background image

         MPAAD User Manual  

If you land outside an airport unintentionally and find yourself at a markedly lower or higher 
height on your way back (

±

 10 m), turn the device off manually after arrival and then turn it 

on  again!  If  you  are  in  doubt,  proceed  in  the  same  way  to  be  on  the  safe  side!  This  will 
secure the proper re-calibration of the device prior to the next jump. 

 

5. 

Stand-by mode  

 

When  in  the  stand-by  mode,  the  device  is  on  the ground.  Pressure  and  a  possible  airplane 
start  are  checked  regularly.  This  mode  starts  as  soon  as  the  calibration  is  completed.  The 
display  shows  a  time  countdown  until  the  automatic  turning  off  of  the  machine.  For 
instance,  the  display  shows  time  information 

[  14:00  ]

  with  a  flickering  second-indicating 

colon in the middle. This indicates the introduction of the device into the stand-by mode for 
fourteen  hours  after  which  the  device  turns  off  automatically. All  the  time  the display  will 
continue  to  show  the  time  remaining  to  the  turn  off,  for  instance, 

[  14:00  ],  [ 13:59  ],  [ 

13:58 ], ……,     [ 00:01 ], [ 00:00 ]

.          

 
If  the  device  is  set  to a different mode than EXPERT, this is indicated on the display. The 
TANDEM  adjustment  is  indicated  by  letter 

‚t’

  in  the  far-right  display  field,  for  instance, 

[ 14:00t  ].

  The  BEGINNER  adjustment  is  indicated  by  letter 

‚b’, 

for instance, 

[ 14:00b ]. 

When the EXPERT adjustment is used, the far-right display field is empty. 

 

6. 

Jump mode  

 
Just a while after an airplane’s start the device automatically changes to a jump mode. The 
display  stops  imaging  time  and  shows  a  current  reached  height  above  the  ground  (AGL). 
After landing a calibration sequence takes place and the device automatically switches back 
to a standby mode. 
 
Note: 
Just a look at the display can check not only the mode in which the device is operating but 
also the time remaining to an automatic turn off as well as the proper function of the device.     

 

7. 

Adjustment during a jump outside an airport  

 

If the landing surface is located higher or lower than the starting place, the device has to be 
adjusted to a correct value as follows: 
If the device is on, turn it off. Activate the device by means of the activation sequence. As 
soon  as  the  display  begins  to  read 

[

 

ON ], 

press  the right  button 

( > ) 

and keep it pressed 

until  the  display starts to show 

[

 

SEt ]

. By pressing the right button or keeping it  pressed 

adjust  the  required  height  of  the  landing  ground  (

±

600  m).  Confirm  your  selection  by 

pressing the left button 

( o )

. Once the calibration has been completed, the device switches 

to  a  stand-by  mode.  The  display  shows,  in  turns,  a  time  countdown  and  a  set  height,  for 
instance, 

[ 14:00 ] …[ + 120 ] … [ 14:00 ]

 

PDF byl vytvo

ř

en zkušební verzí FinePrint pdfFactory 

www.fineprint.cz

Summary of Contents for MPAAD

Page 1: ...MPAAD User Manual 1 User Manual Automatic Securing Device MPAAD 4th Edition In Jev ko in 10 2004 PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Page 2: ...3 User menu 4 Main parts 5 Location of the device HEAD III Technical data HEAD IV Contents 1 Deactivated device 2 Device activation 3 Device deactivation 4 Calibration 5 Stand by mode 6 Jump mode 7 Ad...

Page 3: ...heck 3 Battery replacement 4 Chopping mechanism replacement 5 Device adjustment changes HEAD VII Service life and warranty conditions HEAD VIII Caution Placing the MPAAD securing device into a packing...

Page 4: ...agnetic interferences MPAAD is a modern electronic micro processor controlled securing device that does not require any special maintenance and that features several additional functions The device ca...

Page 5: ...tion takes place if the height above the ground is less than 270m and the fall rate is greater than 20 m s 1 The height lock is 450m TANDEM Activation takes place if the height above the ground is les...

Page 6: ...The lower compartment contains a battery The middle compartment contains a pyrotechnic chopping mechanism The battery and the chopping mechanism can be replaced 5 Location of the device The device is...

Page 7: ...evel AGL Activation height m 270 m Expert 270 m Beginner 560 m Tandem Activation rate m s 35 m s 1 Expert 20 m s 1 Beginner 35 m s 1 Tandem Height lock m 450 m Expert 450 m Beginner 900 m Tandem Accur...

Page 8: ...0 Subsequently automatic calibration takes place and CAL appears on the display Afterwards the machine switches to a stand by mode During the activation procedure MPAAD checks the battery chopping mec...

Page 9: ...djustment is indicated by letter b for instance 14 00b When the EXPERT adjustment is used the far right display field is empty 6 Jump mode Just a while after an airplane s start the device automatical...

Page 10: ...nu beginning 01 888o opening height during the last jump 02 888J total number of jumps 03 88 remaining battery capacity in percents 04 3 65v battery voltage in volts 05 888d battery age in days 06 41b...

Page 11: ...ounting of a MPAAD device into a parachute system HEAD VI Maintenance 1 Special maintenance The device does not require any special maintenance The device performs continual automatic checks battery i...

Page 12: ...connectors should be limited only to the necessary replacement of the battery Unnecessary repeated disconnecting may result in the deterioration of the electrical parameters of the connectors Battery...

Page 13: ...osely squashed flat so that the use of this side of the spanner for the screw tightening would be avoided Note Valid for the product dispatched from 08 2004 Check the device by turning it on 4 Choppin...

Page 14: ...o cartridge into the counterpart piece placed in the upper left part of the device body Place the pyro cartridge into the central part of the device so that its whole height sinks in the groove PDF by...

Page 15: ...ition The surface under the conductor is provided with glued on elastic rubber to insulate the cable Once the pyro cartridge has been replaced check the operation of the device by turning it on PDF by...

Page 16: ...the parachute airplane must not descend below the height of the landing ground If the positive re calibration of the landing ground is applied the airplane must not descend below the height of the la...

Page 17: ...a primary means for parachute opening The different use of the MPAAD device than is described in the operation manual may lead to its wrong function Considering a certain risk level that is an integra...

Page 18: ...MPAAD User Manual 18 Pilot parachute PV 038 The size of the device is 100 x 62 x 20 mm PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Page 19: ...4 5 the cord creates the surface with which the pad aligns onto the body of the pyro cartridge Completing The device must be completed by an authorized person First insert the cord and the pad into th...

Page 20: ...tion date __________________________________________________________ Reserve parachute type and size _____________________________________________ Production date _____________________________________...

Page 21: ...______________________________ Estimated activation height ________________________________________________ Air temperature on the ground ______________________________________________ How much time d...

Page 22: ...MPAAD User Manual 22 ________________________________________________________________________ PDF byl vytvo en zku ebn verz FinePrint pdfFactory www fineprint cz...

Reviews: