to assist this see below The Compact outer casing has been specifically designed with a sloping top to ensure that any rain water runs off the top of the unit When assembling the unit please ensure that the control p...

Page 9: ... the remaining pole in the clamps and tighten the clamp bolts and nuts The end result should be as per the picture below 3 Locate the Master and Slave Units around the support pole as per the instructions at the top of this page 4 Attach the solar boss to the top of the mounting pole using the M10 x 60 bolt and the M10 nyloc nut supplied then attach the solar panel as per the picture below and sec...

Page 10: ...anti clockwise as shown in the photos below b Slacken off the gland at the base of the socket and slide the socket housing back on the cable until the cable connectors are accessible c If battery power is not required disconnect and remove the battery cable d Feed the bare ends of the Power Supply Unit lead through the socket housing from the narrow end e Look for the very small numbers 1 4 at the...

Page 11: ...lead to the Power Input Plug marked A on the underside of the both units 2 Connect the Solar Panel Lead which comes with one end already connected to the solar panel to the Solar Input Socket F on the underside of the Solar Slave Unit 3 Using the Control Adjustment Tool insert this into the POWER ON aperture on the underside of the Solar Slave Unit and press gently until you feel a click This will...

Page 12: ...lume correctly is an absolutely critical factor in ensuring successful results with the unit Any bird species will assume the bird distress calls to be false if they appear to be too loud or unnatural The sound level needs to be such that the birds are aroused and agitated just enough to cause them to disperse Background noise and the lie of the land can both affect how the sound travels so some t...

Page 13: ...f this pause is to prevent intermittent light pollution such as car headlights from interfering with dawn light detection Note The Compact will not start broadcasting if powered up during darkness since the Ambient Light Sensor will activate and prevent operation until dawn To adjust the Ambient Light Sensor It is not normally necessary to adjust the setting of the Ambient Light Sensor but this ca...

Page 14: ...distress calls can be loaded onto the Compact at any one time However for a small charge any of the standard calls can be exchanged for another from an extensive library of calls A possible requirement might be Canada Geese and there are several options for deterring grazing by this group of species or House Sparrows to keep them out of grain stores The Mute Swan as its name suggests does not have...

Page 15: ...ction of the prevailing wind and the wind speed The use of the Slave unit giving a complete 360 coverage would obviously add to the effect of the 200 Master unit and give the most effective results In our own trials on a calm day in a shallow valley rooks and crows up to 2 miles away lifted and were disturbed In the same valley a 200 acre block of rape was kept clear of pigeons from one Compact lo...

Page 16: ...uld there prove to be a defect or malfunction caused by faulty parts or workmanship it will be repaired or replaced and returned to the claimant without charge If a warranty claim is rejected the cost of replacement or repair will be notified to the claimant before any work is carried out Any warranty claim will automatically be invalidated if the unit has been modified or internally tampered with...