14
System Configuration (continued)
Remote Control with Image Video Pass-Through
■
Overview
Use the following configuration for basic remote control of Marshall IMD series monitors, while also passing through
Image Video protocol. This setup allows remote control of the IMD monitor, and pass-through of Image Video text and
tally commands from an Image Video TSI-1000 or other Image Video protocol source.
■
Wiring Diagram
■
Monitor Configuration
The following settings are required on each IMD monitor:
IMD Protocol:
MEI-Image Video
IMD Baud Rate:
57600
ID#:
Each monitor’s ID# will be set automatically by Image Video controller.
IMD Name (S/N):
Each monitor must have a unique string in this field.
In this configuration, Pass-Through must be set to “ON” and to “Image Video” in the OSD Configuration & IMD
Page of the web interface. See page 19 for details.
Ethernet Cable to
Network Connection
on NCB-1004
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Marshall
IMD
Network
NCB-1004
Use second RS-422 jack on each monitor to
daisy-chain multiple monitors.
Image Video TSI-1000 Tally Controller
(Or other Image Video Protocol Source)
Connect up to 128
IMD screens per RS-
422 output
PC
Connect monitors to RS-422 Outputs on
Marshal IMD Monitors. Use up to 4 RS-422
outputs on NCB-1004.
Use 6P6C Modular Cable, wired pin-to-pin.