background image

16

FILTER CONFIGURATION SUBMENU

False Colors

This monitor has a false color filter to aid in the setting of camera exposure. As the camera Iris is adjusted, elements of the
image will change color based on the luminance or brightness values. This enables proper exposure to be achieved without
the use of costly, complicated external equipment. To best utilize this feature, you must understand the color chart below

and have a basic understanding of camera exposure. Normally, when shooting subjects like people, it is common practice to
set exposure of faces to the equivalent of approximately 56 IRE. The false color filter will show this area as the color PINK on
the monitor. Therefore, as you increase exposure (open the IRIS), your subject will change color as indicated on the chart:

PINK, then GREY, then a few shades of YELLOW. Over exposed subjects (above 101 IRE) on the monitor will be shown as RED.
In addition, underexposed subjects will show as DEEP-BLUE to DARK–BLUE, with clipped-blacks indicated with a FUCHSIA-like
color. Lastly, the color GREEN is used to indicate elements of the image that are approximately 45 IRE. This represents a
‘neutral’ or ‘mid-level’ exposure commonly used for objects (not people).

17

False Color Key

Summary of Contents for V-MD185

Page 1: ...e warranty If there is no proof of purchase provided with a warranty claim Marshall Electronics reserves the right not to honor the warranty set forth above Therefore labor and parts may be charged to...

Page 2: ...2 31 Dimensions...

Page 3: ...C 30 W Voltage Requirement 12 VDC MECHANICAL Weight with rack ears 5 85 lbs Operating Temperature 32 F to 104 F 0 C to 40 C Storage Temperature 4 F to120 F 20 C to 50 C See Dimensions section for deta...

Page 4: ...that you wish to control with the GLOBAL CONTROL settings 4 Click on the POWER MENU or DISPLAY buttons that you wish to control Scan Network Use the Scan Network button to scan for any other Marshall...

Page 5: ...n If there is no module installed the text will read No Module v0 00 5 Installation and Initial Setup Unpacking Carefully unpack the V MD902 monitor and verify that the following items are included V...

Page 6: ...ode Default Gateway If you have selected the Manual configuration mode for the IP configuration mode you will be able to enter Default Gateway address manually in this field If you have selected DHCP...

Page 7: ...trol page to access all aspects of the physical keypad from the Network Control page Tally Tab Tally Use the Tally page in conjunction with the LAN100 tally source to control the LED and soft tally on...

Page 8: ...up Use this row to load any of the Setup configuration files available on the monitor This can be selected for each individual panel or on the global level under the GLOBAL column When selecting from...

Page 9: ...OSD Use this row set the Input Format OSD timeout length Curtain Color Use this row to set the current Curtain Color state Splash Screen Use this row to set the splash screen on each individual panel...

Page 10: ...b browser on your computer and take control We recommend Mozilla Firefox v7 0 and above for the best experience Note The Network Control page is designed to be consistent throughout the entire MD Seri...

Page 11: ...ateway for your monitor When in DHCP Configuration Mode this field will automatically be filled by the Default Gateway assigned by your network Host Name Use this field to enter a Host Name for your m...

Page 12: ...s of an image In Monochrome mode all color is disabled and only a grayscale image is shown In Blue Green and Red check field modes only the selected color will be shown Use the following procedure whe...

Page 13: ...brightness 8 Composite NTSC only Adjust the Tint button until the third bar from the left cyan and the third bar from the right magenta appear to match in brightness 9 Disable Blue Check Field mode Ra...

Page 14: ...This feature is not applicable to the V MD902 monitor Load Setup Select this menu item to reset all adjustments and menu settings to the factory default configuration or to one of the user configured...

Page 15: ...isable the Marshall Electronics Inc splash screen seen when the monitor is first powered on Freeze Use the Freeze function to freeze the current image on the screen Select this menu item again Unfreez...

Page 16: ...is common practice to set exposure of faces to the equivalent of approximately 56 IRE The false color filter will show this area as the color PINK on the monitor Therefore as you increase exposure ope...