background image

 

TROUBLESHOOTING MOTOR 
 

To determine if the motor is  in  good  operating condition,  compare measured motor  resistance at the motor 
terminals to the values shown below. 

 

 

 

HIGH SPEED (1750) MEDIUM SPEED (1650) LOW SPEED (1450)

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

Black Motor Wire  & White 

Motor Wire

-

-

03-001

7190-1682

Fasco

Nema 1

1/6

115

1

11.5

-

-

03-002

7190-1903

Fasco

Nema 1

1/6

115

1

8.4

-

-

03-003

7190-1825

Fasco

Nema 1

1/6

230

1

64

-

-

03-004

7190-1904

Fasco

Nema 1

1/6

230

1

44.6

-

-

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

White Motor Wire (T1) 

Black Motor Wire (T3)

White Motor Wire (T1) 

Black Motor Wire (T5)

White Motor Wire (T1) 

Black Motor Wire (T2)

03-010

34G928X169

Baldor

Washdown (IP54)

1/2

115

1

1.2

-

-

03-010

34G928X169

Baldor

Washdown (IP54)

1/2

208/230

1

4.6

-

-

03-005

7124-1175

Genteq

Nema 1

1/2

115

1

2.6

3.8

5.2

03-006

7124-1560

Genteq

Nema 1

1/2

208/230

1

9.9

15.9

22.5

03-007

48S17T439

Marathon

Nema 1

1/2

277

1

7.7

-

-

03-005

K055PWM1736C13H

Nidec

Nema 1

1/2

115

1

2.1

3.7

5.2

03-005

K055PWM1736C13H

US

Nema 1

1/2

115

1

5.3

3.7

5.4

03-006

US

Nema 1

1/2

208/230

1

8.7

18.2

24.2

Applicable 

Air Curtain 

Series

Mars Part # Manufacturer Part #

Brand

Motor Rating

HP

Voltage

Phase

White Motor Wire (T1) 

Black Motor Wire (T2)

White Motor Wire (T1) 

Black Motor Wire (T3)

-

03-021

35T276R025G1

Baldor

Washdown (IP54)

1

115

1

0.7

-

-

03-015-Baldor

35M316S174

Baldor

Nema 1

1

115

1

0.6

-

-

03-015-Baldor

35M316S174

Baldor

Nema 1

1

208/230

1

2.2

-

-

03-021

35T276R025G1

Baldor

Washdown (IP54)

1

208/230

1

2.8

-

-

03-014

7124-0985

Genteq

Nema 1

1

115

1

1.6

2.4

-

03-015

7124-1096

Genteq

Nema 1

1

208/230

1

6.5

9.2

-

03-015

-

Nidec

Nema 1

1

208/230

1

4.3

6.5

-

03-014

K55BWJZB-2362

US

Nema 1

1

115

1

1

2.1

-

03-015

-

US

Nema 1

1

208/230

1

3.2

6.3

-

Black Motor Wire (L1) 

Red Motor Wire (L2)

Black Motor Wire (L1) 

White Motor Wire (L3)

Red Motor Wire (L2) 

White Motor Wire (L3)

03-008

P55YYDHB-1527

US

Nema 1

1/2

208-230

3

16.1

16.1

16.1

03-008

P55YYDHB-1527

US

Nema 1

1/2

460

3

63.6

63.6

63.6

03-009

48T17T135

Marathon

Nema 1

1/2

575

3

136

136

136

03-017

56T17T5541

Marathon

Nema 1

1

208-230

3

4.3

4.3

4.3

03-017

56T17T5541

Marathon

Nema 1

1

460

3

16.5

16.5

16.5

03-018

56T17T5544

Marathon

Nema 1

1

575

3

26.6

26.6

26.6

03-022

35N127S902

Baldor

Washdown (IP54)

1

208-230

3

5.1

5.1

5.1

03-022

35N127S902

Baldor

Washdown (IP54)

1

460

3

19.8

19.8

19.8

03-026

165716

Century

Nema 1

3

208-230

3

1.5

1.5

1.5

03-026

165716

Century

Nema 1

3

460

3

5.7

5.7

5.7

03-028

35E92Y26

Baldor

Nema 1

3

575

3

9.2

9.2

9.2

03-110

36H110-2211G1

Baldor

Nema 1

1,2,3

208-230

3

3.5

3.5

3.5

03-110

36H110-2211G1

Baldor

Nema 1

1,2,3

460

3

13.5

13.5

13.5

03-055

37F932W828G1

Baldor

Nema 1

5

230

3

0.7

0.7

0.7

03-055

37F932W828G1

Baldor

Nema 1

5

460

3

2.4

2.4

2.4

03-046

37F909X889G1

Baldor

Nema 1

7

230

3

0.6

0.6

0.6

03-046

37F909X889G1

Baldor

Nema 1

7

460

3

1.6

1.6

1.6

03-033

U639A - 215TTFC6027 Marathon

Nema 1

10

208-230

3

0.4

0.4

0.4

03-033

U639A - 215TTFC6027 Marathon

Nema 1

10

460

3

1.2

1.2

1.2

03-074

GT1128A 170118.60

Marathon

Nema 1

25

575

3

0.5

0.5

0.5

BD

HV2, NH2, 

PH12

EP2

WMI

WMH

STD2, N2, 

PH10, QP10

Applicable 

Air Curtain 

Series

Mars Part #

HP

Voltage

Brand

Motor Rating

Manufacturer Part #

Phase

LEAD WIRE OHM READINGS

MOTOR WIRES OR TERMINAL (T) OHM READINGS

Single Phase Motors

MARS MOTOR RESTANCE READINGS

Three Phase Motors

LPV2, LPN2

STD2, N2, 

PH10, QP10

HV2, NH2, 

PH12

Summary of Contents for LoPro 2 Series

Page 1: ...esign without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA LPV2...

Page 2: ...ithout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Co...

Page 3: ......

Page 4: ...ends without intermediate support up to 72 Models 84 to 144 require intermediate support in the center Adjustable air directional vane with 40 sweep front to back Standard color is Obsidian Black Rust...

Page 5: ......

Page 6: ...in power from circuit breaker at 115v 1MTR Door SW C NC LPV2 Wiring PUR BLK WHT YEL ORG GRN 1MTR Door SW C NC PUR BLK WHT YEL ORG GRN LPV2 LPN2 115V Unheated Wiring diagram with Door switch LPN2 Wirin...

Page 7: ...ower from circuit breaker at 208 230v 1MTR Door SW C NC LPV2 Wiring PUR WHT BLK ORG GRN 1MTR Door SW C NC PUR WHT BLK ORG GRN LPV2 LPN2 208 230V Unheated Wiring diagram with Door switch LPN2 Wiring YE...

Page 8: ...nged door type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical...

Page 9: ...6 STD SHOWN 3 Extended Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installa...

Page 10: ...stamped air intake screen s The LPV2 models can be configured with an aluminum mesh filter s as an option The LPN2 models 25 and all LPN F models come standard with an aluminum mesh air intake filter...

Page 11: ...l other accessories from interior of unit prior to operating Severe unit damage will occur if these items are not removed prior to operation 2 Lay unit on its top with directional vanes pointing up an...

Page 12: ...uing with the start up it is important to recognize the safety controls furnished with the unit WARNING The following items must all be completed by a qualified installer and checked off when complete...

Page 13: ...nimize condensation and freezing for freezer applications We recommend the air curtain unit to not replace doors but work in conjunction with door opening sequence cycle Contact factory for details CA...

Page 14: ...in this manual Obstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating be...

Page 15: ...ema 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Page 16: ...sponsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars liable for any...

Page 17: ...edestrian entrances B Air curtains for countertop and drive through windows 1 2 RELATED SECTIONS A Section 05 50 00 Metal Fabrications Concealed steel support members B Section 06 10 00 Rough Carpentr...

Page 18: ...Alloy Coated Galvannealed by the Hot Dip Process E AHRI 410 2001 Standard for Forced Circulation Air cooling and Air Heating Coils F NSF ANSI 37 Air Curtains for entranceways in food and food service...

Page 19: ...anufacturer s operation and maintenance manual including operation maintenance adjustment and cleaning instructions troubleshooting guide parts list and electrical wiring diagrams 1 5 QUALITY ASSURANC...

Page 20: ...ir over TEAO cooled motor with sealed lifetime pre lubricated ball bearings motor starter and thermal overload protection a LPN2 Units Wired for single speed operation b LPV2 Units Wired for variable...

Page 21: ...lows 1 UV UVC UVV germicidal and odor elimination 4 UV section with disposable UV bulbs 5 Discharge Provide integral discharge nozzle specified 6 Finish and Color Provide with no VOC corrosion resista...

Page 22: ...c Single Motor Fan Units LPV2 48 52 dBA d Single Motor Fan Units LPV2 60 LPV2 72 53 dBA e Two Motor Fan Units LPV2 84 LPV2 96 53 dBA f Two Motor Fan Units LPV2 108 LPV2 144 54 dBA D Insect Control Ai...

Page 23: ...Units LPV2 108 to LPV2 144 54 dBA 2 3 COMPONENTS A Electric Heaters Provide complete with motor control panel factory mounted to air curtain housing and thermostat to be field installed 1 Temperature...

Page 24: ...h to control air curtain s as follows Automatic on off control activates air curtain when door is opened and turns off when door is closed Provide limit switch for direct control one 1 HP or up to two...

Page 25: ...for the opening PART 3 EXECUTION 3 1 EXAMINATION A Verify that required utilities are in correct location and are of correct capacities for specified products B Verify openings to receive air curtain...

Page 26: ...performance on a calm day by measuring air temperature 6 inches off the floor Optimal reading is halfway between the temperature inside and outside the building 3 4 CLEANING A Clean air curtains prom...

Page 27: ...evisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Descriptio...

Reviews: