background image

MT110L User’s Manual V1.0

 

20

 

 

Chapter 3 Interface 

BT HID 

Getting Connected 

1.  Press the function button on the top to power up the scanner. 
2.  Scan “

Disconnect

”, the scanner will emit two beeps. Alternatively, press and hold the function 

button for 5 seconds until the scanner emits two beeps 

 

Disconnect 

 

3.  Scan “

BT HID

”, the scanner will emit two beeps. 

 

BT HID 

 

4.  Select “Wireless Scanner” from discovered device list. 
5.  If Bluetooth application prompts you to enter a pincode, please follow the steps in 

Pincode 

Setup

 section. 

6.  The scanner will emit two beeps as indication that the Bluetooth connection has established 

successfully. 

7.  While conneted with the scanner as physical keyboard, the touch keyboard on iOS/Android 

device might disappear. To resolve this issue please do the following: 

(1) For iOS device, simply press the function button on the top once. 

(2) For Android device, go to “Settings” > “Language & Input”, tap on “Default keyboard” and 

turn off “Physical keyboard” or turn on “On-screen keyboard”. 

 

 

 

 

 

 

 

 

Summary of Contents for MT110L

Page 1: ...MT110L User s Manual V1 0 MT110L SBR Laser Scanner User s Manual Version 1 0 DATE 2022 07 28 ...

Page 2: ... FORMAT 14 HT CR ESC Converts to TAB ENTER ESCAPE 14 Function Code Conversion 14 Numeric Key 15 Capslock Mode 15 Keyboard Layout 16 Intercharacter Delay 18 Interblock Delay 18 BCC Binary Check Character 19 IMAGING SETTINGS 19 Inverse Barcode 19 CHAPTER 3 INTERFACE 20 BT HID 20 Getting Connected 20 Pincode Setup 21 BT SPP 22 Getting Connected 22 Set SPP Pincode 23 GENERAL BLUETOOTH SETTINGS 24 Powe...

Page 3: ...TOGGLE MODE 34 FLASH MODE 34 CONTINUOUS MODE 35 CONTINUOUS AUTO OFF MODE 35 Flash Continuous Mode Trigger Control 35 Trigger Toggle Mode LED Auto Off Control 36 Trigger Toggle Flash Continuous Auto Off Mode LED Auto Off Timeout 36 Flash Continuous Continuous Auto Off Mode Identical Read Interval 37 ACCURACY ADJUSTMENT 37 CHAPTER 5 DATA FORMAT 38 CODE ID 38 SET ID 38 DATA LENGTH 40 PREAMBLE 41 POST...

Page 4: ...d On Supplement 49 EAN 13 50 Enable Disable EAN 13 50 Lead Digit 50 Check Digit 50 Add On Supplement 50 ISBN 51 ISSN 52 ISMN 52 CODE 128 53 Enable Disable Code 128 53 Code 128 Min Max Length 53 GS1 128 UCC EAN 128 54 Enable Disable GS1 128 54 GS1 128 AIM ID 54 FUNC 1 Character 54 GS1 128 Min Max Length 55 CODE 39 56 Enable Disable Code 39 56 Verification 56 Start Stop 56 Full ASCII Code39 57 Code3...

Page 5: ...ast Digit Suppressed 67 Interleaved 2 of 5 Min Max Length 68 IATA STANDARD 2 OF 5 69 Enable Disable IATA 69 Verification 69 IATA Min Max Length 69 MATRIX 2 OF 5 70 Enable Disable Matrix 2 of 5 70 Verification 70 Matrix 2 of 5 Min Max Length 71 INDUSTRIAL 2 OF 5 72 Enable Disable Industrial 2 of 5 72 Verification 72 Industrial 2 of 5 Min Max Length 72 CHINA POSTAL CODE TOSHIBA CODE 74 Enable Disabl...

Page 6: ... 79 Check Digit 79 GS1 DATABAR EXPANDED RSS EXPANDED 79 Enable Disable GS1 DataBar Expanded 79 Enable Disable GS1 DataBar Expanded Stacked 80 GS1 DataBar Expanded Min Max Length 80 CHAPTER 7 APPENDIX 81 APPENDIX NUMBERS 81 APPENDIX UPPER CASE ALPHABETS 82 APPENDIX LOWER CASE ALPHABETS 84 APPENDIX CONTROL CODES 86 APPENDIX SYMBOLS 88 APPENDIX FUNCTION KEYS 91 APPENDIX NAVIGATION KEYS 92 APPENDIX MO...

Page 7: ...obile operator Specifications Optic Performance Light Source 650nm visible red Laser Visible white LED Sensor Linear Image Sensor Scan Rate 380 Scans Sec Resolution 4mil 0 1mm Scan Angle 41 Pitch Angle 30 Skew Angle 40 Roll Angle 20 Print Contrast Ratio 30 Width of Field 140mm 13Mil Code39 Memory 2MB 20 000 barcodes Typical D O F 4 Mil Code 39 34 84mm LED Indicator Function Button Toggle iOS keybo...

Page 8: ...0mAh Li Polymer Battery Number of Scan per full charge 5400 scans 1 scan 5 secs Bluetooth connected Connectivity Radio Bluetooth 5 0 dual mode Class 2 Range 66 ft 20m line of sight Interface Profile BT HID BT SPP USB HID USB VCP Memory User Environment Operating Temperature 10 50 C Storage Temperature 20 60 C Humidity 0 95 RH Non condensing Drop Durability 1 5M Ambient Light 50 000 Lux Sunlight 1D...

Page 9: ...2801 ISO 11737 1 2 Beeper Indication Beeper Status Single beep Good read Single short beep The scanner reads a Code39 ASCII during multi step configuration Two beeps Wireless connection The scanner successfully reads a configuration barcode Three beeps Wireless disconnection Three short beeps The scanner reads a barcode while disconnected The scanner reads an unexpected barcode during multi step c...

Page 10: ...MT110L User s Manual V1 0 10 LED Indication LED Status Off Power off Standby Connected Flashing green Disconnected Discoverable One green flash Good read Flashing red Low power Solid red Charging ...

Page 11: ...gs by scanning configuration barcodes in this manual Enable Barcode Configurability Disable Barcode Configurability Factory Default Scanning below configuration barcode will reset all parameters to factory default settings the ones with asterisk mark Factory Default Check Version To check firmware version please scan below configuration barcode Check Version ...

Page 12: ... of the settings does not affect the scanner s Laser safety standard Class 1 which is non hazardous to human eyes Dim Bright Illumination Scan below barcodes to determine illumination behavior according to your preference Laser Always On LED Auto Adaptive Laser Always On LED Off Laser Off LED Always On Laser Always On LED Always On ...

Page 13: ...MT110L User s Manual V1 0 13 Good Read Indicator Beep Tone Off Beep Low 2 0KHz Beep Medium 2 7KHz Beep High 4 0KHz Beep Mode Normal Warning Beep Only Mute Vibrator Off On ...

Page 14: ...d ESC A is transmitted as 0x09 0x0D and 0x1B respectively 2 When enabled HT I CR M and ESC A is transmitted as TAB ENTER and ESCAPE on keyboard respectively Function Code Conversion Off On Note Once disabled the scanner will output the original encoded data of the barcodes in Appendix Function Navigation Modifier Keys ...

Page 15: ...he keys on the numeric keypad 2 If you select NUMERIC KEY the Num Lock status of the physical keyboard should be ON Capslock Mode Capslock Off Capslock On Capslock Free Note When barcode scanner is set to Capslock Free mode no matter keyboard Capslock LED indicator is ON or OFF output will be always the same as the Original barcode In other words what you see is what output is ...

Page 16: ...MT110L User s Manual V1 0 16 Keyboard Layout English US English UK Danish Spanish Hungarian QWERTZ Hungarian QWERTY Canadian French Dutch Italian French German Swiss German ...

Page 17: ...MT110L User s Manual V1 0 17 Swiss French Swedish Czech QWERTZ Czech QWERTY Norwegian Belgian Portuguese Slovak Brazilian QWERTY Canadian Traditional Japanese Alt Code ...

Page 18: ...er Delay to 8ms Step1 Scan Set Intercharacter Delay Step2 Scan 0 0 8 in Appendix Numbers Step3 Scan Set Intercharacter Delay Interblock Delay The configurable range is from 0 to 2550ms The larger the number the longer the delay Set Interblock Delay Default 0ms Example Set Interblock Delay to 20ms Step1 Scan Set Interblock Delay Step2 Scan 0 0 2 in Appendix Numbers Step3 Scan Set Interblock Delay ...

Page 19: ...xample The barcode data is TEST with terminator CR LF 1 BT SPP USB VCP Data Format T E S T CR LF BCC BCC 54h 45h 53h 54h 0Dh 0Ah 11h 2 BT HID USB HID Data Format T E S T Enter BCC BCC 54h 45h 53h 54h E7h F1h However since control character cannot be displayed in Bluetooth HID BCC will be converted into 2 bytes of characters As a result the data will be TEST Enter F 1 Imaging Settings Inverse Barco...

Page 20: ...ed device list 5 If Bluetooth application prompts you to enter a pincode please follow the steps in Pincode Setup section 6 The scanner will emit two beeps as indication that the Bluetooth connection has established successfully 7 While conneted with the scanner as physical keyboard the touch keyboard on iOS Android device might disappear To resolve this issue please do the following 1 For iOS dev...

Page 21: ...f Bluetooth application prompts you to enter a pincode please follow the steps 1 Scan Pincode Start Pincode Start 2 Scan numeric barcodes below according to the pincode generated by the Bluetooth application 0 1 2 3 4 5 6 7 8 9 3 Scan Enter Enter ...

Page 22: ...SPP Slave the scanner will emit two beeps If host can t auto reconnect use BT SPP Master If host can auto reconnect use BT SPP Slave to avoid conflict BT SPP Master Auto reconnect BT SPP Slave No Auto reconnect 4 Select Wireless Scanner from discovered device list 5 If Bluetooth application prompts you to enter a pincode enter 1234 from the host 6 Enter serial communication software on your host a...

Page 23: ...e By default the pincode under BT SPP profile for the scanner is 1234 It is configurable up to 8 numbers Set SPP Pincode Example Set SPP Pincode to 0000 Step1 Scan Set SPP Pincode Step2 Scan 0 0 0 0 in Appendix Numbers Step3 Scan Set SPP Pincode ...

Page 24: ...Minute Default 03 Set Second Default 00 Example Set Power Off Timeout to 5 minnutes and 30 seconds Step1 Scan Set Minute Step2 Scan 0 5 in Appendix Numbers Step3 Scan Set Minute Step4 Scan Set Second Step5 Scan 3 0 in Appendix Numbers Step6 Scan Set Second To disable Power Off Timeout make scanner always on scan below barcode Disable Timeout Shut Down To shut down the scanner immediately pelase sc...

Page 25: ...a pincode will be requested by the host device which by default is 1234 for BT SPP profile and a random number generated by the host device for BT HID profile Enable SSP Disable SSP Batch Mode In Batch Mode data will be temporarily stored in memory buffer 2KB RAM when the scanner is out of range or in poor connection quality Once the scanner gets back in range the stored data will be sent back to ...

Page 26: ...ets Numbers Step 3 Scan Set Bluetooth Device ID To reset Bluetooth Device ID to Wireless Scanner scan below barcode Reset Bluetooth Device ID To add the last 6 digits of MAC address to Bluetooth Device ID Wireless xxxxxx scan below barcode Add MAC Address to Bluetooth Device ID Check Bluetooth Firmware Version To check scanner s Bluetooth firmware version please connect to a host device via BT HID...

Page 27: ... scan below configuration barcode Check Device MAC Address Check Host MAC Address To check scanner s MAC address please connect to a host device and scan below configuration barcode Check Host MAC Address Check Battery Life To check scanner s battery life please connect to a host device and scan below configuration barcode Check Battery Life ...

Page 28: ...ble of going through numerous setup procedures on the host device to establish connection Simply generate ScanLink barcode for the target slave device in below rule For BT HID profile please encode HID MAC Address in Code39 without checksum For BT SPP profile please encode SPP MAC Address in Code39 without checksum Example Target Slave Device MAC Address 00 15 83 52 2C 3B Profile BT HID Encode HID...

Page 29: ... file BARCODE txt to your computer To exit Memory Mode simply scan any interface barcode e g BT HID BT SPP Master Slave USB HID USB VCP other than memory mode Delete Last Record To delete last memory data please scan below barcode or press function button once when the scanner is in memory mode Delete Last Record Clear All Record To delete all memory data please connect the scanner to the host wit...

Page 30: ... Example Set Data Format as Barcode Data Date Time Step1 Scan Data Format Step2 Scan 4 3 2 respectively in Appendix Numbers Step3 Scan Data Format Field Separator The field separator in memory mode is comma by default It can be replaced by any alphanumeric characters Field Separator Example Set Field Separator as Semicolon Step1 Scan Field Separator Step2 Scan in Appendix Symbols Step3 Scan Field ...

Page 31: ... YYYY 03 DD MM YY 11 DD MM YY 04 MM DD YY 12 MM DD YY 05 YYYY MM DD 13 YYYY MM DD 06 YY MM DD 14 YY MM DD 07 DD MM 15 DD MM 08 MM DD 16 MM DD Example Set Date Format as MM DD YY Code 12 Step1 Scan Date Format Step2 Scan 1 2 respectively in Appendix Numbers Step3 Scan Date Format Time Format The default Time Format is HH MM SS Code 01 Time Format Below are available Time Format and their setup code...

Page 32: ...ctively in Appendix Numbers Step3 Scan Time Format Date Time Setup Set Date Set Time Example Set date as 2022 09 27 set time as 08 10 30 am HH MM SS Step1 Scan Set Date Step2 Scan 2 2 0 9 2 7 in Appendix Numbers Step3 Scan Set Date Step4 Scan Set Time Step5 Scan 0 8 1 0 3 0 in Appendix Numbers Step6 Scan Set Time ...

Page 33: ...comes an HID keyboard device USB HID USB VCP Scanning below configuration barcode will configure the scanner to USB VCP interface The scanner will be able communicate with the host via USB Virtual COM Normally virtual COM port can be recognized by the host If it is not recognizable by the host please download VCP driver from our website USB VCP ...

Page 34: ...abled Trigger Mode Toggle Mode In Toggle Mode the LED will stay on when the trigger is pressed once and will not turn off until a barcode is read or LED Auto Off timeout expires if LED Auto Off Control is enabled Toggle Mode Flash Mode In Flash Mode the LED will stay on after a barcode is detected and will start flashing if no barcode is detected after LED Auto Off timeout expires The trigger is u...

Page 35: ...led Continuous Mode Continuous Auto Off Mode In Continuous Auto Off Mode the LED will stay on when the trigger is pressed once and will automatically turn off if no barcode is detected after LED Auto Off timeout expires Continuous Auto Off Mode Flash Continuous Mode Trigger Control When enabled the LED can be turned on off by pressing trigger Trigger Control On Trigger Control Off ...

Page 36: ...ing duration When LED Auto Off Timeout expires the scanning operation stops automatically The configurable range is 0 1 125 sec 3 digits must be programmed during the multi step configuration 001 0 1 sec 002 0 2 sec 003 0 3 sec 004 0 4 sec 005 0 5 sec 0 6 1 sec 007 1 5 sec 008 2 0 sec 009 2 5 sec 010 3 sec 254 125 sec 255 unlimited LED Auto Off Timoeut Default 60 sec Example Set LED Auto Off Timeo...

Page 37: ... sec 254 125 sec 255 unlimited Identical Read Interval Default 1 sec Example Set Identical Read Interval as 5 sec Step1 Scan Identical Read Interval Step2 Scan 0 1 4 in Appendix Numbers Step3 Scan Identical Read Interval Accuracy Adjustment Accuracy Adjustment assures a more reliable decoded output The higher the number the greater the accuracy yet with slower speed The configurable range is 0 9 1...

Page 38: ...M ID is enabled a Factory ID or AIM ID see Appendix Factory ID and AIM ID Table will be added to the beginning of each barcode data When Set ID is enabled a user defined ID see Set ID will be added to the beginning of each barcode data Disable Code ID Enable Factory ID Enable AIM ID Enable Set ID Set ID Set ID can be 0 2 alphanumerics for each symbology Set ID Code39 Set ID Codabar ...

Page 39: ...Set ID EAN 13 Set ID EAN 8 Set ID UPC A Set ID UPC E Set ID Interleaved 2 of 5 Set ID Matrix 2 of 5 Set ID Industrial 2 of 5 Set ID Code93 Set ID Code11 Set ID MSI Plessey Set ID GS1 Databar Set ID GS1 Databar Limited Set ID GS1 Databar Expanded ...

Page 40: ...Set ID UK Plessey Set ID Telepen Set ID IATA Set ID GS1 128 Set ID Code32 Set ID IATA Example Set Code39 Set ID as XY Step1 Scan Set ID Code39 Step2 Scan X Y in Appendix Upper Case Alphabets Step3 Scan Set ID Code39 Data Length Send Data Length Off Send Data Length On ...

Page 41: ...ep 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Numbers Step 3 Scan Set Preamble Postamble Postamble can be up to 16 bytes of data Set Postamble Example Set Postamble as XYZ123 Step 1 Scan Set Postamble Step 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Numbers Step 3 Scan Set Postamble Clear Preamble Postamble Clear Preamble Postamble ...

Page 42: ...minator None LF CR CR LF TAB Space ESC Note 1 Default Terminator for BT HID or USB HID interface CR or Enter 2 Default Terminator for BT SPP or USB VCP interface CR LF 3 CR LF or LF is treated as Enter for BT HID or USB HID interface ...

Page 43: ...ies General Settings Enable All Symbologies Disable All Symbologies Note When all symbologies are disabled configuration barcodes are still readable UPC A Enable Disable UPC A Enable UPC A Disable UPC A Lead Digit Not Send Lead Digit Send Lead Digit ...

Page 44: ...Send Check Digit UPC A Expand to EAN 13 Enable UPC A Expand to EAN 13 Disable UPC A Expand to EAN 13 Add On Supplement Enable 5 digit Supplement Disable 5 digit Supplement Enable 2 digit Supplement Disable 2 digit Supplement Enable Add A Space Disable Add A Space ...

Page 45: ...ed Note When Addenda Required is enabled the scanner will only read an UPC A barcode that has 2 digit or 5 digit addenda supplement UPC E Enable Disable UPC E Enable UPC E Disable UPC E UPC E System Number UPC E0 Off UPC E1 Off UPC E0 On Only UPC E1 On Only UPC E0 On UPC E1 On ...

Page 46: ...t Not Send Lead Digit Send Lead Digit Check Digit Send Check Digit Not Send Check Digit UPC E Expand to UPC A Enable UPC E Expand to UPC A Disable UPC E Expand to UPC A Add On Supplement Enable 5 digit Supplement Disable 5 digit Supplement ...

Page 47: ...lement Disable 2 digit Supplement Enable Add A Space Disable Add A Space Enable Addenda Required Disable Addenda Required Note When Addenda Required is enabled the scanner will only read an UPC E barcode that has 2 digit or 5 digit addenda supplement ...

Page 48: ...ble Disable EAN 8 Enable EAN 8 Disable EAN 8 Lead Digit Not Send Lead Digit Send Lead Digit Check Digit Not Send Check Digit Send Check Digit EAN 8 Expand to EAN 13 Zero Extension Enable EAN 8 Expand to EAN 13 Disable EAN 8 Expand to EAN 13 ...

Page 49: ...igit Supplement Enable 2 digit Supplement Disable 2 digit Supplement Enable Add A Space Disable Add A Space Enable Addenda Required Disable Addenda Required Note When Addenda Required is enabled the scanner will only read an EAN 8 barcode that has 2 digit or 5 digit addenda supplement ...

Page 50: ...50 EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Lead Digit Not Send Lead Digit Send Lead Digit Check Digit Not Send Check Digit Send Check Digit Add On Supplement Enable 5 digit Supplement Disable 5 digit Supplement ...

Page 51: ... Add A Space Disable Add A Space Enable Addenda Required Disable Addenda Required Note When Addenda Required is enabled the scanner will only read an EAN 13 barcode that has 2 digit or 5 digit addenda supplement ISBN On Off Enable ISBN 10 Expand to ISBN 13 Disable ISBN 10 Expand to ISBN 13 ...

Page 52: ...ISBN ISSN ISMN will be considered as an extension of EAN 13 If ISBN ISSN ISMN needs to be read EAN 13 must be enabled If ISBN ISSN ISMN need to be read with addenda EAN 13 must be enabled with Addenda Required and 2 digit or 5 digit supplement enabled as well ...

Page 53: ... Length Default 05 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 54: ...nable AIM ID Disable AIM ID FUNC 1 Character Send FUNC1 Character Not Send FUNC1 Character Define FUNC1 Character Note 1 The first FUNC1 Character is transformed into c1 and the next FUNC1 Character s is transformed into GS by default which can be user defiend 2 Data format is as follows c1 Barcode Data GS Barcode Data ...

Page 55: ...bets Step3 Scan Define FUNC1 Character GS1 128 Min Max Length Set Min Length Default 05 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for GS1 128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 56: ...MT110L User s Manual V1 0 56 Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Not Send Start Stop Send Start Stop ...

Page 57: ...n Length Default 01 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code39 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 58: ...MT110L User s Manual V1 0 58 Code 32 Enable Disable Code 32 Enable Code 32 Disable Code 32 Leading Tailing Not Send Leading Tailing Send Leading Only Send Tailing Only Send Leading Tailing ...

Page 59: ...ength Default 06 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Code93 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 60: ...MT110L User s Manual V1 0 60 Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Verification Disable CDV CDV Send CD CDV Not Send CD Check Digit 1 Digit 2 Digits ...

Page 61: ... Default 32 Example Set Min Length as 8 Max Length as 12 for Code11 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 62: ...Disable Codabar Start Stop Send Start Stop Not Send Start Stop ST SP ABCD ABCD ST SP abcd abcd ST SP ABCD TN E ST SP abcd tn e Example of ST Start SP Stop 123456 Not Send Start Stop A123456B ST SP ABCD ABCD a123456b ST SP abcd acbd A123456N ST SP ABCD TN E a123456n ST SP abcd tn e ...

Page 63: ... Default 06 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Codabar Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 64: ...ta Off Set Insert Data Note 1 ABC Codabar American Blood Commission The ABC Code is an acronym for American Blood Commission This barcode is a variant of Codabar developed for the use in the blood bank This barcode consists of two barcodes which are decoded in one read cycle This barcode is concatenated when the stop character of the first barcode and the start character of the secnd barcode are b...

Page 65: ...r consists of two barcodes which are decoded in one read cycle The barcode is concatenated when the stop character of the first barcode is a C and the start character of the second barcode is a B These two characters are not transmitted 2 Please make sure Codabar Coupling is disabled before enabling CX Codabar Example Set Insert Data as X Step1 Scan Set Insert Data Step2 Scan X in Appendix Upper C...

Page 66: ...while in conjunction with Codabar Coupling enabled the data from any two Codabar barcodes can be coupled into one set of data without any limitations between the Stop Character of the first barcode and the Start Character of second barcode The Start and Stop characters associated with each barcode will be sent Example Set Insert Data as X Step1 Scan Set Insert Data Step2 Scan X in Appendix Upper C...

Page 67: ...aved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD First Last Digit Suppressed No Suppressed First Digit Suppressed Last Digit Suppressed ...

Page 68: ... Default 48 Example Set Min Length as 8 Max Length as 12 for Interleaved 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 69: ...TA Verification Disable CDV CDV Send CD CDV Not Send CD IATA Min Max Length Set Min Length Default 06 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for IATA Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length ...

Page 70: ... 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD ...

Page 71: ... Default 48 Example Set Min Length as 8 Max Length as 12 for Matrix 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 72: ... 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD Industrial 2 of 5 Min Max Length Set Min Length Default 06 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for Industrial 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length ...

Page 73: ...MT110L User s Manual V1 0 73 Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 74: ...a Postal Code Verification Disable CDV CDV Send CD CDV Not Send CD China Postal Code Min Max Length Set Min Length Default 11 Set Max Length Default 48 Example Set Min Length as 8 Max Length as 12 for China Postal Code Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length ...

Page 75: ...t Max Length Note Configurable range for Min Max Length is 01 99 MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Verification CDV Send CD CDV Not Send CD Check Digit Single Check Digit MOD10 Double Check Digits MOD10 Double Check Digits MOD10 MOD11 ...

Page 76: ... Default 48 Example Set Min Length as 8 Max Length as 12 for MSI Plessey Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 77: ...anual V1 0 77 UK Plessey Enable Disable UK Plessey Enable UK Plessey Disable UK Plessey Verification CDV Send CD CDV Not Send CD Telepen Enable Disable Telepen Enable Telepen Disable Telepen Output Format ASCII Number ...

Page 78: ... Enable Disable GS1 DataBar Enable GS1 DataBar Disable GS1 DataBar Enable Disable GS1 DataBar Stacked Omnidirectional Enable GS1 DataBar Stacked Disable GS1 DataBar Stacked Prefix AI Send Prefix AI Not Send Prefix AI Check Digit Send CD Not Send CD ...

Page 79: ...GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Limited Prefix AI Send Prefix AI Not Send Prefix AI Check Digit Send CD Not Send CD GS1 DataBar Expanded RSS Expanded Enable Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded Disable GS1 DataBar Expanded ...

Page 80: ...ed Min Max Length Set Min Length Default 01 Set Max Length Default 74 Example Set Min Length as 8 Max Length as 12 for GS1 DataBar Expanded Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Appendix Numbers Step6 Scan Set Max Length Note Configurable range for Min Max Length is 01 99 ...

Page 81: ...MT110L User s Manual V1 0 81 Chapter 7 Appendix Appendix Numbers 0 1 2 3 4 5 6 7 8 9 ...

Page 82: ...MT110L User s Manual V1 0 82 Appendix Upper Case Alphabets A B C D E F G H I J K L M N O P ...

Page 83: ...MT110L User s Manual V1 0 83 Q R S T U V W X Y Z ...

Page 84: ...MT110L User s Manual V1 0 84 Appendix Lower Case Alphabets a b c d e f g h i j k l m n o p ...

Page 85: ...MT110L User s Manual V1 0 85 q r s t u v w x y z ...

Page 86: ...MT110L User s Manual V1 0 86 Appendix Control Codes NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI ...

Page 87: ...MT110L User s Manual V1 0 87 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US ...

Page 88: ...MT110L User s Manual V1 0 88 Appendix Symbols _ ...

Page 89: ...MT110L User s Manual V1 0 89 ...

Page 90: ...MT110L User s Manual V1 0 90 SP DEL ...

Page 91: ...MT110L User s Manual V1 0 91 Appendix Function Keys F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App ...

Page 92: ...MT110L User s Manual V1 0 92 Appendix Navigation Keys Cursor Left Cursor Right Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del ...

Page 93: ...V1 0 93 Appendix Modifier Keys Alt Left make 1 Alt Left break Alt Right make Alt Right break Shift Left make 2 Shift Left break Shift Right make Shift Right break Win Left make Win Left break Win Right make Win Right break ...

Page 94: ...esume barcode setting 2 When Shift Left make is programmed please scan Shift Left break to resume barcode setting 3 When Ctrl Left make is programmed please scan Ctrl Left break to resume barcode setting Appendix Abort If there is an error reading data barcode during multi step configuration you may cancel configuration by scanning below configuration barcode Abort ...

Page 95: ...Key OFF Capslock Mode OFF Keyboard Layout English US Intercharacter Delay 4ms Interblock Delay 0ms BCC Binary Check Character OFF Image Settings Inverse Barcode OFF Interface Set SPP Pincode 1234 General Bluetooth Settings Power Off Timeout 03 00 Secure Simple Pairing SSP ON Batch Mode OFF Set Bluetooth Device ID Wireless Scanner Memory Mode Data Format Date Time Barcode Data Field Separator Date ...

Page 96: ...acy Adjustment 0 Data Format Code ID Disable Set ID N A Data Length OFF Preamble N A Postamble N A Terminator CR BT HID USB HID CR LF BT SPP USB VCP Symbologies General Settings N A UPC A Enable Disable ON Lead Digit Send Check Digit Send UPC A Expand to EAN 13 OFF 5 digit Supplement OFF 2 digit Supplement OFF Add A Space OFF Addenda Required ON UPC E Enable Disable ON System Number UPC E0 Only Le...

Page 97: ...sable ON Lead Digit Send Check Digit Send 5 digit Supplement OFF 2 digit Supplement OFF Add A Space OFF Addenda Required ON ISBN OFF ISBN 10 Expand to ISBN 13 OFF ISSN OFF ISMN OFF Code 128 Enable Disable ON Min Length 05 Max Length 48 GS1 128 Enable Disable ON AIM ID OFF FUNC1 Character Not Send Define FUNC1 GS Min Length 05 Max Length 48 Code 39 Enable Disable ON Verification Disable CDV Start S...

Page 98: ...isable ON Start Stop Not Send ST SP ABCD ABCD Verification Disable CDV Min Length 06 Max Length 48 CLSI Format OFF ABC Codabar OFF Insert Data On Off OFF Insert Data N A CX Codabar OFF Insert Data On Off OFF Insert Data N A Codabar Coupling OFF Insert Data On Off OFF Insert Data N A Interleaved 2 of 5 Enable Disable ON Verification Disable CDV First Last Digit Suppressed No Suppressed Min Length 0...

Page 99: ... Length 11 Max Length 48 MSI Plessey Enable Disable OFF Verification CDV Send CD Check Digit Single Check Digit MOD10 Min Length 06 Max Length 48 UK Plessey Enable Disable OFF Verification CDV Not Send CD Telepen Enable Disable OFF Output Format ASCII GS1 DataBar RSS 14 Enable Disable GS1 DataBar OFF Enable Disable GS1 DataBar Stacked Omnidirectional ON Prefix AI Not Send Check Digit Not Send CD G...

Page 100: ...MT110L User s Manual V1 0 100 RSS Expanded Enable Disable GS1 DataBar Expanded OFF Enable Disable GS1 DataBar Expanded Stacked ON Min Length 01 Max Length 74 ...

Page 101: ...igit Supplement Off UPC E 2 digit Supplement On UPC E 5 digit Supplement On E E0 E3 UPC A 2 digit 5 digit Supplement Off UPC A 2 digit Supplement On UPC A 5 digit Supplement On A E0 E3 EAN 13 2 digit 5 digit Supplement Off EAN 13 2 digit Supplement On EAN 13 5 digit Supplement On F E0 E3 Code 93 L G0 Code 11 Disable CDV J H0 Code 11 Send 1 Digit CD Code 11 Send 2 Digit CD H1 Code 11 Not Send CD H3...

Page 102: ...SCII Code 39 Disable CDV D A4 Full ASCII Code 39 CDV Send CD A5 Full ASCII Code 39 CDV Not Send CD A7 Code 39 Disable CDV M A0 Code 39 CDV Send CD A1 Code 39 CDV Not Send CD A3 IATA Standard 2 of 5 R R0 Industrial 2 of 5 V S0 China Postal Code Toshiba Code H X0 Interleaved 2 of 5 Disable CDV I I0 Interleaved 2 of 5 CDV Send CD I1 Interleaved 2 of 5 CDV Not Send CD I3 GS1 DataBar G E0 ...

Page 103: ... Line Feed 0B 11 VT Vertical Tab 0C 12 FF Form Feed 0D 13 CR Carriage Return 0E 14 SO Shift Out 0F 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1A 26 SUB Su...

Page 104: ...renthesis 2A 42 Asterisk 2B 43 Plus 2C 44 Comma 2D 45 Minus Dash 2E 46 Dot 2F 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3A 58 Colon 3B 59 Semi colon 3C 60 Less Than 3D 61 Equal Sign 3E 62 Greater Than 3F 63 Question Mark 40 64 AT Symbol 41 65 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4A 74 J ...

Page 105: ...V 57 87 W 58 88 X 59 89 Y 5A 90 Z 5B 91 Left Opening Bracket 5C 92 Back Slash 5D 93 Right Closing Bracket 5E 94 Caret Circumflex 5F 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6A 106 j 6B 107 k 6C 108 l 6D 109 m 6E 110 n 6F 111 o 70 112 p 71 113 q 72 114 r ...

Page 106: ...110L User s Manual V1 0 106 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7A 122 z 7B 123 Left Opening Brace 7C 124 Vertical Bar 7D 125 Right Closing Brace 7E 126 Tilde 7F 127 DEL Delete ...

Page 107: ...MT110L User s Manual V1 0 107 Version History Rev Date Description Issued 1 0 2022 07 28 Initial Release Shaw ...

Reviews: